They monitored oxygen in monolayer cultures with T-47D breast cancer cells, demonstrating the applicability of the sensor in cell culture oxygen concentration detection.
“They also monitored oxygen in monolayer cultures with T-47D breast cancer cells, which further demonstrates the applicability of the sensor in cell culture oxygen concentration detection.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as [233]
Liebisch et al. [233] prepared Clark-type oxygen microsensors that can operate in an aqueous environment using a PHEMA hydrogel layer containing a buffer solution as the electrolyte, platinum as the electrode material, and PDMS as the gas permeable membrane.
“Liebisch et al. [233] prepared a Clark-type oxygen microsensors that can operate in an aqueous environment. They used a PHEMA hydrogel layer containing a buffer solution as the electrolyte, platinum as the electrode material for the sensor, and polydimethylsiloxane (PDMS) as the gas permeable membrane.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as [233]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 28
- Ebbesen, 2009, Taking advantage of tumor cell adaptations to hypoxia for developing new tumor markers and treatment strategies, J. Enzyme Inhib. Med. Chem., 24, 1, 10.1080/14756360902784425 · DOI
- Pettersen, 2015, Targeting tumour hypoxia to prevent cancer metastasis. From biology, biosensing and technology to drug development: the METOXIA consortium, J. Enzyme Inhib. Med. Chem., 30, 689, 10.3109/14756366.2014.966704 · DOI
- Lavrentieva, 2010, Effects of hypoxic culture conditions on umbilical cord-derived human mesenchymal stem cells, Cell Commun. Signal, 8, 18, 10.1186/1478-811X-8-18 · DOI · Paper page
- Kieninger, 2018, Microsensor systems for cell metabolism – from 2D culture to organ-on-chip, Lab Chip, 18, 1274, 10.1039/C7LC00942A · DOI
- Pettersen, 2005, Pericellular oxygen depletion during ordinary tissue culturing, measured with oxygen microsensors, Cell Prolif., 38, 257, 10.1111/j.1365-2184.2005.00345.x · DOI
- Weltin, 2014, Cell culture monitoring for drug screening and cancer research: a transparent, microfluidic, multi-sensor microsystem, Lab Chip, 14, 138, 10.1039/C3LC50759A · DOI
- Kieninger, 2014, Pericellular oxygen monitoring with integrated sensor chips for reproducible cell culture experiments, Cell Prolif., 47, 180, 10.1111/j.1365-2184.2013.12089.x · DOI
- Weltin, 2017, Accessing 3D microtissue metabolism: lactate and oxygen monitoring in hepatocyte spheroids, Biosens. Bioelectron., 87, 941, 10.1016/j.bios.2016.07.094 · DOI
- Kieninger, 2018, Sensor access to the cellular microenvironment using the sensing cell culture flask, Biosensors, 8, 44, 10.3390/bios8020044 · DOI
- Marzioch, 2018, On-chip photodynamic therapy – monitoring cell metabolism using electrochemical microsensors, Lab Chip, 18, 3353, 10.1039/C8LC00799C · DOI
- Guarino, 2004, Method for determining oxygen consumption rates of static cultures from microplate measurements of pericellular dissolved oxygen concentration, Biotechnol. Bioeng., 86, 775, 10.1002/bit.20072 · DOI
- Beckers, 2010, High throughput, non-invasive and dynamic toxicity screening on adherent cells using respiratory measurements, Toxicol. In Vitro, 24, 686, 10.1016/j.tiv.2009.04.018 · DOI
- Clark Jr, 1956, Monitor and control of blood and tissue oxygen tensions, Trans. Am. Soc. Artif. Intern. Organs, 2, 41
- Koudelka, 1986, Performance characteristics of a planar ‘clark-type’ oxygen sensor, Sens. Actuators, 9, 249, 10.1016/0250-6874(86)80025-7 · DOI
- Suzuki, 1990, Miniature Clark-type oxygen electrode with a three-electrode configuration, Sens. Actuators B. Chem., 2, 297, 10.1016/0925-4005(90)80157-U · DOI
- Suzuki, 1993, Micromachined Clark oxygen electrode, Sens. Actuators B. Chem., 10, 91, 10.1016/0925-4005(93)80031-6 · DOI
- Jobst, 1993, Thin-film Clark-type oxygen sensor based on novel polymer membrane systems for in vivo and biosensor applications, Biosens. Bioelectron., 8, 123, 10.1016/0956-5663(93)85024-I · DOI
- Suzuki, 1994, Disposable clark oxygen electrode using recycled materials and its application, Sens. Actuators B Chem., 21, 17, 10.1016/0925-4005(93)01207-K · DOI
- Yang, 1997, Fabrication of oxygen electrode arrays and their incorporation into sensors for measuring biochemical oxygen demand, Anal. Chim. Acta, 357, 41, 10.1016/S0003-2670(97)00560-6 · DOI
- Suzuki, 1998, A novel thin-film Ag/AgCl anode structure for microfabricated Clark-type oxygen electrodes, Sens. Actuators B Chem., 53, 140, 10.1016/S0925-4005(99)00009-X · DOI
- McLaughlin, 2002, Microfabricated solid-state dissolved oxygen sensor, Sens. Actuators B Chem., 83, 138, 10.1016/S0925-4005(02)00021-7 · DOI
- Wu, 2005, Fabrication of miniature Clark oxygen sensor integrated with microstructure, Sens. Actuators B Chem., 110, 342, 10.1016/j.snb.2005.02.014 · DOI
- Wu, 2010, A Clark-type oxygen chip for in situ estimation of the respiratory activity of adhering cells, Talanta, 81, 228, 10.1016/j.talanta.2009.11.062 · DOI
- Park, 2010, A microfabricated reservoir-type oxygen sensor for measuring the real-time cellular oxygen consumption rate at various conditions, Sensors Actuators B Chem., 147, 263, 10.1016/j.snb.2010.03.069 · DOI
- Park, 2013, A reservoir-type oxygen sensor with 2×3 array for measuring cellular respiration levels, Sensors Actuators, B Chem., 176, 913, 10.1016/j.snb.2012.09.037 · DOI
- Weisenberger, 1996, Estimation of gas solubilities in salt solutions at temperatures from 273 K to 363 K, AIChE J., 42, 298, 10.1002/aic.690420130 · DOI
- Keydar, 1979, Establishment and characterization of a cell line of human breast carcinoma origin, Eur. J. Cancer, 15, 659, 10.1016/0014-2964(79)90139-7 · DOI
- Daubinger, 2014, Electrochemical characteristics of nanostructured platinum electrodes – a cyclic voltammetry study, Phys. Chem. Chem. Phys., 16, 8392, 10.1039/C4CP00342J · DOI
Cited by
Sorted by citations
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236
“Liebisch et al. [233] prepared a Clark-type oxygen micro-sensors that can operate in an aqueous environment.”
Background
Metadata
- Authors
- Liebisch, F., Weltin, A., Marzioch, J., Urban, G. A., & Kieninger, J.
- Affiliations
- University of Freiburg (DE)
- Corresponding author
- Kieninger, Jochen
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2020-11
- Volume
- 322
- Pages
- 128652
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W3044607496
- Cited by
- 53
- References
- 0
- Citations by year
- 2026: 6 · 2025: 5 · 2024: 10 · 2023: 12 · 2022: 11 · 2021: 9
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Sensors and Actuators B Chemical (publishedVersion)
- Funders
- European Commission
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- feedback mode, platinum electrode, chronoamperometry, long-term sensor stability, one-point calibration, T47D cells, organ-on-a-chip
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review