The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fault detection and diagnosis based on C4.5 decision tree algorithm for grid connected PV system
Abstract
In this paper, a new approach based on decision tree algorithm to detect and diagnose the faults in grid connected photovoltaic system (GCPVS) is proposed. A non-parametric model to predict the state of GCPVS by learning task is used; a data set is collected from GCPVS by the acquisition system under several weather conditions. Three numerical attributes and two targets are chosen to form the final used data, the attributes are temperature ambient, irradiation and power ratio calculated from measured and estimated power, the first target is either healthy or faulty state for detection; the second one contains four classes’ labels named free fault, string fault, short circuit fault or line-line fault for diagnosis. The Sandia model is applied to estimate the power generated from GCPVS operating in healthy state. The data set has been divided into two parts, where 66% was used for the learning and the remained for testing. Subsequently, a new data was recorded from five days in order to evaluate robustness, effectiveness and efficiency of both models. Testing result indicate that the models have a high prediction performance in the detection with high accuracy while the diagnosis model have accuracy equal to 99.80%. Moreover, the models have been evaluated in five days; the added data guarantees the prediction efficiency resulting in high accuracy for the detection and the diagnosis, whereas the classification is correct for 99%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quinlan, J. R. (1986) · Machine Learning · doi:10.1007/bf00116251 · Cited by 21,439
Cited by
Chen, Z., Chen, Y., Wu, L., Cheng, S., & Lin, P. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.111793 · Cited by 347
Chen, Z., Han, F., Wu, L., Yu, J., Cheng, S., Lin, P., & Chen, H. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.10.040 · Cited by 320
Application of Artificial Neural Networks to photovoltaic fault detection and diagnosis: A review
Li, B., Delpha, C., Diallo, D., & Migan-Dubois, A. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110512 · Cited by 306
Mellit, A., & Kalogirou, S. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.110889 · Cited by 280
Tran, M.-Q., Elsisi, M., Mahmoud, K., Liu, M.-K., Lehtonen, M., & Darwish, M. M. F. (2021) · IEEE Access · doi:10.1109/access.2021.3105297 · Cited by 158
Metadata
- Authors
- Benkercha, R., & Moulahoum, S.
- Venue
- Solar Energy
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 173
- Pages
- 610-634
- ISSN
- 0038-092X (ISSN-L)
- OpenAlex
- W2886946090
- Cited by
- 193
- References
- 1
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault detection and diagnosis based on C4.5 decision tree algorithm for grid connected PV system. https://app.cochat.ai/papers/10.1016/j.solener.2018.07.089
- The paper
- Benkercha, R., & Moulahoum, S. (2018). Fault detection and diagnosis based on C4.5 decision tree algorithm for grid connected PV system. Solar Energy. https://doi.org/10.1016/j.solener.2018.07.089
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.