Aptamer-based biosensors: from SELEX to biomedical diagnostics
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
With excellent binding properties, stability, programmable structures, and ease of modification, DNA aptamers are promising for developing biosensors for both point-of-care and continuous monitoring applications. Over the last few years, significant progress has been made in the selection of high-quality aptamers for important target molecules, fundamental understanding of aptamer binding, and biosensor development, especially in the form of portable sensors, continuous in vivo monitoring and wearable devices. For small molecule targets, library-immobilization-based selection has yielded over 100 high-quality short aptamers with well-defined secondary structures. For protein targets, engineering polyvalent aptamers and slow off-rate aptamers can better mimic the binding properties of antibodies allowing extensive washing and binding in complex sample matrices. New methods in cell-SELEX have also provided insights into the isolation of aptamers against rare surface biomarkers. This review aims to capture these developments, which will build a solid foundation for future research and development in aptamer-based biosensors. • New aptamer selection methods reviewed for small molecules, proteins and cells. • Wearable biosensors, in vivo continuous monitoring devices and lateral flow devices based on aptamers described. • Critical comparison of different aptamer selection and sensing strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mfold web server for nucleic acid folding and hybridization prediction
Zuker, M. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg595 · Cited by 13,404
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Aptamer-Based Multiplexed Proteomic Technology for Biomarker Discovery
Gold, L., Ayers, D., Bertino, J., Bock, C., Bock, A., Brody, E. N., Carter, J., Dalby, A. B., Eaton, B. E., Fitzwater, T., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015004 · Cited by 1,754
Analysis of aptamer discovery and technology
Dunn, M. R., Jimenez, R. M., & Chaput, J. C. (2017) · Nature Reviews Chemistry · doi:10.1038/s41570-017-0076 · Cited by 938
Metadata
- Authors
- Stangherlin, S., Lui, N., Lee, J. H., & Liu, J.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2025-10
- Volume
- 191
- Pages
- 118349
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W4411474706
- Cited by
- 168
- References
- 4
- FWCI
- 42.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aptamer-based biosensors: from SELEX to biomedical diagnostics. https://app.cochat.ai/papers/10.1016/j.trac.2025.118349
- The paper
- Stangherlin, S., Lui, N., Lee, J. H., & Liu, J. (2025). Aptamer-based biosensors: from SELEX to biomedical diagnostics. TrAC Trends in Analytical Chemistry. https://doi.org/10.1016/j.trac.2025.118349
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.