How Does a Voltage Sensor Interact with a Lipid Bilayer? Simulations of a Potassium Channel Domain
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The nature of voltage sensing by voltage-activated ion channels is a key problem in membrane protein structural biology. The way in which the voltage-sensor (VS) domain interacts with its membrane environment remains unclear. In particular, the known structures of Kv channels do not readily explain how a positively charged S4 helix is able to stably span a lipid bilayer. Extended (2 x 50 ns) molecular dynamics simulations of the high-resolution structure of the isolated VS domain from the archaebacterial potassium channel KvAP, embedded in zwitterionic and in anionic lipid bilayers, have been used to explore VS/lipid interactions at atomic resolution. The simulations reveal penetration of water into the center of the VS and bilayer. Furthermore, there is significant local deformation of the lipid bilayer by interactions between lipid phosphate groups and arginine side chains of S4. As a consequence of this, the electrostatic field is "focused" across the center of the bilayer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phospholipids and the origin of cationic gating charges in voltage sensors
Schmidt, D., Jiang, Q.-X., & MacKinnon, R. (2006) · Nature · doi:10.1038/nature05416 · Cited by 417
Computational studies of membrane channels
Roux, B., & Schulten, K. (2004) · Structure · doi:10.1016/j.str.2004.06.013 · Cited by 145 · cited 1×
“Molecular dynamics (MD) simulations provide a computational approach to exploring structure/function relationships of ion channels and related membrane proteins (Roux and Schulten, 2004) and the interactions of membrane proteins with their lipid bilayer environment (Deol et al., 2006).”
Background
Cited by
Herce, H. D., & Garcia, A. E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706574105 · Cited by 471
Lipids on the move: Simulations of membrane pores, domains, stalks and curves
Marrink, S. J., de Vries, A. H., & Tieleman, D. P. (2009) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2008.10.006 · Cited by 440
Membrane proteins: molecular dynamics simulations
LINDAHL, E., & SANSOM, M. (2008) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2008.02.003 · Cited by 314
Self-citationSensing voltage across lipid membranes
Swartz, K. J. (2008) · Nature · doi:10.1038/nature07620 · Cited by 293
Muller, M. P., Jiang, T., Sun, C., Lihan, M., Pant, S., Mahinthichaichan, P., Trifan, A., & Tajkhorshid, E. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00608 · Cited by 282
Metadata
- Authors
- Sands, Z. A., & Sansom, M. S. P.
- Venue
- Structure
- Publisher
- Elsevier BV
- Published
- 2007-02
- Volume
- 15
- Issue
- 2
- Pages
- 235-244
- ISSN
- 0969-2126 (ISSN-L)
- OpenAlex
- W2145146108
- Cited by
- 93
- References
- 2
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.