A Minimized Valveless Electromagnetic Micropump for Microfluidic Actuation on Organ Chips
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Use of a microfluidic device allows control of perfusion flow in planar compartmentalized chambers and interconnection of two or more tissue cells via a microfluidic channel with an on-chip micropump.
“In contrast, the use of a microfluidic device allows the control of perfusion flow in the planar compartmentalized chambers and the interconnection of two or more tissue cells via a microfluidic channel with an on-chip micropump.12,13,16”
From Gut-liver-axis microphysiological system for studying cellular fluidic shear stress and inter-tissue interaction (2022) · cites this paper as [16]
Cites
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861 · see citing works
Wagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50234a · Cited by 476 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Yang, J., Hirai, Y., Imamura, S., Tsuchiya, T., Tabata, O., & Kamei, K.-I. (2022) · doi:10.1101/2022.01.31.478467 · Cited by 21 · see citing works
- Authors
- Mi, S., Pu, H., Xia, S., & Sun, W.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 301
- Pages
- 111704
- ISSN
- 0924-4247
- Cited by
- 60
- References
- 2
- Language
- en
- Funders
- Projects of Basic Research of Shenzhen, China (JCYJ20170817162629875, JCYJ20170412101508433, JCYJ20180507183655307)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review