The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
Open accessAbstract
A design of a microwave noninvasive continuous blood glucose monitoring sensor and its interference test results are presented. The novelty of the proposed sensor is that it comprises two spatially separated split-ring resonators, where one interacts with the change in glucose level of a sample under test while the other ring is used as a reference. The reference ring has a slightly different resonant frequency and is desensitized to the sample owing to its location, thus allowing changes in temperature to be calibrated out. From an oral glucose tolerance test with two additional commercially available sensors (blood strip and continuous glucose monitor) in parallel, we obtained encouraging performance for our sensor comparable with those of the commercial sensors. The effects of endogenous interferents common to all subjects, i.e., common sugars, vitamins (ascorbic acid), and metabolites (uric acid) have also been investigated by using a large Franz cell assembly. From the interference test, it is shown that the change in sensor response is dominated by changes in glucose level for concentrations relevant to blood, and the effects of interferents are negligible in comparison.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372
Research works printed but not linked: 32
- 10.1016/S0168-3659(01)00447-3 · DOI · Paper page
- 10.1111/1523-1747.ep12533356 · DOI · Paper page
- 10.1177/193229680900300438 · DOI · Paper page
- klein, 1983, Light Scattering in Solids I
- 10.1177/193229680700100403 · DOI
- schoemaker, 2014, CGM sensor design principles for reliable and accurate glucose monitoring in the subcutaneous tissue, 7th Int Adv Technol Treatments for Diabetes Conf
- 10.1109/TMTT.2009.2034226 · DOI · Paper page
- 10.1109/SAS.2008.4472932 · DOI
- 10.1109/MeMeA.2011.5966704 · doi:10.1109/memea.2011.5966704
- 10.1109/TMTT.2013.2250516 · DOI · Paper page
- 10.1109/TAP.2014.2313139 · DOI · Paper page
- siegel, 2014, Millimeter-wave non-invasive monitoring of glucose in anesthetized rats, Journal of Infrared Millimeter and Terahertz Waves, 1
- pack, 2003, The correlation of the complex dielectric constant and blood glucose at low frequency, Biosens Bioelectron, 19, 321, 10.1016/S0956-5663(03)00188-X · DOI
- khalil, 1999, Spectroscopic and clinical aspects of noninvasive glucose measurements, Clin Chem, 45, 165, 10.1093/clinchem/45.2.165 · DOI · Paper page
- 10.1088/0031-9155/41/11/002 · DOI · Paper page
- 10.2337/diacare.20.3.433 · DOI · Paper page
- 10.1109/IMWS-BIO.2014.7032398 · DOI
- 10.1038/73213 · DOI · Paper page
- 10.3390/diagnostics3040385 · DOI · Paper page
- behari, 2005, Microwave Dielectric Behavior of Wet Soil, 10.1007/1-4020-3288-9 · DOI
- chowdhury, 2014, Comparative performance between the former Glucowatch® and an improved non-invasive continuous glucose monitoring watch (CGM Watch™), 7th Int Adv Technol Treatments for Diabetes Conf
- dehennis, 2014, An integrated wireless fluorimeter for a long term implantable, continuous glucose monitoring system, 7th Int Adv Technol Treatments for Diabetes Conf
- 10.2337/diacare.27.5.1047 · DOI · Paper page
- gal, 2014, Calibration schemes of a truly non-invasive glucose monitor for variety of diabetics, 7th Int Ad Technol Treatments for Diabetes Conf
- 2015, 2014 annual report
- 10.1016/S0956-5663(03)00196-9 · DOI · Paper page
- 10.1109/TMTT.1984.1132619 · doi:10.1109/tmtt.1984.1132619
- 10.1109/TMTT.1983.1131661 · doi:10.1109/tmtt.1983.1131661
- 10.1109/TMTT.2014.2300066 · doi:10.1109/tmtt.2014.2300066
- 10.1109/TMTT.2014.2299514 · DOI
- 10.1007/0-306-48533-8_2 · doi:10.1007/0-306-48533-8_2
- 10.1063/1.4809823 · doi:10.1063/1.4809823
Cited by
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Strongly Enhanced Sensitivity in Planar Microwave Sensors Based on Metamaterial Coupling
Abdolrazzaghi, M., Daneshmand, M., & Iyer, A. K. (2018) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2018.2791942 · Cited by 353
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Metadata
- Authors
- Choi, H., Naylon, J., Luzio, S., Beutler, J., Birchall, J., Martin, C., & Porch, A.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2015-10
- Volume
- 63
- Issue
- 10
- Pages
- 3016-3025
- ISSN
- 0018-9480 (ISSN-L)
- 1557-9670
- OpenAlex
- W1654139916
- Cited by
- 312
- References
- 1
- FWCI
- 8.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor. https://app.cochat.ai/papers/10.1109/tmtt.2015.2472019
- The paper
- Choi, H., Naylon, J., Luzio, S., Beutler, J., Birchall, J., Martin, C., & Porch, A. (2015). Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor. IEEE Transactions on Microwave Theory and Techniques. https://doi.org/10.1109/tmtt.2015.2472019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.