The DOI matches its Crossref record.
Copper oxide nanoparticle impurities are responsible for the electroanalytical detection of glucose seen using multiwalled carbon nanotubes
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advancements in Pt and Pt-free catalysts for oxygen reduction reaction
Nie, Y., Li, L., & Wei, Z. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00484a · Cited by 2,156
Electrochemistry of Graphene and Related Materials
Ambrosi, A., Chua, C. K., Bonanni, A., & Pumera, M. (2014) · Chemical Reviews · doi:10.1021/cr500023c · Cited by 1,208
Graphene for electrochemical sensing and biosensing
Pumera, M., Ambrosi, A., Bonanni, A., Chng, E. L. K., & Poh, H. L. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.05.011 · Cited by 1,199
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
Self-citationA Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
“Recently, the existence of CuO nanoparticles as impurities in a CNT-based electrode has been claimed to be responsible for electrocatalytic activity of glucose oxidation [117] as the synthetic”
BackgroundJiang, L.-C., & Zhang, W.-D. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.10.038 · Cited by 667
Zhou, M., Wang, H.-L., & Guo, S. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00414d · Cited by 665
Non-enzymatic electrochemical sensing of glucose
Wang, G., He, X., Wang, L., Gu, A., Huang, Y., Fang, B., Geng, B., & Zhang, X. (2013) · Microchimica Acta · doi:10.1007/s00604-012-0923-1 · Cited by 522
Nanostructured copper oxide semiconductors
Zoolfakar, A. S., Rani, R. A., Morfa, A. J., O'Mullane, A. P., & Kalantar‐Zadeh, K. (2014) · Refubium (Universitätsbibliothek der Freien Universität Berlin) · doi:10.17169/refubium-19959 · Cited by 448
The use of nanoparticles in electroanalysis: an updated review
Campbell, F. W., & Compton, R. G. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3063-7 · Cited by 409
Self-citationNonenzymatic electrochemical glucose sensor based on MnO2/MWNTs nanocomposite
Chen, J., Zhang, W.-D., & Ye, J.-S. (2008) · Electrochemistry Communications · doi:10.1016/j.elecom.2008.06.022 · Cited by 408
The Electrochemistry of Carbon Nanotubes: Fundamentals and Applications
Pumera, M. (2009) · Chemistry – A European Journal · doi:10.1002/chem.200900421 · Cited by 376
Wang, L., Ambrosi, A., & Pumera, M. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201309171 · Cited by 367
Metal oxide based non-enzymatic electrochemical sensors for glucose detection
Dong, Q., Ryu, H., & Lei, Y. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.137744 · Cited by 338
Metadata
- Authors
- Batchelor-McAuley, C., Wildgoose, G. G., Compton, R. G., Shao, L., & Green, M. L. H.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2008-05
- Volume
- 132
- Issue
- 1
- Pages
- 356-360
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2025361023
- Cited by
- 173
- References
- 0
- FWCI
- 14.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.