CoChat

A rapid UHPLC-MS/MS method for simultaneous quantitation of 23 perfluoroalkyl substances (PFAS) in estuarine water

Mulabagal, Vanisree, Liu, Lan, Qi, Jingyi, Wilson, Caleb, Hayworth, Joel S. · 2018 · Talanta
Cited by 79

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Per- and polyfluoroalkyl substances (PFAS) represent a large group of synthetic organic compounds which, as a result of their unique chemical properties, render them extremely recalcitrant to environmental degradation. Research concerning the environmental, ecological, and human health effects of PFAS has focused on long aliphatic chain (> C7) compounds having no ether bonds. For new, less studied, or previously unknown PFAS (≤ C7 with ether bonds), there is little to no information about their environmental behavior, transport, fate, exposure, and toxicological effects. LC-MS/MS has proven effective for detection and quantitation of some PFAS, however, straightforward analytical methods for simultaneous trace quantitation of broad mixtures of PFAS in varied complex environmental media, available to a wide range of researchers and also suitable for routine monitoring, remain critical needs. Here we describe a simple, rapid, sensitive, and reproducible quantitative analytical method for trace analysis and monitoring of 23 PFAS in estuarine water, using ultra-high performance liquid chromatography-triple quadrupole mass spectrometry (UHPLC-MS/MS). The developed MRM method allows simultaneous trace quantitation of a broad mixture of PFAS, including 13 perfluoroalkyl carboxylic acids, 8 perfluoroalkyl sulfonates, and 2 short-chain perfluoroethers. The method provides better peak resolution and peak separation, and shorter run times (method separation/total run time: 6/8 min) compared to those of existing analytical methods. Percent recoveries for the validated method ranged from 78.54 to 112.61. LOD and LOQ values ranged from 0.48 to 1.68 pg/injection and 1.71 to 5.40 pg/injection, respectively. The validated method was used for quantitative PFAS analysis of estuarine water samples collected from 16 locations within the Perdido Bay estuary in coastal Alabama.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.talanta.2018.07.053

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 79

Metadata

Authors
Mulabagal, V., Liu, L., Qi, J., Wilson, C., & Hayworth, J. S.
Venue
Talanta
Publisher
Elsevier BV
Published
2018-12
Volume
190
Pages
95-102
ISSN
0039-9140 (ISSN-L)
OpenAlex
W2883774410
Cited by
79
References
13
FWCI
2.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A rapid UHPLC-MS/MS method for simultaneous quantitation of 23 perfluoroalkyl substances (PFAS) in estuarine water. https://app.cochat.ai/papers/10.1016/j.talanta.2018.07.053
The paper
Mulabagal, V., Liu, L., Qi, J., Wilson, C., & Hayworth, J. S. (2018). A rapid UHPLC-MS/MS method for simultaneous quantitation of 23 perfluoroalkyl substances (PFAS) in estuarine water. Talanta. https://doi.org/10.1016/j.talanta.2018.07.053

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.