The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Advances in Single-Particle Electron Cryomicroscopy Structure Determination applied to Sub-tomogram Averaging
Open accessAbstract
Recent innovations in specimen preparation, data collection, and image processing have led to improved structure determination using single-particle electron cryomicroscopy (cryo-EM). Here we explore some of these advances to improve structures determined using electron cryotomography (cryo-ET) and sub-tomogram averaging. We implement a new three-dimensional model for the contrast transfer function, and use this in a regularized likelihood optimization algorithm as implemented in the RELION program. Using direct electron detector data, we apply both single-particle analysis and sub-tomogram averaging to analyze radiation-induced movements of the specimen. As in single-particle cryo-EM, we find that significant sample movements occur during tomographic data acquisition, and that these movements are substantially reduced through the use of ultrastable gold substrates. We obtain a sub-nanometer resolution structure of the hepatitis B capsid, and show that reducing radiation-induced specimen movement may be central to attempts at further improving tomogram quality and resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446
Self-citationRosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416
Structure and assembly of immature HIV
Briggs, J. A. G., Riches, J. D., Glass, B., Bartonova, V., Zanetti, G., & Kräusslich, H.-G. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903535106 · Cited by 368
Structure of the immature HIV-1 capsid in intact virus particles at 8.8 Å resolution
Schur, F. K. M., Hagen, W. J. H., Rumlová, M., Ruml, T., Müller, B., Kräusslich, H.-G., & Briggs, J. A. G. (2015) · Nature · doi:10.1038/nature13838 · Cited by 296
Structure of the immature retroviral capsid at 8 Å resolution by cryo-electron microscopy
Bharat, T. A. M., Davey, N. E., Ulbrich, P., Riches, J. D., de Marco, A., Rumlova, M., Sachse, C., Ruml, T., & Briggs, J. A. G. (2012) · Nature · doi:10.1038/nature11169 · Cited by 171
Self-citationBharat, T. A. M., Castillo Menendez, L. R., Hagen, W. J. H., Lux, V., Igonet, S., Schorb, M., Schur, F. K. M., Kräusslich, H.-G., & Briggs, J. A. G. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1401455111 · Cited by 107
Self-citationTocheva, E. I., Matson, E. G., Morris, D. M., Moussavi, F., Leadbetter, J. R., & Jensen, G. J. (2011) · Cell · doi:10.1016/j.cell.2011.07.029 · Cited by 103
Cited by
New tools for automated high-resolution cryo-EM structure determination in RELION-3
Zivanov, J., Nakane, T., Forsberg, B. O., Kimanius, D., Hagen, W. J., Lindahl, E., & Scheres, S. H. (2018) · eLife · doi:10.7554/elife.42166 · Cited by 4,621
Self-citationReal-time cryo-electron microscopy data preprocessing with Warp
Tegunov, D., & Cramer, P. (2019) · Nature Methods · doi:10.1038/s41592-019-0580-y · Cited by 1,332
Structures and distributions of SARS-CoV-2 spike proteins on intact virions
Ke, Z., Oton, J., Qu, K., Cortese, M., Zila, V., McKeane, L., Nakane, T., Zivanov, J., Neufeldt, C. J., Cerikan, B., et al. (2020) · Nature · doi:10.1038/s41586-020-2665-2 · Cited by 1,149
Self-citationAutomated tilt series alignment and tomographic reconstruction in IMOD
Mastronarde, D. N., & Held, S. R. (2017) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.07.011 · Cited by 825
Hagen, W. J. H., Wan, W., & Briggs, J. A. G. (2017) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.06.007 · Cited by 806
Toward dynamic structural biology: Two decades of single-molecule Förster resonance energy transfer
Lerner, E., Cordes, T., Ingargiola, A., Alhadid, Y., Chung, S., Michalet, X., & Weiss, S. (2018) · Science · doi:10.1126/science.aan1133 · Cited by 569
Processing of Structurally Heterogeneous Cryo-EM Data in RELION
Scheres, S. H. W. (2016) · Methods in Enzymology · doi:10.1016/bs.mie.2016.04.012 · Cited by 549
Self-citationmTORC1 Controls Phase Separation and the Biophysical Properties of the Cytoplasm by Tuning Crowding
Delarue, M., Brittingham, G. P., Pfeffer, S., Surovtsev, I. V., Pinglay, S., Kennedy, K. J., Schaffer, M., Gutierrez, J. I., Sang, D., Poterewicz, G., et al. (2018) · Cell · doi:10.1016/j.cell.2018.05.042 · Cited by 535
Multi-particle cryo-EM refinement with M visualizes ribosome-antibiotic complex at 3.5 Å in cells
Tegunov, D., Xue, L., Dienemann, C., Cramer, P., & Mahamid, J. (2021) · Nature Methods · doi:10.1038/s41592-020-01054-7 · Cited by 509
Integrative structure and functional anatomy of a nuclear pore complex
Kim, S. J., Fernandez-Martinez, J., Nudelman, I., Shi, Y., Zhang, W., Raveh, B., Herricks, T., Slaughter, B. D., Hogan, J. A., Upla, P., et al. (2018) · Nature · doi:10.1038/nature26003 · Cited by 490
In-cell architecture of an actively transcribing-translating expressome
O’Reilly, F. J., Xue, L., Graziadei, A., Sinn, L., Lenz, S., Tegunov, D., Blötz, C., Singh, N., Hagen, W. J. H., Cramer, P., et al. (2020) · Science · doi:10.1126/science.abb3758 · Cited by 284
Cryo-EM shows how dynactin recruits two dyneins for faster movement
Urnavicius, L., Lau, C. K., Elshenawy, M. M., Morales-Rios, E., Motz, C., Yildiz, A., & Carter, A. P. (2018) · Nature · doi:10.1038/nature25462 · Cited by 283
emClarity: software for high-resolution cryo-electron tomography and subtomogram averaging
Himes, B. A., & Zhang, P. (2018) · Nature Methods · doi:10.1038/s41592-018-0167-z · Cited by 283
Cryo-Electron Tomography and Subtomogram Averaging
Wan, W., & Briggs, J. A. G. (2016) · Methods in Enzymology · doi:10.1016/bs.mie.2016.04.014 · Cited by 278
Bharat, T. A. M., & Scheres, S. H. W. (2016) · Nature Protocols · doi:10.1038/nprot.2016.124 · Cited by 261
Self-citationGrushin, K., Kalyana Sundaram, R. V., Sindelar, C. V., & Rothman, J. E. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2121259119 · Cited by 66
Determinants shaping the nanoscale architecture of the mouse rod outer segment
Pöge, M., Mahamid, J., Imanishi, S. S., Plitzko, J. M., Palczewski, K., & Baumeister, W. (2021) · eLife · doi:10.7554/elife.72817 · Cited by 50
CryoDRGN-AI: neural ab initio reconstruction of challenging cryo-EM and cryo-ET datasets
Levy, A., Raghu, R., Feathers, J. R., Grzadkowski, M., Poitevin, F., Johnston, J. D., Vallese, F., Clarke, O. B., Wetzstein, G., & Zhong, E. D. (2025) · Nature Methods · doi:10.1038/s41592-025-02720-4 · Cited by 25
Hastie, K. M., Salie, Z. L., Ke, Z., Halfmann, P. J., DeWald, L. E., McArdle, S., Grinyó, A., Davidson, E., Schendel, S. L., Hariharan, C., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-56452-2 · Cited by 9
Metadata
- Authors
- Bharat, T. A. M., Russo, C. J., Löwe, J., Passmore, L. A., & Scheres, S. H. W.
- Venue
- Structure
- Publisher
- Elsevier BV
- Published
- 2015-09
- Volume
- 23
- Issue
- 9
- Pages
- 1743-1753
- ISSN
- 0969-2126 (ISSN-L)
- OpenAlex
- W1885115521
- Cited by
- 195
- References
- 7
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.