The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Flexible humidity sensor based on modified cellulose paper
Abstract
It is of great significance to exploit a simple, cost-effective and environmentally friendly preparation method of multifunctional humidity sensors. However, most humidity sensors need complex manufacturing processes, high cost and narrow usage range. Herein, humidity sensors based on glycidyl trimethyl ammonium chloride (EPTAC) modified cellulose paper via a facile solution method were fabricated, among which the paper is used for the purpose of the humidity sensing material and the sensor substrate. The sensitivity of the obtained sensor was improved by the modification of EPTAC, the response time was decreased to 25 s, which is equivalent to the first-rate paper-based humidity sensors. In addition, the paper-based humidity sensor is provided with well flexibility and biocompatibility, and it exhibits multifunctional applications in respiratory monitoring, non-contact switch and skin humidity monitoring. The low cost and facile preparation technique in this work could provide a useful strategy for developing multifunctional humidity sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Paper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472
Porous Ionic Membrane Based Flexible Humidity Sensor and its Multifunctional Applications
Li, T., Li, L., Sun, H., Xu, Y., Wang, X., Luo, H., Liu, Z., & Zhang, T. (2017) · Advanced Science · doi:10.1002/advs.201600404 · Cited by 298
Self-citationZhou, G., Byun, J.-H., Oh, Y., Jung, B.-M., Cha, H.-J., Seong, D.-G., Um, M.-K., Hyun, S., & Chou, T.-W. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b12448 · Cited by 264
Cited by
Recent advances in humidity sensors for human body related humidity detection
Duan, Z., Jiang, Y., & Tai, H. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc04180k · Cited by 365
Multifunctional Flexible Humidity Sensor Systems Towards Noncontact Wearable Electronics
Lu, Y., Yang, G., Shen, Y., Yang, H., & Xu, K. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00895-5 · Cited by 320
Metadata
- Authors
- Guan, X., Hou, Z., Wu, K., Zhao, H., Liu, S., Fei, T., & Zhang, T.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 339
- Pages
- 129879
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W3149144618
- Cited by
- 174
- References
- 4
- FWCI
- 8.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible humidity sensor based on modified cellulose paper. https://app.cochat.ai/papers/10.1016/j.snb.2021.129879
- The paper
- Guan, X., Hou, Z., Wu, K., Zhao, H., Liu, S., Fei, T., & Zhang, T. (2021). Flexible humidity sensor based on modified cellulose paper. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2021.129879
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.