Capture-SELEX for aptamer selection: A short review
The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
The emerging aptamer, developed through the systematic evolution of ligands by exponential enrichment (SELEX) process, has revolutionized and facilitated the discoveries in basic research. Among all SELEX technology, Capture-SELEX is a variant of the in vitro selection process, which is suitable for isolating aptamers against small molecules. Capture-SELEX library was developed to enable the immobilization of the oligonucleotides instead of the target molecules during the aptamer selection process. The review provides an update on the recent-advances in this new screening method with particular emphasis on key points of capture protocol and its applications. The limitations and the prospects of the Capture-SELEX are also discussed. We hope that present review will inspire more researchers to understand the selection problems from the perspective of Capture-SELEX. Moreover, it will open new pave to improve the efficiency and success of screening to meet the growing demand for aptasensor discovery in small molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Aptamers as targeted therapeutics: current potential and challenges
Zhou, J., & Rossi, J. (2017) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.199 · Cited by 2,221
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
SELEX—A (r)evolutionary method to generate high-affinity nucleic acid ligands
Stoltenburg, R., Reinemann, C., & Strehlitz, B. (2007) · Biomolecular Engineering · doi:10.1016/j.bioeng.2007.06.001 · Cited by 1,430
Current approaches in SELEX: An update to aptamer selection technology
Darmostuk, M., Rimpelova, S., Gbelcova, H., & Ruml, T. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.02.008 · Cited by 702
Wang, T., Chen, C., Larcher, L. M., Barrero, R. A., & Veedu, R. N. (2019) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.11.001 · Cited by 525
Challenges and Opportunities for Small Molecule Aptamer Development
McKeague, M., & DeRosa, M. C. (2012) · Journal of Nucleic Acids · doi:10.1155/2012/748913 · Cited by 466
In Vitro Selection of Structure‐Switching Signaling Aptamers
Nutiu, R., & Li, Y. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200461848 · Cited by 455
Gopinath, S. C. B. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0826-2 · Cited by 392
Cited by
Recent Trends in Biosensors for Environmental Quality Monitoring
Gavrilaș, S., Ursachi, C. Ș., Perța-Crișan, S., & Munteanu, F.-D. (2022) · Sensors · doi:10.3390/s22041513 · Cited by 202
Aptamer-based biosensors: from SELEX to biomedical diagnostics
Stangherlin, S., Lui, N., Lee, J. H., & Liu, J. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118349 · Cited by 168
Metadata
- Authors
- Lyu, C., Khan, I. M., & Wang, Z.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 229
- Pages
- 122274
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W3134094763
- Cited by
- 250
- References
- 66
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.