Hot corrosion behaviour of HVOF-sprayed Cr 3 C 2 -NiCrMoNbAl coating
The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The protective oxides for the Cr3C2–NiCrMoNbAl coating were more complex, which included Cr2O3, NiO, NiCr2O4, Al2O3, MoO, and NbO.”
From High Temperature Corrosion Resistant and Anti-slagging Coatings for Boilers: A Review (2024) · cites this paper as [102]
In the citing paper
“The thickness loss of these coatings after corrosion was approximately 70 μm and 200 μm out of almost 400 μm thickness of as-sprayed coatings, respectively.”
From High Temperature Corrosion Resistant and Anti-slagging Coatings for Boilers: A Review (2024) · cites this paper as [102]
In the citing paper
“It was found that HVOF Cr3C2–NiCrMoNbAl coating provided superior corrosion resistance to the HVOF Cr3C2–NiCr counterpart.”
From High Temperature Corrosion Resistant and Anti-slagging Coatings for Boilers: A Review (2024) · cites this paper as [102]
In the citing paper
“During high temperature corrosion, a protective layer of Cr2O3 and NiCr2O4 was formed on the surface of the Cr3C2–NiCr coating.”
From High Temperature Corrosion Resistant and Anti-slagging Coatings for Boilers: A Review (2024) · cites this paper as [102]
Citations
Cites
The implications of chlorine-associated corrosion on the operation of biomass-fired boilers
Nielsen, H. P., Frandsen, F. J., Dam-Johansen, K., & Baxter, L. L. (2000) · Progress in Energy and Combustion Science · doi:10.1016/s0360-1285(00)00003-4 · Cited by 785
Grabke, H. J., Reese, E., & Spiegel, M. (1995) · Corrosion Science · doi:10.1016/0010-938x(95)00011-8 · Cited by 537
Zahs, A., Spiegel, M., & Grabke, H. J. (2000) · Corrosion Science · doi:10.1016/s0010-938x(99)00142-0 · Cited by 365
High temperature corrosion of coatings and boiler steels below chlorine-containing salt deposits
Uusitalo, M. A., Vuoristo, P. M. J., & Mäntylä, T. A. (2004) · Corrosion Science · doi:10.1016/j.corsci.2003.09.026 · Cited by 260
Deposition and high temperature corrosion in a 10 MW straw fired boiler
Michelsen, H. P., Frandsen, F., Dam-Johansen, K., & Larsen, O. H. (1998) · Fuel Processing Technology · doi:10.1016/s0378-3820(97)00062-3 · Cited by 258
The characterization of passive films on chromium electrodes by XPS
Stypula, B., & Stoch, J. (1994) · Corrosion Science · doi:10.1016/0010-938x(94)90014-0 · Cited by 197
Corrosion behaviour of various model alloys with NaCl–KCl coating
Li, Y. S., Spiegel, M., & Shimada, S. (2005) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2005.03.015 · Cited by 181
Self-citationIshitsuka, T., & Nose, K. (2002) · Corrosion Science · doi:10.1016/s0010-938x(01)00059-2 · Cited by 177
Thermally sprayed coatings resistant to erosion and corrosion for power plant boilers - A review
Szymański, K., Hernas, A., Moskal, G., & Myalska, H. (2015) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2014.10.046 · Cited by 172
Skrifvars, B.-J., Backman, R., Hupa, M., Salmenoja, K., & Vakkilainen, E. (2008) · Corrosion Science · doi:10.1016/j.corsci.2008.01.010 · Cited by 155
Kamal, S., Jayaganthan, R., Prakash, S., & Kumar, S. (2007) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2007.09.019 · Cited by 154
Kim, Y. C., Park, H., Chun, J. S., & Lee, W.-J. (1994) · Thin Solid Films · doi:10.1016/0040-6090(94)90238-0 · Cited by 149
Matthews, S. J., Hyland, M. H., & James, B. (2003) · Acta Materialia · doi:10.1016/s1359-6454(03)00254-4 · Cited by 144
Matthews, S. J., James, B., & Hyland, M. H. (2013) · Corrosion Science · doi:10.1016/j.corsci.2013.01.030 · Cited by 140
High temperature corrosion of coatings and boiler steels in oxidizing chlorine-containing atmosphere
Uusitalo, M. A., Vuoristo, P. M. J., & Mäntylä, T. (2003) · Materials Science and Engineering A · doi:10.1016/s0921-5093(02)00537-3 · Cited by 140
Corrosion of superheater materials in a waste-to-energy plant
Viklund, P., Hjörnhede, A., Henderson, P., Stålenheim, A., & Pettersson, R. F. A. (2011) · Fuel Processing Technology · doi:10.1016/j.fuproc.2011.06.017 · Cited by 140
The role of chlorine in high temperature corrosion in waste-to-energy plants
Sorell, G. (1997) · Materials at High Temperatures · doi:10.1080/09603409.1997.11689546 · Cited by 136
Kamal, S., Jayaganthan, R., & Prakash, S. (2008) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2008.09.031 · Cited by 132
Chatha, S. S., Sidhu, H. S., & Sidhu, B. S. (2012) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2012.01.060 · Cited by 132
Sidhu, T. S., Prakash, S., & Agrawal, R. D. (2006) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2005.12.030 · Cited by 131
Sajjadi, S. A., Zebarjad, S. M., Guthrie, R. I. L., & Isac, M. (2005) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2005.04.021 · Cited by 128
Sidhu, T. S., Prakash, S., & Agrawal, R. D. (2005) · Acta Materialia · doi:10.1016/j.actamat.2005.10.009 · Cited by 116
Comparative investigation on HVOF sprayed carbide-based coatings
Xie, M., Zhang, S., & Li, M. (2013) · Applied Surface Science · doi:10.1016/j.apsusc.2013.03.010 · Cited by 114
Hong, S., Wu, Y., Wang, Q., Ying, G., Li, G., Gao, W., Wang, B., & Guo, W. (2013) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2013.03.020 · Cited by 110
High temperature corrosion of coatings and boiler steels in reducing chlorine-containing atmosphere
Uusitalo, M. A., Vuoristo, P. M. J., & Mäntylä, T. (2002) · Surface and Coatings Technology · doi:10.1016/s0257-8972(02)00472-3 · Cited by 108
Matthews, S. J., & James, B. (2010) · Journal of Thermal Spray Technology · doi:10.1007/s11666-010-9518-8 · Cited by 107
Li, L., Li, G., Wang, H., Kang, J., Xu, Z., & Wang, H. (2015) · Applied Surface Science · doi:10.1016/j.apsusc.2015.08.019 · Cited by 105
Poirier, D., Legoux, J.-G., & Lima, R. S. (2012) · Journal of Thermal Spray Technology · doi:10.1007/s11666-012-9833-3 · Cited by 103
Kawahara, Y. (2007) · Journal of Thermal Spray Technology · doi:10.1007/s11666-006-9012-5 · Cited by 102
High-Temperature Corrosion Studies of HVOF-Sprayed Cr3C2-NiCr Coating on SAE-347H Boiler Steel
Kaur, M., Singh, H., & Prakash, S. (2009) · Journal of Thermal Spray Technology · doi:10.1007/s11666-009-9371-9 · Cited by 88
Sidhu, T. S., Malik, A., Prakash, S., & Agrawal, R. D. (2007) · Journal of Thermal Spray Technology · doi:10.1007/s11666-007-9106-8 · Cited by 79
Oksa, M., Auerkari, P., Salonen, J., & Varis, T. (2014) · Fuel Processing Technology · doi:10.1016/j.fuproc.2014.04.006 · Cited by 78
Reduction of superheater corrosion by co-firing risky biomass with sewage sludge
Aho, M. J., Yrjas, P., Taipale, R., Hupa, M. M., & Silvennoinen, J. (2010) · Fuel · doi:10.1016/j.fuel.2010.01.023 · Cited by 74
Oksa, M., Tuurna, S., & Varis, T. (2013) · Journal of Thermal Spray Technology · doi:10.1007/s11666-013-9928-5 · Cited by 69
Souza, V. A. D., & Neville, A. (2006) · Journal of Thermal Spray Technology · doi:10.1361/105996306x92677 · Cited by 68
Microstructure and Mechanical Properties of HVOF Sprayed Nanocrystalline Cr3C2-25(Ni20Cr) Coating
Roy, M., Pauschitz, A., Bernardi, J., Koch, T., & Franek, F. (2006) · Journal of Thermal Spray Technology · doi:10.1361/105996306x124374 · Cited by 67
The effects of post-treatment on the hot corrosion behavior of the HVOF-sprayed Cr3C2–NiCr coating
Chatha, S. S., Sidhu, H. S., & Sidhu, B. S. (2012) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2012.04.026 · Cited by 63
Paul, S., & Harvey, M. D. F. (2013) · Journal of Thermal Spray Technology · doi:10.1007/s11666-012-9820-8 · Cited by 52
Guo, X., Planche, M.-P., Chen, J., & Liao, H. (2013) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2013.09.029 · Cited by 52
Properties of WC–FeCrAl coatings manufactured by different high velocity thermal spray processes
Bolelli, G., Hulka, I., Koivuluoto, H., Lusvarghi, L., Milanti, A., Niemi, K., & Vuoristo, P. M. J. (2014) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2014.03.021 · Cited by 48
Kawahara, Y., & Kira, M. (1997) · CORROSION · doi:10.5006/1.3280466 · Cited by 46
Matthews, S. J., & James, B. (2010) · Journal of Thermal Spray Technology · doi:10.1007/s11666-010-9519-7 · Cited by 45
Viklund, P., Pettersson, R., Hjörnhede, A., Henderson, P., & Sjövall, P. (2009) · Corrosion Engineering, Science and Technology · doi:10.1179/174327809x419203 · Cited by 37
Hot corrosion of carbon-alloyed Fe3Al-based iron aluminides
Das, D., Balasubramaniam, R., & Mungole, M. N. (2002) · Materials Science and Engineering A · doi:10.1016/s0921-5093(02)00072-2 · Cited by 37
Thermal Spray Coatings for High-Temperature Corrosion Protection in Biomass Co-Fired Boilers
Oksa, M., Metsäjoki, J., & Kärki, J. (2014) · Journal of Thermal Spray Technology · doi:10.1007/s11666-014-0155-5 · Cited by 36
HVOF Coating Case Study for Power Plant Process Control Ball Valve Application
Vernhes, L., Lee, D. A., Poirier, D., Li, D., & Klemberg-Sapieha, J. E. (2013) · Journal of Thermal Spray Technology · doi:10.1007/s11666-013-9978-8 · Cited by 33
Applications of coatings in coal-fired energy systems
Natesan, K. (1993) · Surface and Coatings Technology · doi:10.1016/0257-8972(93)90251-i · Cited by 31
Liu, X.-B., Fu, G., Liu, S., Shi, S., He, X., & Wang, M. (2011) · Nuclear Engineering and Design · doi:10.1016/j.nucengdes.2011.09.021 · Cited by 28
Weng, F., Yu, H., Wan, K., & Chen, C. (2014) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2014.282 · Cited by 28
The mechanical properties of surface scales on nickel-base superalloys—II. Contaminant corrosion
Johnson, J. B., Nicholls, J. R., Hurst, R. C., & Hancock, P. (1978) · Corrosion Science · doi:10.1016/s0010-938x(78)80028-6 · Cited by 27
Oksa, M., Varis, T., & Ruusuvuori, K. (2014) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2014.04.025 · Cited by 26
Kamali, R., & Binesh, A. R. (2009) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2009.06.015 · Cited by 26
Niaz, A., & Bakare, M. S. (2015) · Corrosion Reviews · doi:10.1515/corrrev-2014-0037 · Cited by 10
Cited by
A review on molten sulfate salts induced hot corrosion
Hu, S., Finklea, H., & Liu, X. (2021) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2021.03.013 · Cited by 183
Wang, K., Zhu, J., Wang, H., Yang, K., Zhu, Y., Qing, Y., Ma, Z., Gao, L., Liu, Y., Wei, S., et al. (2022) · Journal of Advanced Ceramics · doi:10.1007/s40145-022-0630-2 · Cited by 166
Hot corrosion behavior of HVOF-sprayed Cr 3 C 2 -WC-NiCoCrMo coating
Zhou, W., Zhou, K., Deng, C., Zeng, K., & Li, Y. (2017) · Ceramics International · doi:10.1016/j.ceramint.2017.04.109 · Cited by 80
Self-citationEffects of loads on corrosion-wear synergism of NiCoCrAlYTa coating in artificial seawater
Liu, X., Zhao, X., An, Y., Hou, G., Li, S., Deng, W. Y., Zhou, H., & Chen, J. (2017) · Tribology International · doi:10.1016/j.triboint.2017.10.019 · Cited by 61
Sadeghi, E., Markocsan, N., & Joshi, S. V. (2019) · Journal of Thermal Spray Technology · doi:10.1007/s11666-019-00939-0 · Cited by 60
Metadata
- Authors
- Zhou, W., Zhou, K., Deng, C., Zeng, K., & Li, Y.
- Affiliations
- Central South University (CN)
- Guangdong Institute of New Materials (CN)
- Corresponding author
- Zhou, Wuxi
- ORCID
- Deng, Chunming
- Venue
- Surface and Coatings Technology
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 309
- Pages
- 849-859
- ISSN
- 0257-8972 (ISSN-L)
- OpenAlex
- W2544440323
- Cited by
- 62
- References
- 53
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 9 · 2023: 7 · 2022: 6 · 2021: 6 · 2020: 10 · 2019: 7 · 2018: 1 · 2017: 3
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Surface and Coatings Technology (publishedVersion)
- Funders
- Natural Science Foundation of Guangdong Province (2016A030312015)
- Guangdong Science and Technology Programming (2013B050800031, 2014B050502008, 2015B07070124)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › High-Temperature Coating Behaviors
- Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
- Physical Sciences › Materials Science › Ceramics and Composites › Advanced ceramic materials synthesis
- Keywords
- hot corrosion, HVOF spraying, cyclic corrosion, P91 steel, coating deposition efficiency, coating porosity, oxide scale formation, spinel oxides, corrosion resistance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.