Delivering ancillary services with data centres
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Regulation services are constantly active and data centers could adjust their consumption according to the signals sent by the grid operator every few seconds.”
From An overview of Demand Response: Key-elements and international experience (2017) · cites this paper as [82]
In the citing paper
“Data centers are also considered capable of providing a range of ancillary services [82].”
From An overview of Demand Response: Key-elements and international experience (2017) · cites this paper as [82]
In the citing paper
“Furthermore, by transitioning a number of active servers to the sleep state, data centers may provide short-term operating reserves or emergency DR.”
From An overview of Demand Response: Key-elements and international experience (2017) · cites this paper as [82]
Citations
Cites
The Case for Energy-Proportional Computing
Barroso, L. A., & Hölzle, U. (2007) · Computer · doi:10.1109/mc.2007.443 · Cited by 2,491
Vehicle-to-grid power fundamentals: Calculating capacity and net revenue
Kempton, W., & Tomić, J. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2004.12.025 · Cited by 2,323
Cutting the electric bill for internet-scale systems
Qureshi, A., Weber, R., Balakrishnan, H., Guttag, J., & Maggs, B. (2009) · Proceedings of the ACM SIGCOMM 2009 conference on Data communication · doi:10.1145/1592568.1592584 · Cited by 830
Hawaii international conference on system sciences
Schultz, E. E. (1992) · ACM SIGCHI Bulletin · doi:10.1145/134421.134436 · Cited by 517
Optimal power cost management using stored energy in data centers
Urgaonkar, R., Urgaonkar, B., Neely, M. J., & Sivasubramaniam, A. (2011) · ACM SIGMETRICS International Conference on Measurement and Modeling of Computer Systems (SIGMETRICS) · doi:10.1145/1993744.1993766 · Cited by 461
The spectrum of power from wind turbines
Apt, J. (2007) · Journal of Power Sources · doi:10.1016/j.jpowsour.2007.02.077 · Cited by 347
Proceedings of the 46th International Symposium on Computer Architecture
(2019) · doi:10.1145/3307650 · Cited by 320
GreenSlot: scheduling energy consumption in green datacenters
Goiri, Í., Le, K., Haque, M. E., Beauchea, R., Nguyen, T. D., Guitart, J., Torres, J., & Bianchini, R. (2011) · Proceedings of 2011 International Conference for High Performance Computing, Networking, Storage and Analysis · doi:10.1145/2063384.2063411 · Cited by 309
Mathiesen, B. V., & Lund, H. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20080049 · Cited by 288
Benefits and limitations of tapping into stored energy for datacenters
Govindan, S., Sivasubramaniam, A., & Urgaonkar, B. (2011) · Proceedings of the 38th annual international symposium on Computer architecture · doi:10.1145/2000064.2000105 · Cited by 223
Reducing electricity cost through virtual machine placement in high performance computing clouds
Le, K., Bianchini, R., Zhang, J., Jaluria, Y., Meng, J., & Nguyen, T. D. (2011) · Proceedings of 2011 International Conference for High Performance Computing, Networking, Storage and Analysis · doi:10.1145/2063384.2063413 · Cited by 199
Advancement of energy storage devices and applications in electrical power system
Smith, S. C., Sen, P. K., & Kroposki, B. (2008) · 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century · doi:10.1109/pes.2008.4596436 · Cited by 192
Air Emissions Due To Wind And Solar Power
Katzenstein, W., & Apt, J. (2008) · Environmental Science & Technology · doi:10.1021/es801437t · Cited by 176
Capping the brown energy consumption of Internet services at low cost
Le, K., Bianchini, R., Nguyen, T. D., Bilgir, O., & Martonosi, M. (2010) · International Conference on Green Computing · doi:10.1109/greencomp.2010.5598305 · Cited by 173
Long-Run Incremental Cost Pricing Based on Unused Capacity
Li, F., & Tolley, D. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.908469 · Cited by 151
Coordination of Cloud Computing and Smart Power Grids
Mohsenian-Rad, A.-H., & Leon‐Garcia, A. (2010) · IEEE International Conference on Smart Grid Communications (SmartGridComm) · doi:10.1109/smartgrid.2010.5622069 · Cited by 141
2008 IEEE Power Engineering Society General Meeting
(2008) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2008.4412945 · Cited by 124
SolarCore: Solar energy driven multi-core architecture power management
Li, C., Zhang, W., Cho, C.-B., & Li, T. (2011) · IEEE International Symposium on High-Performance Computer Architecture (HPCA) · doi:10.1109/hpca.2011.5749729 · Cited by 104
Integrating Renewable Energy Using Data Analytics Systems: Challenges and Opportunities.
Krioukov, A., Goebel, C., Alspaugh, S., Chen, Y., Culler, D., & Katz, R. H. (2011) · IEEE Data(base) Engineering Bulletin · Cited by 104
Capacity planning and power management to exploit sustainable energy
Gmach, D., Rolia, J., Bash, C. E., Chen, Y., Christian, T., Shah, A. J., Sharma, R. K., & Wang, Z. (2010) · International Conference on Network and Service Management (CNSM) · doi:10.1109/cnsm.2010.5691329 · Cited by 86
Load Response Fundamentally Matches Power System Reliability Requirements
Kirby, B. J. (2007) · 2007 IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2007.386227 · Cited by 78
GreenSlot: Scheduling energy consumption in green datacenters
Goiri, Beauchea, Lê, Nguyen, Haque, Guitart, Torrès, & Bianchini (2011) · IEEE International Conference on High Performance Computing, Data, and Analytics · Cited by 77
International Green Computing Conference
(2014) · doi:10.1109/igcc34527.2014 · Cited by 59
Optimal power cost management using stored energy in data centers
Urgaonkar, R., Urgaonkar, B., Neely, M. J., & Sivasubramaniam, A. (2011) · ACM SIGMETRICS Performance Evaluation Review · doi:10.1145/2007116.2007138 · Cited by 57
Trends and effects of energy proportionality on server provisioning in data centers
Varsamopoulos, G., Abbasi, Z., & Gupta, S. K. S. (2010) · IEEE International Conference on High Performance Computing, Data, and Analytics · doi:10.1109/hipc.2010.5713198 · Cited by 52
Power-aware resource allocation in high-end systems via online simulation
Lawson, B. G., & Evgenia Smirni, A. (2005) · International Conference on Supercomputing · doi:10.1145/1088149.1088179 · Cited by 48
Ancillary-service details: operating reserves
Lab., T. (. S. O. R. N., Hirst, E., USDOE Assistant Secretary for Energy Efficiency and Renewable Energy, W., & Kirby, B. (1997) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/614919 · Cited by 40
Wang, P., Zareipour, H., & Rosehart, W. (2011) · Energy Policy · doi:10.1016/j.enpol.2011.03.008 · Cited by 37
Self-citationProceedings of the 20th annual international conference on Supercomputing
Egan, G. K., & Muraoka, Y. (2006) · doi:10.1145/1183401 · Cited by 36
Leveraging thermal storage to cut the electricity bill for datacenter cooling
Wang, Y., Wang, X., & Zhang, Y. (2011) · International Conference on Power aware computing and systems · doi:10.1145/2039252.2039260 · Cited by 35
2009 International Conference on High Performance Computing (HiPC)
(2009) · doi:10.1109/hipc16042.2009 · Cited by 34
Energy-cost-aware scheduling of HPC workloads
Aikema, D., Kiddle, C., & Simmonds, R. (2011) · IEEE International Symposium on a World of Wireless, Mobile and Multimedia Networks (WoWMoM) · doi:10.1109/wowmom.2011.5986476 · Cited by 25
Self-citationProceedings of the Workshop on Power-Aware Computing and Systems
(2015) · doi:10.1145/2818613 · Cited by 15
Electrical cost savings and clean energy usage potential for HPC workloads
Aikema, D., & Simmonds, R. (2011) · IEEE International Symposium on Sustainable Systems and Technology · doi:10.1109/issst.2011.5936911 · Cited by 13
Self-citationIntegrating Wind Power: Can Controllable Load Substitute for Transmission Upgrades?
Mount, T. D., Lamadrid, A. J., Maneevitjit, S., Zimmerman, R. D., & Thomas, R. J. (2011) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.2011.246 · Cited by 3
Research works printed but not linked: 2
- J.G. Koomey, Growth in data center electricity use 2005 to 2010, Tech. rep., Analytics Press at the request of the New York Times, Oakland, CA, August 2011.
- J. Pfeifenberger, A. Hajos, Demand response review, Tech. rep., The Brattle Group, March 2011.
Cited by
An overview of Demand Response: Key-elements and international experience
Paterakis, N. G., Erdinç, O., & Catalão, J. P. S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.167 · Cited by 640
Kumar, A., Meena, N. K., Singh, A. R., Deng, Y., He, X., Bansal, R. C., & Kumar, P. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113503 · Cited by 160
A survey of challenges and solutions for the integration of renewable energy in datacenters
Rostirolla, G., Grange, L., Thi, M.-T., Stolf, P., Pierson, J., Costa, G. D., Baudic, G., Haddad, M., Kassab, A., Nicod, J., et al. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111787 · Cited by 112
Review of energy efficiency and technological advancements in data center power systems
Khosravi, A., Sandoval, O. R., Taslimi, M. S., Sahrakorpi, T., Amorim, G., & Pabón, J. J. G. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114834 · Cited by 93
Exploiting data centres energy flexibility in smart cities: Business scenarios
Cioara, T., Anghel, I. M., Salomie, I., Antal, M., Pop, C. D., Bertoncini, M., Arnone, D., & Pop, F. (2018) · Information Sciences · doi:10.1016/j.ins.2018.07.010 · Cited by 48
Metadata
- Authors
- Aikema, D., Simmonds, R., & Zareipour, H.
- Affiliations
- University of Calgary (CA)
- Corresponding author
- Aikema, David
- Venue
- Sustainable Computing: Informatics and Systems
- Publisher
- Elsevier BV
- Published
- 2013-09
- Volume
- 3
- Issue
- 3
- Pages
- 172-182
- ISSN
- 2210-5379 (ISSN-L)
- OpenAlex
- W2047921657
- Cited by
- 8
- References
- 37
- Citations by year
- 2024: 1 · 2021: 1 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 1 · 2015: 1
- FWCI
- 0.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Sustainable Computing Informatics and Systems (publishedVersion)
- Funders
- Canarie
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
- Physical Sciences › Computer Science › Hardware and Architecture › Energy Efficiency in Computing
- Physical Sciences › Computer Science › Information Systems › Cloud Computing and Resource Management
- Keywords
- ancillary services, data centers, energy cost reduction, electricity pricing, quality of service
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.