Cited by 69Gas Sensing Nanomaterials and SensorsConducting polymers and applicationsAnalytical Chemistry and Sensors

Room temperature ammonia gas sensor based on ionic conductive biomass hydrogels

Liu, Lichao, Fei, Teng, Guan, Xin, Lin, Xiuzhu, Zhao, Hongran, Zhang, Tong·2020·Sensors and Actuators B: Chemical

Integrity signals

Registry

Crossref · 10.1016/j.snb.2020.128318

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications such as NO2, NH3, CO2, and O2.

    “Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications, such as NO2, NH3, CO2, and O2”
  • Liu et al. [71] prepared a highly sensitive, non-toxic, and environmentally friendly electrical NH3 hydrogel sensor under humid environment at 25 °C using biomass hydrogel GA and PGA as sensitive composite materials.

    “Similarly, Liu et al. [71] prepared a highly sensitive, non-toxic, and environmentally friendly electrical NH3 hydrogel sensor under humid environment at 25 °C using biomass hydrogel GA and poly-L-glutamate (PGA) as sensitive composite materials.”
  • The sensor showed a response of up to 8.4 to 50 ppm NH3 at 80% RH with a LOD as low as 0.5 ppm, and good NH3 selectivity.

    “The sensor showed a response of up to 8.4 to 50 ppm NH3 at 80% RH with a LOD as low as 0.5 ppm, and good NH3 selectivity.”
  • At high humidity, the sensitive material adsorbs more water to form a condensed water layer, and proton conductivity makes H2O and NH3 start to move.

    “At high humidity, the sensitive material adsorbs more water to form a condensed water layer, and the proton conductivity makes H2O and NH3 start to move.”
  • PGA and GA have good chemical compatibility because of their similar chemical structures.

    “As shown in Fig. 9c-d, firstly, PGA and GA have good chemical compatibility because of their similar chemical structures.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Liu, L., Fei, T., Guan, X., Lin, X., Zhao, H., & Zhang, T.
Affiliations
Jilin University (CN)
Corresponding author
  • Fei, Teng
  • Zhao, Hongran
  • Zhang, Tong
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2020-10
Volume
320
Pages
128318
ISSN
0925-4005 (ISSN-L)
OpenAlex
W3027028032
Cited by
69
References
2
Citations by year
2026: 8 · 2025: 8 · 2024: 15 · 2023: 11 · 2022: 15 · 2021: 10 · 2020: 2
FWCI
3.26
Type
journal article
Language
en
Open access
closed
Locations
Sensors and Actuators B Chemical (publishedVersion)
Funders
  • Natural Science Foundation Committee (61903150, 61773178)
  • China Postdoctoral Science Foundation (801191010412)
  • Projects of Science and Technology Development Plan of Jilin Province (20200801037GH)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
ammonia gas sensor, room-temperature gas sensing, ionic conductive hydrogel, poly(L-glutamic acid), glutamate, breath analysis, humidity tolerance, kidney disease diagnosis, quartz crystal microbalance, impedance spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review