The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model
Open accessAbstract
BACKGROUND CONTEXT: There is significant variability in the materials commonly used for interbody cages in spine surgery. It is theorized that three-dimensional (3D)-printed interbody cages using porous titanium material can provide more consistent bone ingrowth and biological fixation. PURPOSE: The purpose of this study was to provide an evidence-based approach to decision-making regarding interbody materials for spinal fusion. STUDY DESIGN: A comparative animal study was performed. METHODS: A skeletally mature ovine lumbar fusion model was used for this study. Interbody fusions were performed at L2-L3 and L4-L5 in 27 mature sheep using three different interbody cages (ie, polyetheretherketone [PEEK], plasma sprayed porous titanium-coated PEEK [PSP], and 3D-printed porous titanium alloy cage [PTA]). Non-destructive kinematic testing was performed in the three primary directions of motion. The specimens were then analyzed using micro-computed tomography (µ-CT); quantitative measures of the bony fusion were performed. Histomorphometric analyses were also performed in the sagittal plane through the interbody device. Outcome parameters were compared between cage designs and time points. RESULTS: Flexion-extension range of motion (ROM) was statistically reduced for the PTA group compared with the PEEK cages at 16 weeks (p-value=.02). Only the PTA cages demonstrated a statistically significant decrease in ROM and increase in stiffness across all three loading directions between the 8-week and 16-week sacrifice time points (p-value≤.01). Micro-CT data demonstrated significantly greater total bone volume within the graft window for the PTA cages at both 8 weeks and 16 weeks compared with the PEEK cages (p-value<.01). CONCLUSIONS: A direct comparison of interbody implants demonstrates significant and measurable differences in biomechanical, µ-CT, and histologic performance in an ovine model. The 3D-printed porous titanium interbody cage resulted in statistically significant reductions in ROM, increases in the bone ingrowth profile, as well as average construct stiffness compared with PEEK and PSP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Animal Physiology: Adaptation and Environment
Schmidt‐Nielsen, K. (1962) · Cited by 2,489
Animal models for implant biomaterial research in bone: A review
AO Research Institute, A. F., Pearce, A., Richards, R., Milz, S., Schneider, E., & Pearce, S. (2007) · European Cells and Materials · doi:10.22203/ecm.v013a01 · Cited by 1,289
Animal Physiology: Adaptation and environment
Baggott, G. K. (1985) · Journal of Arid Environments · doi:10.1016/s0140-1963(18)31286-2 · Cited by 1,098
Are Sheep Spines a Valid Biomechanical Model for Human Spines?
Wilke, H.-J., Kettler, A., & Claes, L. E. (1997) · Spine · doi:10.1097/00007632-199710150-00009 · Cited by 455
Anatomy of the sheep spine and its comparison to the human spine
Wilke, H.-J., Kettler, A., Wenger, K. H., & Claes, L. E. (1997) · The Anatomical Record · doi:10.1002/(sici)1097-0185(199704)247:4<542::aid-ar13>3.0.co;2-p · Cited by 369
Arthrodesis by the Distraction-Compression Method Using a Stainless Steel Implant
Bagby, G. W. (1988) · Orthopedics · doi:10.3928/0147-7447-19880601-13 · Cited by 369
Seaman, S., Kerezoudis, P., Bydon, M., Torner, J. C., & Hitchon, P. W. (2017) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2017.06.062 · Cited by 294
Rao, P. J., Pelletier, M. H., Walsh, W. R., & Mobbs, R. J. (2014) · Orthopaedic Surgery · doi:10.1111/os.12098 · Cited by 285
Anatomy of large animal spines and its comparison to the human spine: a systematic review
Sheng, S., Wang, X., Xu, H., Zhu, G., & Zhou, Y. (2009) · European Spine Journal · doi:10.1007/s00586-009-1192-5 · Cited by 231
Yu, S., Hariram, K. P., Kumar, R., Cheang, P., & Aik, K. K. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.028 · Cited by 228
Cited by
Wang, W., Zhang, B., Li, M., Li, J., Zhang, C., Han, Y., Wang, L., Wang, K., Zhou, C., Liu, L., et al. (2021) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2021.109192 · Cited by 369
Top Three Healthcare Trends in Orthopaedics Affecting Musculoskeletal Care in the Elderly
Lorio, M. P., Lewandrowski, K.-U., & Blum, K. (2025) · Current Aging Science · doi:10.2174/0118746098309054240721180720 · Cited by 2
Metadata
- Authors
- McGilvray, K. C., Easley, J., Seim, H. B., Regan, D., Berven, S. H., Hsu, W. K., Mroz, T. E., & Puttlitz, C. M.
- Venue
- The Spine Journal
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 18
- Issue
- 7
- Pages
- 1250-1260
- ISSN
- 1529-9430 (ISSN-L)
- OpenAlex
- W2792113610
- Cited by
- 256
- References
- 23
- FWCI
- 13.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model. https://app.cochat.ai/papers/10.1016/j.spinee.2018.02.018
- The paper
- McGilvray, K. C., Easley, J., Seim, H. B., Regan, D., Berven, S. H., Hsu, W. K., Mroz, T. E., & Puttlitz, C. M. (2018). Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model. The Spine Journal. https://doi.org/10.1016/j.spinee.2018.02.018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.