The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
A dynamic multi-organ-chip for long-term cultivation and substance testing proven by 3D human liver and skin tissue co-culture
Open accessAbstract
Current in vitro and animal tests for drug development are failing to emulate the systemic organ complexity of the human body and, therefore, to accurately predict drug toxicity. In this study, we present a multi-organ-chip capable of maintaining 3D tissues derived from cell lines, primary cells and biopsies of various human organs. We designed a multi-organ-chip with co-cultures of human artificial liver microtissues and skin biopsies, each a (1)/100,000 of the biomass of their original human organ counterparts, and have successfully proven its long-term performance. The system supports two different culture modes: i) tissue exposed to the fluid flow, or ii) tissue shielded from the underlying fluid flow by standard Transwell® cultures. Crosstalk between the two tissues was observed in 14-day co-cultures exposed to fluid flow. Applying the same culture mode, liver microtissues showed sensitivity at different molecular levels to the toxic substance troglitazone during a 6-day exposure. Finally, an astonishingly stable long-term performance of the Transwell®-based co-cultures could be observed over a 28-day period. This mode facilitates exposure of skin at the air-liquid interface. Thus, we provide here a potential new tool for systemic substance testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“More recently, developers are increasingly starting to produce their chips from thermoplastic materials, already used in other biotechnological applications: polystyrene (Lee et al., 2018), poly(methyl methacrylate) (Busek et al., 2021), polycarbonate (Wagner et al., 2013), and cyclic olefin copolymer. While being amenable for cheaper and more scalable fabrication processes as well as providing”
From Recommendations on fit-for-purpose criteria to establish quality management for microphysiological systems and for monitoring their reproducibility (2024) · cites this paper as Wagner et al., 2013
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The metabolic activity and function of cells fluctuate over time and similar observations have been reported in the literature [61,62].”
From A liver-on-a-chip platform with bioprinted hepatic spheroids (2016) · cites this paper as [62]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
All About Albumin: Biochemistry, Genetics, and Medical Applications
Peters, T. (1995) · Thammasat University Digital Collections · Cited by 3,090
Capturing complex 3D tissue physiology in vitro
Griffith, L. G., & Swartz, M. A. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1858 · Cited by 2,290
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Infection of a human hepatoma cell line by hepatitis B virus
Gripon, P., Rumin, S., Urban, S., Le Seyec, J., Glaise, D., Cannie, I., Guyomard, C., Lucas, J., Trepo, C., & Guguen-Guillouzo, C. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.232137699 · Cited by 1,282
Perfused multiwell plate for 3D liver tissue engineering
Domansky, K., Inman, W., Serdy, J., Dash, A., Lim, M. H. M., & Griffith, L. G. (2010) · Lab Chip · doi:10.1039/b913221j · Cited by 444
Zhang, C., Zhao, Z., Abdul Rahim, N. A., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b915147h · Cited by 340
Sung, J. H., Esch, M. B., Prot, J.-M., Long, C. J., Smith, A., Hickman, J. J., & Shuler, M. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41017j · Cited by 233
Lübberstedt, M., Müller-Vieira, U., Mayer, M., Biemel, K. M., Knöspel, F., Knobeloch, D., Nüssler, A. K., Gerlach, J. C., & Zeilinger, K. (2011) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2010.04.013 · Cited by 227
Marx, U., Walles, H., Hoffmann, S., Lindner, G., Horland, R., Sonntag, F., Klotzbach, U., Sakharov, D., Tonevitsky, A., & Lauster, R. (2012) · Alternatives to Laboratory Animals · doi:10.1177/026119291204000504 · Cited by 177
Self-citationImura, Y., Sato, K., & Yoshimura, E. (2010) · Analytical Chemistry · doi:10.1021/ac100806x · Cited by 172
Research works printed but not linked: 1
- Ramachandran, 1999, Drug Metab. Dispos., 27, 1194
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Overcoming the challenges in administering biopharmaceuticals: Formulation and delivery strategies
Mitragotri, S., Burke, P. A., & Langer, R. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4363 · Cited by 1,702
Human organs-on-chips for disease modelling, drug development and personalized medicine
Ingber, D. E. (2022) · Nature Reviews Genetics · doi:10.1038/s41576-022-00466-9 · Cited by 1,589
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Self-citation
Metadata
- Authors
- Wagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., Lauster, R., & Marx, U.
- Affiliations
- Technische Universität Berlin (DE)
- Fraunhofer Institute for Material and Beam Technology (DE)
- BioClinicum (Russia) (RU)
- Research Institute of General Pathology and Pathophysiology, the Russian Academy of Medical Sciences (RU)
- Corresponding author
- Wagner, Ilka
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 18
- Pages
- 3538
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2087315598
- Cited by
- 476
- References
- 20
- Citations by year
- 2026: 11 · 2025: 19 · 2024: 32 · 2023: 29 · 2022: 38 · 2021: 33 · 2020: 40 · 2019: 36 · 2018: 56 · 2017: 54 · 2016: 46 · 2015: 38 · 2014: 34 · 2013: 9
- FWCI
- 23.37
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- DepositOnce (submittedVersion, public-domain)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Technische Universität Berlin – Universitätsbibliothek
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- multi-organ-on-a-chip, organ-on-a-chip, skin biopsy, long-term tissue culture, drug toxicity testing, troglitazone, tissue crosstalk, transwell culture, air-liquid interface, human skin
- MeSH terms
- Troglitazone, Cell Line, Cell Survival, Chromans, Humans, Liver, RNA, Skin, Biomass, Coculture Techniques, Thiazolidinediones, Microfluidic Analytical Techniques, Tissue Culture Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A dynamic multi-organ-chip for long-term cultivation and substance testing proven by 3D human liver and skin tissue co-culture. https://app.cochat.ai/papers/10.1039/c3lc50234a
- The paper
- Wagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., Lauster, R., & Marx, U. (2013). A dynamic multi-organ-chip for long-term cultivation and substance testing proven by 3D human liver and skin tissue co-culture. Lab on a Chip. https://doi.org/10.1039/c3lc50234a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.