Microwave reflective biosensor for glucose level detection in aqueous solutions
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This article presents the design and analysis of a real-time non-invasive microwave microfluidic sensor for measuring glucose concentration in aqueous solutions. The sensor is made of an open-ended microstrip transmission line loaded with a complementary split-ring resonator (CSRR). The CSRR shows a very intense electric field concentration at resonance, which is highly sensitive to the dielectric sample loading. A microfluidic channel is designed to deliver the glucose solutions to the sensitive area of the device. By applying liquid samples to the channel, a resonance frequency shift is detectable in the reflection coefficient (S11) of the device. This in turn leads to a change in the |S11|. Both of the frequency shift and Δ|S11| can be used to measure the glucose level in the solution. Mathematical models are developed based on the measurement results of the glucose-water solutions using the resonance frequency shift and Δ|S11|. The developed sensing models are then used for detecting the glucose levels down to physiological values using the designed biosensor. The results prove the potential compatibility of the proposed biosensor for human glycaemia monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Liu, M., Liu, R., & Chen, W. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.02.010 · Cited by 747
Metamaterial-based microfluidic sensor for dielectric characterization
Withayachumnankul, W., Jaruwongrungsee, K., Tuantranont, A., Fumeaux, C., & Abbott, D. (2013) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2012.10.027 · Cited by 473
Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
Choi, H., Naylon, J., Luzio, S., Beutler, J., Birchall, J., Martin, C., & Porch, A. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2472019 · Cited by 312
Tang, H., Chen, J., Yao, S., Nie, L., Deng, G., & Kuang, Y. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.05.005 · Cited by 282
Integrated Broadband Microwave and Microfluidic Sensor Dedicated to Bioengineering
Grenier, K., Dubuc, D., Poleni, P.-E., Kumemura, M., Toshiyoshi, H., Fujii, T., & Fujita, H. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2034226 · Cited by 278
Metamaterial-Inspired Rotation Sensor With Wide Dynamic Range
Ebrahimi, A., Withayachumnankul, W., Al-Sarawi, S. F., & Abbott, D. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2313625 · Cited by 194
Self-citationMeasurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011) · Analytical Chemistry · doi:10.1021/ac201700c · Cited by 185
Horestani, A. K., Naqui, J., Shaterian, Z., Abbott, D., Fumeaux, C., & Martín, F. (2014) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2014.01.030 · Cited by 178
Microwave dielectric resonator biosensor for aqueous glucose solution
Kim, J., Babajanyan, A., Hovsepyan, A., Lee, K., & Friedman, B. (2008) · Review of Scientific Instruments · doi:10.1063/1.2968115 · Cited by 164
Kim, N., Dhakal, R., Adhikari, K. K., Kim, E., & Wang, C. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.10.021 · Cited by 129
Metamaterial-Inspired Multichannel Thin-Film Sensor
Withayachumnankul, W., Jaruwongrungsee, K., Fumeaux, C., & Abbott, D. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2173762 · Cited by 118
Adhikari, K. K., & Kim, N. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2503275 · Cited by 116
Temperature-Corrected Fluidic Glucose Sensor Based on Microwave Resonator
Jang, C., Park, J., Lee, H., Yun, G., & Yook, J. (2018) · Sensors · doi:10.3390/s18113850 · Cited by 101
Chretiennot, T., Dubuc, D., & Grenier, K. M. (2016) · Sensors · doi:10.3390/s16101733 · Cited by 93
Development of a sandwich format, amperometric screen-printed uric acid biosensor for urine analysis
Kanyong, P., Pemberton, R. M., Jackson, S. K., & Hart, J. P. (2012) · Analytical Biochemistry · doi:10.1016/j.ab.2012.05.027 · Cited by 60
Radio frequency based label-free detection of glucose
Park, H., Yoon, H. S., Patil, U. M., Anoop, R., Lee, J., Lim, J., Lee, W., & Jun, S. C. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.053 · Cited by 40
Fayaz, M., Lashaki, M. J., Abdolrazzaghi, M., Zarifi, M. H., Hashisho, Z., Daneshmand, M., Anderson, J. E., & Nichols, M. E. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.11.038 · Cited by 25
Chretiennot, T., Dubuc, D., & Grenier, K. M. (2014) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2014.6848570 · Cited by 24
Cited by
Noninvasive Glucose Sensing in Aqueous Solutions Using an Active Split-Ring Resonator
Abdolrazzaghi, M., Katchinskiy, N., Elezzabi, A. Y., Light, P. E., & Daneshmand, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3090050 · Cited by 207
Metadata
- Authors
- Ebrahimi, A., Scott, J., & Ghorbani, K.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 301
- Pages
- 111662
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2988264568
- Cited by
- 223
- References
- 19
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.