The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Cu-Ag bimetallic nanoparticles on reduced graphene oxide nanosheets as peroxidase mimic for glucose and ascorbic acid detection
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preparation of Graphitic Oxide
Hummers, W. S., & Offeman, R. E. (1958) · Journal of the American Chemical Society · doi:10.1021/ja01539a017 · Cited by 29,920
Biesinger, M. C., Payne, B. P., Grosvenor, A. P., Lau, L. W. M., Gerson, A. R., & Smart, R. S. C. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2010.10.051 · Cited by 11,640
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
Biesinger, M. C., Lau, L. W. M., Gerson, A. R., & Smart, R. S. C. (2010) · Applied Surface Science · doi:10.1016/j.apsusc.2010.07.086 · Cited by 4,592
Huang, X., Qi, X., Boey, F., & Zhang, H. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15078b · Cited by 3,837
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes
Wei, H., & Wang, E. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35486e · Cited by 3,779
Graphene Oxide: Intrinsic Peroxidase Catalytic Activity and Its Application to Glucose Detection
Song, Y., Qu, K., Zhao, C., Ren, J., & Qu, X. (2010) · Advanced Materials · doi:10.1002/adma.200903783 · Cited by 2,024
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene
Zhu, Z., Garcia-Gancedo, L., Flewitt, A. J., Xie, H., Moussy, F., & Milne, W. I. (2012) · Sensors · doi:10.3390/s120505996 · Cited by 549
Dong, Y.-L., Zhang, H.-G., Rahman, Z. U., Su, L., Chen, X.-J., Hu, J., & Chen, X.-G. (2012) · Nanoscale · doi:10.1039/c2nr12109c · Cited by 533
Cited by
A Review on Metal- and Metal Oxide-Based Nanozymes: Properties, Mechanisms, and Applications
Liu, Q., Zhang, A., Wang, R., Zhang, Q., & Cui, D. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00674-8 · Cited by 745
Carbon Nanozymes: Enzymatic Properties, Catalytic Mechanism, and Applications
Sun, H., Zhou, Y., Ren, J., & Qu, X. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201712469 · Cited by 648
Vázquez-González, M., Liao, W.-C., Cazelles, R., Wang, S., Yu, X., Gutkin, V., & Willner, I. (2017) · ACS Nano · doi:10.1021/acsnano.7b00352 · Cited by 323
Electrospun polymer micro/nanofibers as pharmaceutical repositories for healthcare
Feng, X., Li, J., Zhang, X., Liu, T., Ding, J., & Chen, X. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.03.020 · Cited by 322
Han, L., Zhang, H., Chen, D., & Li, F. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201800018 · Cited by 309
Metadata
- Authors
- Darabdhara, G., Sharma, B., Das, M. R., Boukherroub, R., & Szunerits, S.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 238
- Pages
- 842-851
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2475793179
- Cited by
- 340
- References
- 38
- FWCI
- 14.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cu-Ag bimetallic nanoparticles on reduced graphene oxide nanosheets as peroxidase mimic for glucose and ascorbic acid detection. https://app.cochat.ai/papers/10.1016/j.snb.2016.07.106
- The paper
- Darabdhara, G., Sharma, B., Das, M. R., Boukherroub, R., & Szunerits, S. (2017). Cu-Ag bimetallic nanoparticles on reduced graphene oxide nanosheets as peroxidase mimic for glucose and ascorbic acid detection. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2016.07.106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.