CoChat

The System for Telementoring with Augmented Reality (STAR): A head-mounted display to improve surgical coaching and confidence in remote areas

Open access
Rojas-Muñoz, Edgar, Cabrera, Maria E., Lin, Chengyuan, Andersen, Daniel, Popescu, Voicu, Anderson, Kathryn, Zarzaur, Ben L., Mullis, Brian, Wachs, Juan P. · 2020 · Surgery
Cited by 77

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND The surgical workforce particularly in rural regions needs novel approaches to reinforce the skills and confidence of health practitioners. Although conventional telementoring systems have proven beneficial to address this gap, the benefits of platforms of augmented reality-based telementoring in the coaching and confidence of medical personnel are yet to be evaluated. METHODS A total of 20 participants were guided by remote expert surgeons to perform leg fasciotomies on cadavers under one of two conditions: (1) telementoring (with our System for Telementoring with Augmented Reality) or (2) independently reviewing the procedure beforehand. Using the Individual Performance Score and the Weighted Individual Performance Score, two on-site, expert surgeons evaluated the participants. Postexperiment metrics included number of errors, procedure completion time, and self-reported confidence scores. A total of six objective measurements were obtained to describe the self-reported confidence scores and the overall quality of the coaching. Additional analyses were performed based on the participants' expertise level. RESULTS Participants using the System for Telementoring with Augmented Reality received 10% greater Weighted Individual Performance Score (P = .03) and performed 67% fewer errors (P = .04). Moreover, participants with lower surgical expertise that used the System for Telementoring with Augmented Reality received 17% greater Individual Performance Score (P = .04), 32% greater Weighted Individual Performance Score (P < .01) and performed 92% fewer errors (P < .001). In addition, participants using the System for Telementoring with Augmented Reality reported 25% more confidence in all evaluated aspects (P < .03). On average, participants using the System for Telementoring with Augmented Reality received augmented reality guidance 19 times on average and received guidance for 47% of their total task completion time. CONCLUSION Participants using the System for Telementoring with Augmented Reality performed leg fasciotomies with fewer errors and received better performance scores. In addition, participants using the System for Telementoring with Augmented Reality reported being more confident when performing fasciotomies under telementoring. Augmented Reality Head-Mounted Display-based telementoring successfully provided confidence and coaching to medical personnel.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.surg.2019.11.008

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 77

Metadata

Authors
Rojas-Muñoz, E., Cabrera, M. E., Lin, C., Andersen, D., Popescu, V., Anderson, K., Zarzaur, B. L., Mullis, B., & Wachs, J. P.
Venue
Surgery
Publisher
Elsevier BV
Published
2020-04
Volume
167
Issue
4
Pages
724-731
ISSN
0039-6060 (ISSN-L)
OpenAlex
W3000273617
Cited by
77
References
3
FWCI
9.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The System for Telementoring with Augmented Reality (STAR): A head-mounted display to improve surgical coaching and confidence in remote areas. https://app.cochat.ai/papers/10.1016/j.surg.2019.11.008
The paper
Rojas-Muñoz, E., Cabrera, M. E., Lin, C., Andersen, D., Popescu, V., Anderson, K., Zarzaur, B. L., Mullis, B., & Wachs, J. P. (2020). The System for Telementoring with Augmented Reality (STAR): A head-mounted display to improve surgical coaching and confidence in remote areas. Surgery. https://doi.org/10.1016/j.surg.2019.11.008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.