Ultrasound-assisted leaching-dispersive solid-phase extraction followed by liquid–liquid microextraction for the determination of polybrominated diphenyl ethers in sediment samples by gas chromatography–tandem mass spectrometry
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Ultrasound-assisted leaching-dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction (USAL-DSPE-DLLME) technique has been developed as a new analytical approach for extracting, cleaning up and preconcentrating polybrominated diphenyl ethers (PBDEs) from sediment samples prior gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. In the first place, PBDEs were leached from sediment samples by using acetone. This extract was cleaned-up by DSPE using activated silica gel as sorbent material. After clean-up, PBDEs were preconcentrated by using DLLME technique. Thus, 1 mL acetone extract (disperser solvent) and 60 microL carbon tetrachloride (extraction solvent) were added to 5 mL ultrapure water and a DLLME technique was applied. Several variables that govern the proposed technique were studied and optimized. Under optimum conditions, the method detection limits (MDLs) of PBDEs calculated as three times the signal-to-noise ratio (S/N) were within the range 0.02-0.06 ng g(-1). The relative standard deviations (RSDs) for five replicates were <9.8%. The calibration graphs were linear within the concentration range of 0.07-1000 ng g(-1) for BDE-47, 0.09-1000 ng g(-1) for BDE-100, 0.10-1000 ng g(-1) for BDE-99 and 0.19-1000 ng g(-1) for BDE-153 and the coefficients of estimation were > or =0.9991. Validation of the methodology was carried out by standard addition method at two concentration levels (0.25 and 1 ng g(-1)) and by comparing with a reference Soxhlet technique. Recovery values were > or =80%, which showed a satisfactory robustness of the analytical methodology for determination of low PBDEs concentration in sediment samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anastassiades, M., Lehotay, S. J., Štajnbaher, D., & Schenck, F. J. (2003) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/86.2.412 · Cited by 5,670
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Wu, Q., Wang, C., Liu, Z., Wu, C., Zeng, X., Wen, J., & Wang, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.062 · Cited by 174
Zhao, E., Zhao, W., Han, L., Jiang, S., & Zhou, Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.069 · Cited by 170
Liu, X., Li, J., Zhao, Z., Zhang, W., Lin, K., Huang, C., & Wang, X. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.12.092 · Cited by 106
Hu, J., Fu, L., Zhao, X., Liu, X., Wang, H., Wang, X., & Dai, L. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.02.055 · Cited by 71
Coburn, C. G., Curras-Collazo, M. C., & Kodavanti, P. R. S. (2007) · Toxicological Sciences · doi:10.1093/toxsci/kfm086 · Cited by 45
Cited by
Agriculture Development, Pesticide Application and Its Impact on the Environment
Tudi, M., Daniel Ruan, H., Wang, L., Lyu, J., Sadler, R., Connell, D., Chu, C., & Phung, D. T. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18031112 · Cited by 2,658
Development of dispersive micro-solid phase extraction based on micro and nano sorbents
Khezeli, T., & Daneshfar, A. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.01.004 · Cited by 327
Trends in liquid-phase microextraction, and its application to environmental and biological samples
Han, D., & Row, K. H. (2012) · Microchimica Acta · doi:10.1007/s00604-011-0678-0 · Cited by 175
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Mohebbi, A., Yaripour, S., Farajzadeh, M. A., & Afshar Mogaddam, M. R. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.08.022 · Cited by 94
Metadata
- Authors
- Fontana, A. R., Lana, N. B., Martinez, L. D., & Altamirano, J. C.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2010-06
- Volume
- 82
- Issue
- 1
- Pages
- 359-366
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2022921810
- Cited by
- 72
- References
- 7
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound-assisted leaching-dispersive solid-phase extraction followed by liquid–liquid microextraction for the determination of polybrominated diphenyl ethers in sediment samples by gas chromatography–tandem mass spectrometry. https://app.cochat.ai/papers/10.1016/j.talanta.2010.04.050
- The paper
- Fontana, A. R., Lana, N. B., Martinez, L. D., & Altamirano, J. C. (2010). Ultrasound-assisted leaching-dispersive solid-phase extraction followed by liquid–liquid microextraction for the determination of polybrominated diphenyl ethers in sediment samples by gas chromatography–tandem mass spectrometry. Talanta. https://doi.org/10.1016/j.talanta.2010.04.050
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.