CoChat

Detection and quantitation of ecdysterone in human serum by liquid chromatography coupled to tandem mass spectrometry

Ambrosio, Gabriella, Joseph, Jan Felix, Wuest, Bernhard, Mazzarino, Monica, de la Torre, Xavier, Diel, Patrick, Botrè, Francesco, Parr, Maria Kristina · 2020 · Steroids
Cited by 14

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

The polyhydroxylated phytosteroid ecdysterone is present in various plants (e.g. spinach). It is widely marketed as the active component of dietary supplements, due to its reported health and performance promoting effects. For evaluation of its actual bioavailability, a fast and sensitive method was developed, optimized and validated for human serum. Instrumental analysis was performed utilizing liquid chromatography-tandem mass spectrometry with positive electrospray ionization and acquisition in multiple reaction mode. Solid phase extraction and dilute-and-inject (following protein precipitation) were tested to isolate ecdysterone from human serum. Both methods were compared in the light of the preset analytical target profile. The limit of detection (LOD) and quantification (LOQ) for ecdysterone in human serum after SPE extraction corresponded to 0.06 ng/mL and 0.14 ng/mL, respectively, meeting the requested sensitivity of the method. The assay was linear over the range from 0.10 ng/mL to 20.83 ng/mL. As expected, the sensitivity of the SPE method was better than that of the dilute-and-inject procedure, which did not allow for quantification of all post administration serum samples. Accuracy (relative error; %) and precision (coefficient of variation; %), were both within acceptance criteria (<15%). The developed method was successfully applied to a ten week intervention study conducted in young men performing regular resistance training. Different doses of supplements containing ecdysterone from spinach extract have been administered during the study and the quantitation of ecdysterone in serum samples has been successfully conducted. Ecdysterone could be quantified in all post-administration samples using solid phase extraction (SPE) for sample pretreatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.steroids.2020.108603

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 14

Metadata

Authors
Ambrosio, G., Joseph, J. F., Wuest, B., Mazzarino, M., de la Torre, X., Diel, P., Botrè, F., & Parr, M. K.
Venue
Steroids
Publisher
Elsevier BV
Published
2020-05
Volume
157
Pages
108603
ISSN
0039-128X (ISSN-L)
OpenAlex
W3005606118
Cited by
14
References
13
FWCI
0.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection and quantitation of ecdysterone in human serum by liquid chromatography coupled to tandem mass spectrometry. https://app.cochat.ai/papers/10.1016/j.steroids.2020.108603
The paper
Ambrosio, G., Joseph, J. F., Wuest, B., Mazzarino, M., de la Torre, X., Diel, P., Botrè, F., & Parr, M. K. (2020). Detection and quantitation of ecdysterone in human serum by liquid chromatography coupled to tandem mass spectrometry. Steroids. https://doi.org/10.1016/j.steroids.2020.108603

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.