Surface Acoustic Wave (SAW) force myography sensor for muscle force output identification
Open accessIntegrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Real-time measurement of muscle strength has been proven to enhance both athletic performance and rehabilitation outcomes.
“Based on this feature, real-time measurement of muscle strength has been proven to enhance both athletic performance and rehabilitation outcomes (Fig. 5c) 95 , while sEMG sensors developed for amputees have also significantly improved prosthetic control capability (Fig. 5d) 92 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [95]
Cites
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695 · see citing works
Filtering the surface EMG signal: Movement artifact and baseline noise contamination
Luca, C. J. D., Gilmore, L., Kuznetsov, M., & Roy, S. H. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.027 · Cited by 1,289 · see citing works
Measurement of muscle contraction with ultrasound imaging
Hodges, P. W., Pengel, L. H. M., Herbert, R., & Gandevia, S. C. (2003) · Muscle & Nerve · doi:10.1002/mus.10375 · Cited by 814 · see citing works
Bohannon, R. W. (1997) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(97)90005-8 · Cited by 744 · see citing works
Wearable and Stretchable Strain Sensors: Materials, Sensing Mechanisms, and Applications
Souri, H., Banerjee, H., Jusufi, A., Radacsi, N., Stokes, A. A., Park, I., Sitti, M., & Amjadi, M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000039 · Cited by 691 · see citing works
A stretchable and biodegradable strain and pressure sensor for orthopaedic application
Boutry, C. M., Kaizawa, Y., Schroeder, B. C., Chortos, A., Legrand, A., Wang, Z., Chang, J., Fox, P., & Bao, Z. (2018) · Nature Electronics · doi:10.1038/s41928-018-0071-7 · Cited by 667 · see citing works
Ultra-sensitive and resilient compliant strain gauges for soft machines
Araromi, O. A., Graule, M. A., Dorsey, K. L., Castellanos, S., Foster, J. R., Hsu, W.-H., Passy, A. E., Vlassak, J. J., Weaver, J. C., Walsh, C. J., et al. (2020) · Nature · doi:10.1038/s41586-020-2892-6 · Cited by 513 · see citing works
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470 · see citing works
Assessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359 · see citing works
Surface Electromyography for Noninvasive Characterization of Muscle
Merletti, R., Rainoldi, A., & Farina, D. (2001) · Exercise and sport sciences reviews · doi:10.1097/00003677-200101000-00005 · Cited by 346 · see citing works
Kanoun, O., Bouhamed, A., Ramalingame, R., Bautista‐Quijano, J. R., Rajendran, D., & Al‐Hamry, A. (2021) · Sensors · doi:10.3390/s21020341 · Cited by 307 · see citing works
Chip-less wireless electronic skins by remote epitaxial freestanding compound semiconductors
Kim, Y., Suh, J. M., Shin, J. H., Liu, Y., Yeon, H., Qiao, K., Kum, H. S., Kim, C., Lee, H. E., Choi, C., et al. (2022) · Science · doi:10.1126/science.abn7325 · Cited by 293 · see citing works
SAW Sensors for Chemical Vapors and Gases
Devkota, J., Ohodnicki, P. R., & Greve, D. W. (2017) · Sensors · doi:10.3390/s17040801 · Cited by 281 · see citing works
Tutorial. Surface EMG detection in space and time: Best practices.
Merletti, R., & Muceli, S. (2019) · Journal of Electromyography & Kinesiology · doi:10.1016/j.jelekin.2019.102363 · Cited by 271 · see citing works
Kelln, B. M., McKeon, P. O., Gontkof, L. M., & Hertel, J. N. (2008) · Journal of Sport Rehabilitation · doi:10.1123/jsr.17.2.160 · Cited by 268 · see citing works
The basics of electromyography
Mills, K. R. (2005) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.069211 · Cited by 214 · see citing works
Jones, S. H., Chiesa, S. T., Chaturvedi, N., & Hughes, A. D. (2016) · Artery Research · doi:10.1016/j.artres.2016.09.001 · Cited by 187 · see citing works
The Utility of Isokinetic Dynamometry in the Assessment of Human Muscle Function
Gleeson, N., & Mercer, T. H. (1996) · Sports Medicine · doi:10.2165/00007256-199621010-00003 · Cited by 185 · see citing works
A Review of Force Myography Research and Development
Xiao, Z. G., & Menon, C. (2019) · Sensors · doi:10.3390/s19204557 · Cited by 171 · see citing works
Clinical use of objective measures of physical activity
Trost, S. G., & O'Neil, M. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093173 · Cited by 139 · see citing works
Mechanomyogram for Muscle Function Assessment: A Review
Islam, M. A., Sundaraj, K., Ahmad, R. B., & Ahamed, N. U. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058902 · Cited by 134 · see citing works
Baldwin, C. E., Paratz, J. D., & Bersten, A. D. (2012) · Journal of Critical Care · doi:10.1016/j.jcrc.2012.03.001 · Cited by 133 · see citing works
A Piezoresistive Sensor to Measure Muscle Contraction and Mechanomyography
Esposito, D., Andreozzi, E., Fratini, A., Gargiulo, G. D., Savino, S., Niola, V., & Bifulco, P. (2018) · Sensors · doi:10.3390/s18082553 · Cited by 127 · see citing works
Biomechanical Evaluation of Movement in Sport and Exercise
(2007) · Routledge eBooks · doi:10.4324/9780203935750 · Cited by 111 · see citing works
Beck, T. W., Housh, T. J., Johnson, G. O., Weir, J. P., Cramer, J. T., Coburn, J. W., & Malek, M. H. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.08.007 · Cited by 106 · see citing works
The Various Oximetric Techniques Used for the Evaluation of Blood Oxygenation
Nitzan, M., Nitzan, I., & Arieli, Y. S. (2020) · Sensors · doi:10.3390/s20174844 · Cited by 99 · see citing works
Surface Electromyography Applied to Gait Analysis: How to Improve Its Impact in Clinics?
Agostini, V., Ghislieri, M., Rosati, S., Balestra, G., & Knaflitz, M. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00994 · Cited by 97 · see citing works
Surface Electromyography (EMG) Signal Processing, Classification, and Practical Considerations
Phinyomark, A., Campbell, E., & Scheme, E. (2019) · Series in bioengineering · doi:10.1007/978-981-13-9097-5_1 · Cited by 96 · see citing works
Relationships between surface-detected EMG signals and motor unit activation
Suzuki, H., CONWIT, R. A., Stashuk, D. W., SANTARSIERO, L., & Metter, E. J. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200209000-00018 · Cited by 88 · see citing works
Multiple-Joint Isokinetic Dynamometry: A Critical Review
Dvir, Z., & Müller, S. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002982 · Cited by 88 · see citing works
Flexible surface acoustic wave strain sensor based on single crystalline LiNbO3 thin film
Xu, H., Dong, S., Xuan, W., Farooq, U., Huang, S., Li, M., Wu, T., Jin, H., Wang, X., & Luo, J. (2018) · Applied Physics Letters · doi:10.1063/1.5021663 · Cited by 80 · see citing works
A textile magnetoelastic patch for self-powered personalized muscle physiotherapy
Xu, J. H., Tat, T., Yin, J., Ngo, D., Zhao, X., Wan, X., Che, Z., Chen, K., Harris, L., & Chen, J. (2023) · Matter · doi:10.1016/j.matt.2023.06.008 · Cited by 75 · see citing works
Development of a wireless and passive temperature-compensated SAW strain sensor
Wang, W., Xue, X., Fan, S., Liu, M., Liang, Y. F., & Lu, M. (2020) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2020.112015 · Cited by 72 · see citing works
Flexible and wearable acoustic wave technologies
Zhou, J. W., Guo, Y., Wang, Y., Ji, Z., Zhang, Q., Zhuo, F., Luo, J., Tao, R., Xie, J., Reboud, J., et al. (2023) · Applied Physics Reviews · doi:10.1063/5.0142470 · Cited by 64 · see citing works
Paredes‐Madrid, L., Matute, A., Quintero, J. O. B., Vargas, C. A. P., & Velásquez, E. I. G. (2017) · Materials · doi:10.3390/ma10111334 · Cited by 59 · see citing works
Towards Soft Wearable Strain Sensors for Muscle Activity Monitoring
Alvarez, J. T., Gerez, L. F., Araromi, O. A., Hunter, J. G., Choe, D. K., Payne, C. J., Wood, R. J., & Walsh, C. J. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3196501 · Cited by 57 · see citing works
Flexible surface acoustic wave respiration sensor for monitoring obstructive sleep apnea syndrome
Jin, H., Tao, X., Dong, S., Qin, Y., Yu, L., Luo, J., & Deen, M. J. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa8ae0 · Cited by 56 · see citing works
Test-Retest Reliability of Isokinetic Strength Measurements in Lower Limbs in Elderly
Parraça, J. A., Adsuar, J. C., Domínguez‐Muñoz, F. J., My works are correct, B. M. I. A. A. I. S. R. L. M. T. I. D. A.-M., & Tomás-Carús, P. (2022) · Biology · doi:10.3390/biology11060802 · Cited by 51 · see citing works
Ji, Z., Zhou, J. W., Lin, H., Wu, J., Zhang, D., Garner, S., Gu, Y. A., Dong, S., Fu, Y., & Duan, H. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00325-3 · Cited by 50 · see citing works
Static and cyclic performance evaluation of sensors for human interface pressure measurement
Dabling, J. G., Filatov, A., & Wheeler, J. W. (2012) · doi:10.1109/embc.2012.6345896 · Cited by 50 · see citing works
Qi, L., Wakeling, J. M., Green, A., Lambrecht, K., & Ferguson-Pell, M. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2010.09.006 · Cited by 47 · see citing works
Swanson, E. C., Weathersby, E. J., Cagle, J. C., & Sanders, J. E. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4043561 · Cited by 46 · see citing works
Fatigue and the Electromechanical Efficiency of the Vastus Medialis and Vastus Lateralis Muscles
Ebersole, K. T., & Malek, D. M. (2008) · Journal of Athletic Training · doi:10.4085/1062-6050-43.2.152 · Cited by 39 · see citing works
Monitoring elbow isometric contraction by novel wearable fabric sensing device
Wang, X., Tao, X., So, R. C. H., Shu, L., Yang, B., & Li, Y. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/125022 · Cited by 37 · see citing works
2008 IEEE International Ultrasonics Symposium
(2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.707 · Cited by 34 · see citing works
A Flexible Wireless sEMG System for Wearable Muscle Strength and Fatigue Monitoring in Real Time
Gong, Q., Jiang, X., Liu, Y., Yu, M., & Hu, Y. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202200916 · Cited by 33 · see citing works
Novel force myography sensor to measure muscle contractions for controlling hand prostheses
Prakash, A., Sharma, N., & Sharma, S. (2019) · Instrumentation Science & Technology · doi:10.1080/10739149.2019.1655441 · Cited by 30 · see citing works
Flexible Strain Sensor Based on Ultra-Thin Quartz Plate
Feng, B., Jin, H., Fang, Z., Yu, Z., Dong, S., & Luo, J. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3088473 · Cited by 28 · see citing works
Relationship between Isometric Muscle Force and Fractal Dimension of Surface Electromyogram
Beretta-Piccoli, M., Boccia, G., Ponti, T., Clijsen, R., Barbero, M., & Cescon, C. (2018) · BioMed Research International · doi:10.1155/2018/5373846 · Cited by 27 · see citing works
Nazmi, N., Rahman, M. A. A., Mazlan, S. A., Zamzuri, H., & Mizukawa, M. (2015) · doi:10.1109/icobe.2015.7235878 · Cited by 27 · see citing works
Integrated Optical Fiber Force Myography Sensor as Pervasive Predictor of Hand Postures
Wu, Y. T., Gomes, M. K., da Silva, W. H., Lazari, P. M., & Fujiwara, E. (2020) · Biomedical Engineering and Computational Biology · doi:10.1177/1179597220912825 · Cited by 26 · see citing works
Continuous monitoring of upper-limb activity in a free-living environment: a validation study
Vega‐González, A., Bain, B., Dall, P., & Granat, M. H. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0233-7 · Cited by 25 · see citing works
Ma, R., Liu, W., Sun, X., Zhou, S., & Lin, D. (2022) · Micromachines · doi:10.3390/mi13020202 · Cited by 25 · see citing works
Error compensation in force sensing resistors
Velásquez, E. I. G., Gómez, V., Paredes‐Madrid, L., & Colorado, H. A. (2019) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2019.100300 · Cited by 24 · see citing works
2012 IEEE International Frequency Control Symposium Proceedings
(2012) · doi:10.1109/fcs19086.2012 · Cited by 22 · see citing works
Tsiros, M. D., GRIMSHAW, P. N., SHIELD, A. J., & Buckley, J. D. (2011) · Work · doi:10.3233/wor-2011-1162 · Cited by 21 · see citing works
Flexible Capacitive Sensing and Ultrasound Calibration for Skeletal Muscle Deformations
Guo, J., Guo, C., Zhou, J., Duan, K., & Wang, Q. (2022) · Soft Robotics · doi:10.1089/soro.2022.0065 · Cited by 21 · see citing works
A novel integrated mechanomyogram-vocalization access solution
Alves, N., Falk, T. H., & Chau, T. T. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.06.003 · Cited by 19 · see citing works
Morin, M., Duchesne, É., Bernier, J., Blanchette, P., Langlois, D., & Hébert, L. J. (2021) · Archives of Rehabilitation Research and Clinical Translation · doi:10.1016/j.arrct.2021.100172 · Cited by 18 · see citing works
Zuñiga, J. M., Housh, T. J., Camic, C. L., Hendrix, C. R., Mielke, M. M., Schmidt, R. J., & Johnson, G. O. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2010.01.001 · Cited by 16 · see citing works
Schasfoort, F. C., Bussmann, J. B. J., Martens, W. L. J., & Stam, H. J. (2006) · Behavior Research Methods · doi:10.3758/bf03192798 · Cited by 16 · see citing works
Evaluation of Optical Myography Sensor as Predictor of Hand Postures
Wu, Y. T., Fujiwara, E., & Suzuki, C. K. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2905229 · Cited by 15 · see citing works
Petrone, N., Costa, G., Foscan, G., Gri, A., Mazzanti, L., Migliore, G., & Cutti, A. G. (2020) · Sensors · doi:10.3390/s20205758 · Cited by 15 · see citing works
Wang, T., Zhao, Y., & Wang, Q. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3287729 · Cited by 15 · see citing works
Yue, X. A., Kiely, J., Luxton, R. W., Chen, B., McLeod, C. N., & Drakakis, E. M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3136705 · Cited by 13 · see citing works
Miyake, T., Minakuchi, T., Sato, S., Okubo, C., Yanagihara, D., & Tamaki, E. (2024) · Sensors · doi:10.3390/s24041108 · Cited by 13 · see citing works
MMG-torque estimation under dynamic contractions
Lei, K. F., Tsai, W., Lin, W., & Lee, M. (2011) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2011.6083774 · Cited by 12 · see citing works
A Wireless, Passive Magnetoelastic Force–Mapping System for Biomedical Applications
Pereles, B. D., DeRouin, A. J., & Ong, K. G. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025880 · Cited by 12 · see citing works
Surface‐Level Muscle Deformation as a Correlate for Joint Torque
Alvarez, J. T., de Marcillac, A., Jin, Y., Gerez, L. F., Araromi, O. A., & Walsh, C. J. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202400444 · Cited by 11 · see citing works
Acute patellar dislocation during eccentric muscle testing on the Biodex dynamometer
Maletius, W., Gillquist, J., & Messner, K. (1994) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(05)80203-8 · Cited by 10 · see citing works
Myers, B. J. (2020) · Isokinetics and Exercise Science · doi:10.3233/ies-201150 · Cited by 9 · see citing works
Flexible UV sensor based on nanostructured ZnO thin film SAW device
Hasan, S. A., Torun, H., Gibson, D., Wu, Q., Cooke, M. D., & Fu, Y. (2019) · IEEE Jordan International Joint Conference on Electrical Engineering and Information Technology (JEEIT) · doi:10.1109/jeeit.2019.8717373 · Cited by 9 · see citing works
Surface Acoustic Wave (SAW) Sensors for Cryogenic Temperature and Strain Sensing
Furniss, J., Carka, D., Voiculescu, I., Lee, K.-L., Xiang, D., & Li, F. (2018) · IEEE International Conference on Wireless for Space and Extreme Environments (WiSEE) · doi:10.1109/wisee.2018.8637326 · Cited by 8 · see citing works
Self-citationSurface Acoustic Wave Sensors for Temperature and Strain Measurements
Yang, Y., Wang, Y., Carka, D., & Li, F. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251505 · Cited by 7 · see citing works
Self-citationIslam, M. R. U., & Bai, S. (2022) · Biomedical Engineering Advances · doi:10.1016/j.bea.2022.100062 · Cited by 6 · see citing works
Place of the gold standard isokinetic dynamometer in Paralympic sports: a systematic review
Ahmadi, S., & Uchida, M. C. (2021) · Human Movement · doi:10.5114/hm.2021.100319 · Cited by 5 · see citing works
Tucker, D. Y. G., Solie, L. P., & Hines, J. (2012) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2012.6243725 · Cited by 4 · see citing works
Flexible Surface Acoustic Wave (SAW) Sensors for Cryogenic Sensing Application
Kohler, M., Zhang, A., Moore, C., Voiculescu, I., & Li, F. (2023) · doi:10.1115/imece2023-113741 · Cited by 3 · see citing works
Self-citationDean, J. M., Murton, A. J., Glover, S. Q., Gutierrez, I. L., Andersen, C. R., Herndon, D. N., Lee, J. O., & Suman-Vejas, O. E. (2019) · Journal of Burn Care & Research · doi:10.1093/jbcr/irz003 · Cited by 2 · see citing works
Temperature measurement of power electronics devices based on SAW sensors
Błaszczyk, P. M., Wojcik, M., & Baszynski, M. (2014) · IEEE International Conference on Emerging Technologies and Factory Automation (ETFA) · doi:10.1109/etfa.2014.7005085 · Cited by 1 · see citing works
Flagged first, then by citations
2 of the 84 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Chen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9 · see citing works
Gou, J., Fu, X., & Xu, Z. (2026) · Sensors and Actuators Reports · doi:10.1016/j.snr.2026.100501 · Cited by 1 · see citing works
Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque
Kohler, M. C., Rothstein, A., Greenberg, E. T., Voiculescu, I., Tiwale, N. M., & Li, F. (2026) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2026.100974
Self-citationLi, F., Hou, X., Zhang, X., Zhao, H., Gao, W., Hu, S., Wang, Z., Geng, W., He, J., & Chou, X. (2026) · Science China Information Sciences · doi:10.1007/s11432-025-4871-2
Self-citationAn Integrated Fabric‐Pneumatic Soft Sensing System for Multi‐Site Muscle Activity Decoding
Xun, Q., Ambrose, J. W., Xiong, Q., & Yeow, C. (2026) · Advanced Intelligent Systems · doi:10.1002/aisy.70545
- Authors
- Kohler, M. C., Voiculescu, I., & Li, F.
- Affiliations
- New York Institute of Technology (US)
- City College of New York (US)
- Corresponding author
- Li, Fang
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2024-12
- Volume
- 380
- Pages
- 115959
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W4403913747
- Cited by
- 5
- References
- 84
- Citations by year
- 2026: 5
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- green
- dx.doi.org
- Licence
- Locations
- Sensors and Actuators A Physical (publishedVersion)
- SSRN Electronic Journal (acceptedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Acoustic Wave Resonator Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- surface acoustic wave sensors, force myography, muscle force measurement, muscle contraction detection, self-powered wireless sensors, electromyography comparison, strain gauge comparison, prosthetic control, exoskeleton control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review