The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Toward agricultural ammonia volatilization monitoring: A flexible polyaniline/Ti3C2T hybrid sensitive films based gas sensor
Abstract
The monitoring of ammonia (NH3) produced in agricultural fields is of great importance due to its huge threat to ecological environment and human health, yet routine monitoring technologies rely on manual completion and complex agricultural environment brings great challenges to the application feasibility of gas sensors. Herein, a flexible chemiresistive gas sensor based on polyaniline (PANI)/Ti3C2Tx hybrid sensitive films is developed toward agricultural NH3 volatilization monitoring. The hybrid film was deposited on the flexible polyimide substrate by an in-situ self-assembly method. The sensor shows high sensitivity, low detection limit, excellent repeatability, high selectivity and good air stability, which could be attributed to the gas-sensing enhancement effects of PANI/Ti3C2Tx Schottky junction and improved protonation degree of PANI in the hybrids. Especially, the sensor exhibits excellent NH3-sensing properties to 20–80 % relative humidity (RH) environments at a temperature range of 10–40 ℃, making it promising for practical agricultural applications. Furthermore, the application feasibility of the sensor to ammonia volatilization monitoring is verified through agricultural simulation experiments. This work provides a fast and accurate gas sensor methodology toward unattended agricultural application, which is an important supplement to the existing technical methods and may greatly pushes forward the development of modernized intelligent agriculture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Room Temperature Gas Sensing of Two-Dimensional Titanium Carbide (MXene)
Lee, E., VahidMohammadi, A., Prorok, B. C., Yoon, Y. S., Beidaghi, M., & Kim, D.-J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b11055 · Cited by 878
Cited by
Chaudhary, V., Kaushik, A., Furukawa, H., & Khosla, A. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac5ac6 · Cited by 386
Age of Flexible Electronics: Emerging Trends in Soft Multifunctional Sensors
Lee, J., Cho, K., & Kim, J. (2024) · Advanced Materials · doi:10.1002/adma.202310505 · Cited by 355
2D metal carbides and nitrides (MXenes) for sensors and biosensors
Alwarappan, S., Nesakumar, N., Sun, D., Hu, T. Y., & Li, C.-Z. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113943 · Cited by 262
Metadata
- Authors
- Li, X., Xu, J., Jiang, Y., He, Z., Liu, B., Xie, H., Li, H., Li, Z., Wang, Y., & Tai, H.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 316
- Pages
- 128144
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W3018779211
- Cited by
- 243
- References
- 2
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.