The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Room temperature toluene gas sensor based on TiO2 nanoparticles decorated 3D graphene-carbon nanotube nanostructures
Abstract
This work presents a highly sensitive room-temperature gas sensor based on 3D titanium dioxide/graphene-carbon nanotube (3D TiO2/G-CNT) fabricated by chemical vapor deposition and sparking methods. Characterizations by scanning electron microscopy, X-ray photoelectron spectroscopy, Raman spectroscopy and Transmission electron microscopy confirmed the formation of 3D graphene-carbon nanotube nanostructures decorated with TiO2 nanoparticles. The toluene detection performances of 3D TiO2/G-CNT structures with varying Ti sparking times were investigated in comparison with 3D G-CNT, TiO2-CNT, graphene and CNTs at room temperature. From result, the optimal sparking time of 60 s led to an optimal sensor response of 42%–500 ppm at room temperature. In addition, the optimal 3D TiO2/G-CNT exhibited substantially higher toluene response, sensitivity and selectivity than 3D G-CNT, TiO2-CNT, graphene and CNTs over a low concentration range of 50–500 ppm. The toluene-sensing mechanisms of 3D titanium dioxide/graphene-carbon nanotube nanostructures were proposed based on the formation of Schottky metal-semiconductor junctions between metallic 3D graphene-carbon nanotube structures and n-type semiconducting titanium dioxide nanoparticles due to the adsorption of toluene molecules via low-temperature reducing reactions or direct charge transfer process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Review on Graphene-Based Gas/Vapor Sensors with Unique Properties and Potential Applications
Wang, T., Huang, D., Yang, Z., Xu, S., He, G., Li, X., Hu, N., Yin, G., He, D., & Zhang, L. (2016) · Nano-Micro Letters · doi:10.1007/s40820-015-0073-1 · Cited by 600
Cited by
Nanomaterials-based biosensor and their applications: A review
Malik, S., Singh, J., Goyat, R., Saharan, Y., Chaudhry, V., Umar, A., Ibrahim, A. A., Akbar, S., Ameen, S., & Baskoutas, S. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e19929 · Cited by 441
Selectivity in Chemiresistive Gas Sensors: Strategies and Challenges
Bulemo, P. M., Kim, D.-H., Shin, H., Cho, H.-J., Koo, W.-T., Choi, S.-J., Park, C., Ahn, J., Güntner, A. T., Penner, R. M., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00592 · Cited by 418
Recent Progress on Flexible Room-Temperature Gas Sensors Based on Metal Oxide Semiconductor
Ou, L.-X., Liu, M.-Y., Zhu, L.-Y., Zhang, D. W., & Lu, H.-L. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00956-9 · Cited by 402
Ding, Q., Zhou, Z., Wang, H., Wu, Z., Tao, K., Yang, B., Xie, X., Fu, J., & Wu, J. (2023) · SmartMat · doi:10.1002/smm2.1141 · Cited by 72
Metadata
- Authors
- Seekaew, Y., Wisitsoraat, A., Phokharatkul, D., & Wongchoosuk, C.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 279
- Pages
- 69-78
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2894595208
- Cited by
- 210
- References
- 1
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Room temperature toluene gas sensor based on TiO2 nanoparticles decorated 3D graphene-carbon nanotube nanostructures. https://app.cochat.ai/papers/10.1016/j.snb.2018.09.095
- The paper
- Seekaew, Y., Wisitsoraat, A., Phokharatkul, D., & Wongchoosuk, C. (2019). Room temperature toluene gas sensor based on TiO2 nanoparticles decorated 3D graphene-carbon nanotube nanostructures. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.09.095
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.