Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

MoSe2 nanoflakes based chemiresistive sensors for ppb-level hydrogen sulfide gas detection

Jha, Ravindra Kumar, D’Costa, Jostin Vinroy, Sakhuja, Neha, Bhat, Navakanta · 2019 · Sensors and Actuators B: Chemical

Abstract

Abstract Detection and quantification of hydrogen sulfide (H2S) gas is important as it influences directly human health, our environment, and operations of several industries including food and beverages, oil, construction, and medicine. It also acts as biomarker in diagnosis of halitosis at early stage. We report herein liquid exfoliated MoSe2 nanoflakes based stable chemiresistive H2S gas sensor which operate at moderate temperature of 200℃. The response of p-type MoSe2 gas sensor device (when operated in ambient environment) was found to be varying between 15.87%–53.04% when the concentration of H2S was varied between 50 ppb – 5.45 ppm. The response of the device decreases when the measurements were done in synthetic air environment and it varies between 7.13%–19.87% for the concentration range of 500 ppb - 5.45 ppm. The response (%), recovery rate (%), hysteresis, experimental lowest detection limit etc. of the device suggest that the device performs better when operated in ambient than in synthetic air which suggest its real time device application. The response time and recovery time of the sensor are 15 s and 43 s respectively for 100 ppb of H2S. The sensor performance was found to be highly repeatable with sensitivity of 5.57%/ppm of H2S. The theoretical limit of detection and limit of quantization of the device were found to be 6.73 ppb and 22.44 ppb respectively. Based on chemical analysis, a plausible mechanism based on charge transfer phenomenon has been proposed for this sensor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2019.126687

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 171

Metadata

Authors
Jha, R. K., D’Costa, J. V., Sakhuja, N., & Bhat, N.
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2019-10
Volume
297
Pages
126687
ISSN
0925-4005 (ISSN-L)
OpenAlex
W2951941064
Cited by
171
References
3
FWCI
7.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MoSe2 nanoflakes based chemiresistive sensors for ppb-level hydrogen sulfide gas detection. https://app.cochat.ai/papers/10.1016/j.snb.2019.126687
The paper
Jha, R. K., D’Costa, J. V., Sakhuja, N., & Bhat, N. (2019). MoSe2 nanoflakes based chemiresistive sensors for ppb-level hydrogen sulfide gas detection. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2019.126687

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.