Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 312

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor

Open access
Choi, Heungjae, Naylon, Jack, Luzio, Steve, Beutler, Jan, Birchall, James, Martin, Chris, Porch, Adrian·2015·IEEE Transactions on Microwave Theory and Techniques

Abstract

A design of a microwave noninvasive continuous blood glucose monitoring sensor and its interference test results are presented. The novelty of the proposed sensor is that it comprises two spatially separated split-ring resonators, where one interacts with the change in glucose level of a sample under test while the other ring is used as a reference. The reference ring has a slightly different resonant frequency and is desensitized to the sample owing to its location, thus allowing changes in temperature to be calibrated out. From an oral glucose tolerance test with two additional commercially available sensors (blood strip and continuous glucose monitor) in parallel, we obtained encouraging performance for our sensor comparable with those of the commercial sensors. The effects of endogenous interferents common to all subjects, i.e., common sugars, vitamins (ascorbic acid), and metabolites (uric acid) have also been investigated by using a large Franz cell assembly. From the interference test, it is shown that the change in sensor response is dominated by changes in glucose level for concentrations relevant to blood, and the effects of interferents are negligible in comparison.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmtt.2015.2472019

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 32

  1. 10.1016/S0168-3659(01)00447-3 · DOI · Paper page
  2. 10.1111/1523-1747.ep12533356 · DOI · Paper page
  3. 10.1177/193229680900300438 · DOI · Paper page
  4. klein, 1983, Light Scattering in Solids I
  5. 10.1177/193229680700100403 · DOI
  6. schoemaker, 2014, CGM sensor design principles for reliable and accurate glucose monitoring in the subcutaneous tissue, 7th Int Adv Technol Treatments for Diabetes Conf
  7. 10.1109/TMTT.2009.2034226 · DOI · Paper page
  8. 10.1109/SAS.2008.4472932 · DOI
  9. 10.1109/MeMeA.2011.5966704 · doi:10.1109/memea.2011.5966704
  10. 10.1109/TMTT.2013.2250516 · DOI · Paper page
  11. 10.1109/TAP.2014.2313139 · DOI · Paper page
  12. siegel, 2014, Millimeter-wave non-invasive monitoring of glucose in anesthetized rats, Journal of Infrared Millimeter and Terahertz Waves, 1
  13. pack, 2003, The correlation of the complex dielectric constant and blood glucose at low frequency, Biosens Bioelectron, 19, 321, 10.1016/S0956-5663(03)00188-X · DOI
  14. khalil, 1999, Spectroscopic and clinical aspects of noninvasive glucose measurements, Clin Chem, 45, 165, 10.1093/clinchem/45.2.165 · DOI · Paper page
  15. 10.1088/0031-9155/41/11/002 · DOI · Paper page
  16. 10.2337/diacare.20.3.433 · DOI · Paper page
  17. 10.1109/IMWS-BIO.2014.7032398 · DOI
  18. 10.1038/73213 · DOI · Paper page
  19. 10.3390/diagnostics3040385 · DOI · Paper page
  20. behari, 2005, Microwave Dielectric Behavior of Wet Soil, 10.1007/1-4020-3288-9 · DOI
  21. chowdhury, 2014, Comparative performance between the former Glucowatch® and an improved non-invasive continuous glucose monitoring watch (CGM Watch™), 7th Int Adv Technol Treatments for Diabetes Conf
  22. dehennis, 2014, An integrated wireless fluorimeter for a long term implantable, continuous glucose monitoring system, 7th Int Adv Technol Treatments for Diabetes Conf
  23. 10.2337/diacare.27.5.1047 · DOI · Paper page
  24. gal, 2014, Calibration schemes of a truly non-invasive glucose monitor for variety of diabetics, 7th Int Ad Technol Treatments for Diabetes Conf
  25. 2015, 2014 annual report
  26. 10.1016/S0956-5663(03)00196-9 · DOI · Paper page
  27. 10.1109/TMTT.1984.1132619 · doi:10.1109/tmtt.1984.1132619
  28. 10.1109/TMTT.1983.1131661 · doi:10.1109/tmtt.1983.1131661
  29. 10.1109/TMTT.2014.2300066 · doi:10.1109/tmtt.2014.2300066
  30. 10.1109/TMTT.2014.2299514 · DOI
  31. 10.1007/0-306-48533-8_2 · doi:10.1007/0-306-48533-8_2
  32. 10.1063/1.4809823 · doi:10.1063/1.4809823

Cited by

See all 312

Metadata

Authors
Choi, H., Naylon, J., Luzio, S., Beutler, J., Birchall, J., Martin, C., & Porch, A.
Venue
IEEE Transactions on Microwave Theory and Techniques
Published
2015-10
Volume
63
Issue
10
Pages
3016-3025
ISSN
  • 0018-9480 (ISSN-L)
  • 1557-9670
OpenAlex
W1654139916
Cited by
312
References
1
FWCI
8.66
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor. https://app.cochat.ai/papers/10.1109/tmtt.2015.2472019
The paper
Choi, H., Naylon, J., Luzio, S., Beutler, J., Birchall, J., Martin, C., & Porch, A. (2015). Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor. IEEE Transactions on Microwave Theory and Techniques. https://doi.org/10.1109/tmtt.2015.2472019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.