Cited by 72Gas Sensing Nanomaterials and SensorsAdvanced Sensor and Energy Harvesting MaterialsConducting polymers and applications

Self‐healable, recyclable, ultrastretchable, and high‐performance NO 2 sensors based on an organohydrogel for room and sub‐zero temperature and wireless operation

Open access
Ding, Qiongling, Zhou, Zijing, Wang, Hao, Wu, Zixuan, Tao, Kai, Yang, Bo‐Ru, Xie, Xi, Fu, Jun +1 more·2023·SmartMat

Abstract

To date, development of high‐performance, stretchable gas sensors operating at and below room temperature (RT) remains a challenge in terms of traditional sensing materials. Herein, we report on a high‐performance NO 2 gas sensor based on a self‐healable, recyclable, ultrastretchable, and stable polyvinyl alcohol–cellulose nanofibril double‐network organohydrogel, which features ultrahigh sensitivity (372%/ppm), low limit of detection (2.23 ppb), relatively fast response and recovery time (41/144 s for 250 ppb NO 2 ), good selectivity against interfering gases (NH 3 , CO 2 , ethanol, and acetone), excellent reversibility, repeatability, and long‐term stability at RT or even at −20°C. In particular, this sensor shows outstanding stability against large deformations and mechanical damages so that it works normally after rapid self‐healing or remolding after undergoing mechanical damage without significant performance degradation, which has major advantages compared to state‐of‐the‐art gas sensors. The high NO 2 sensitivity and selectivity are attributed to the selective redox reactions at the three‐phase interface of gas, gel, and electrode, which is even boosted by applying tensile strain. With a specific electrical circuit design, a wireless NO 2 alarm system based on this sensor is created to enable continuous, real‐time, and wireless NO 2 detection to avoid the risk of exposure to NO 2 higher than threshold concentrations.

Integrity signals

Registry

Crossref · 10.1002/smm2.1141

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications such as NO2, NH3, CO2, and O2.

    “Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications, such as NO2, NH3, CO2, and O2”
  • PVA/CNF-glycerol DN organohydrogel has significantly improved water storage and freezing resistance, and could carry out normally after placed at −20°C for a long time.

    “Ding et al. [67] used a facile one-pot polymerization method to prepare PVA/cellulose nanofibril (CNF)–glycerol (Gly) DN organohydrogel with significantly improved water storage and freezing resistance (Fig. 4c), which could carry out normally after placed at − 20 °C for a long time”
  • Ding et al. [67] developed a NO2 hydrogel sensor capable of operating at room temperature or even at −20 °C using a PVA-CNF DN organohydrogel with a water/Gly binary solvent.

    “Ding et al. [67] developed a NO2 hydrogel sensor capable of operating at room temperature or even at − 20 °C, as illustrated in Fig. 8e. They used a PVA–CNF DN organohydrogel with a water/Gly binary solvent to realize high-efficiency sensing of NO2.”
  • After being cut or remolded, the sensor can still heal, recover and retain its original conductive and sensitive properties perfectly.

    “After being cut or remolded, it can still heal, recover and retain its original conductive and sensitive properties perfectly, which implies better endurance and more application possibilities”
  • The sensor has ultrahigh sensitivity (372% ppm−1), low LOD (2.23 ppb), fast response and recovery time (41/144 s for 250 ppb NO2), and high selectivity to NO2.

    “The sensor has ultrahigh sensitivity (372% ppm−1), low LOD (2.23 ppb), fast response and recovery time (41/144 s for 250 ppb NO2), and high selectivity to NO2.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ding, Q., Zhou, Z., Wang, H., Wu, Z., Tao, K., Yang, B., Xie, X., Fu, J., & Wu, J.
Affiliations
  • Sun Yat-sen University (CN)
  • Northwestern Polytechnical University (CN)
Corresponding author
Wu, Jin
Venue
SmartMat
Publisher
Wiley
Published
2022-07-29
Volume
4
Issue
1
ISSN
2688-819X (ISSN-L)
OpenAlex
W4288514189
Cited by
72
References
5
Citations by year
2026: 10 · 2025: 13 · 2024: 18 · 2023: 26 · 2022: 5
FWCI
4.25
Type
journal article
Language
en
Open access
Locations
  • SmartMat (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Natural Science Foundation of China (61801525)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
NO2 gas sensor, organohydrogel, double-network hydrogel, polyvinyl alcohol, cellulose nanofibers, self-healing materials, recyclable sensors, redox sensing, three-phase interface, gas selectivity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review