The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
A review of fiber-optic biosensors
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1991) · Topics in Lightwave Transmission Systems · doi:10.1016/b978-0-12-447302-7.50001-0 · Cited by 1,162
Biosensors in clinical chemistry
D'Orazio, P. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00241-9 · Cited by 524
Sharma, A. K., & Gupta, B. D. (2005) · Optics Communications · doi:10.1016/j.optcom.2004.10.013 · Cited by 195
Quantification of Cytokines Involved in Wound Healing Using Surface Plasmon Resonance
Battaglia, T. M., Masson, J., Sierks, M. R., Beaudoin, S. P., Rogers, J. M., Foster, K. N., Holloway, G. A., & Booksh, K. S. (2005) · Analytical Chemistry · doi:10.1021/ac050568w · Cited by 115
Detection of Cytochrome c in a Single Cell Using an Optical Nanobiosensor
Song, J. M., Kasili, P. M., Griffin, G. D., & Vo‐Dinh, T. (2004) · Analytical Chemistry · doi:10.1021/ac0352878 · Cited by 74
Detection of Protein A Produced byStaphylococcus aureuswith a Fiber-optic-based Biosensor
Chang, Y. H., Chang, T. C., Kao, E., et al. (1996) · Bioscience Biotechnology and Biochemistry · doi:10.1271/bbb.60.1571 · Cited by 41
Leung, A., Shankar, P. M., & Mutharasan, R. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.10.056 · Cited by 39
Self-citationA fibre-optic biosensor for detection of microbial contamination
Almadidy, A., Watterson, J. H., Piunno, P. A. E., Foulds, I. V., Horgen, P. A., & Krull, U. J. (2003) · Canadian Journal of Chemistry · doi:10.1139/v03-070 · Cited by 25
Detection of trophic factor activated signaling molecules in cells by a compact fiber-optic sensor
Kapoor, R., Kaur, N., Nishanth, E. T., Halvorsen, S. W., Bergey, E. J., & Prasad, P. N. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.02.004 · Cited by 19
Cited by
A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors
Naresh, V., & Lee, N. (2021) · Sensors · doi:10.3390/s21041109 · Cited by 2,066
Advances in biosensors: Principle, architecture and applications
Perumal, V., & Hashim, U. (2014) · Journal of Applied Biomedicine · doi:10.1016/j.jab.2013.02.001 · Cited by 606
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2008) · Analytical Chemistry · doi:10.1021/ac800473b · Cited by 571
Disposable Nucleic Acid Biosensors Based on Gold Nanoparticle Probes and Lateral Flow Strip
Mao, X., Ma, Y., Zhang, A., Zhang, L., Zeng, L., & Liu, G. (2009) · Analytical Chemistry · doi:10.1021/ac8024653 · Cited by 344
Optical Fiber Sensors: Working Principle, Applications, and Limitations
Elsherif, M., Salih, A. E., Muñoz, M. G., Alam, F., AlQattan, B., Antonysamy, D. S., Zaki, M. F., Yetisen, A. K., Park, S., Wilkinson, T. D., et al. (2022) · Advanced Photonics Research · doi:10.1002/adpr.202100371 · Cited by 330
Metadata
- Authors
- Leung, A., Shankar, P. M., & Mutharasan, R.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2007-08
- Volume
- 125
- Issue
- 2
- Pages
- 688-703
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2102243166
- Cited by
- 693
- References
- 9
- FWCI
- 20.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.