Cited by 41Wireless Power Transfer SystemsInnovative Energy Harvesting TechnologiesWireless Body Area Networks

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Magnetoelectric wireless power transfer for biomedical implants: Effects of non-uniform magnetic field, alignment and orientation

Truong, Binh Duc, Andersen, Erik, Casados, Curtis, Roundy, Shad·2020·Sensors and Actuators A: Physical

Overview

Integrity signals

Registry

Crossref · 10.1016/j.sna.2020.112269

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 27 references

Research works printed but not linked: 2

  1. IEEE, IEEE standard for safety levels with respect to human exposure to electromagnetic fields, 0–3 kHz, IEEE Std C95.6-2002, 2002, pp. 1-0.
  2. IEEE, IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 kHz to 300 GHz, IEEE Std C95.1-2005 (Revision of IEEE Std C95.1-1991), 2006, pp. 1–238.

Cited by

Sorted by citations

See all 41

Metadata

Authors
Truong, B. D., Andersen, E., Casados, C., & Roundy, S.
Affiliations
University of Utah (US)
Corresponding author
Truong, Binh Duc
Venue
Sensors and Actuators A: Physical
Publisher
Elsevier BV
Published
2020-12
Volume
316
Pages
112269
ISSN
0924-4247 (ISSN-L)
OpenAlex
W3082192096
Cited by
41
References
27
Citations by year
2026: 7 · 2025: 4 · 2024: 6 · 2023: 6 · 2022: 9 · 2021: 9
FWCI
2.06
Type
journal article
Language
en
Open access
closed
Locations
Sensors and Actuators A Physical (publishedVersion)
Funders
National Science Foundation
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
biomedical implants, non-uniform magnetic field, receiver misalignment, receiver orientation, power transfer distance, magnetic flux density

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetoelectric wireless power transfer for biomedical implants: Effects of non-uniform magnetic field, alignment and orientation. https://app.cochat.ai/papers/10.1016/j.sna.2020.112269
The paper
Truong, B. D., Andersen, E., Casados, C., & Roundy, S. (2020). Magnetoelectric wireless power transfer for biomedical implants: Effects of non-uniform magnetic field, alignment and orientation. Sensors and Actuators A: Physical. https://doi.org/10.1016/j.sna.2020.112269