CoChat

Development of an electrochemical biosensor for non-invasive cholesterol monitoring via microneedle-based interstitial fluid extraction

Kim, JeeYoung, Kim, Mi Yeon, Han, Yuna, Lee, Ga Yeong, Kim, Da Hyeon, Heo, Yun Jung, Park, Min · 2024 · Talanta
Cited by 18

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

In this study, we present the development of an innovative electrochemical biosensor integrated into a microneedle-based system for non-invasive and sensitive quantification of cholesterol levels in interstitial fluid (ISF). The biosensor employs a graphene-based electrode with a polyelectrolyte interlayer to immobilize cholesterol oxidase (ChOx), enabling selective cholesterol detection. Graphene oxide is electrochemically reduced to form a conductive layer, and PANI is chosen as the optimal polyelectrolyte for ChOx immobilization. The biosensor's performance is thoroughly evaluated, demonstrating excellent sensitivity, stability, and selectivity. Furthermore, the biosensor is successfully applied to skin-mimicking agarose gel and porcine skin, showcasing its potential for real-world interstitial fluid extraction and cholesterol monitoring. The integrated microneedle-based system offers a promising approach for non-invasive monitoring of cholesterol levels, with implications for personalized healthcare diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.talanta.2024.126771

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 6

  1. Ma, 2006, Cholesterol and human health, The Journal of American Science, 2, 46
  2. Friedel, 2023, Opportunities and challenges in the diagnostic utility of dermal interstitial fluid, Nat. Biomed. Eng., 1
  3. Jung, 2021, Microneedle for transdermal drug delivery: current trends and fabrication, Journal of pharmaceutical investigation, 1
  4. Rad, 2021, An overview of microneedle applications, materials, and fabrication methods, Beilstein J. Nanotechnol., 12, 1034
  5. Park, 2021, Biosensing technologies for chronic diseases, BioChip Journal, 1, 10.1007/s13206-021-00014-3 · DOI
  6. Tieu, 2023, Rapid and ultrasensitive detection of Staphylococcus aureus using a gold-interdigitated single-wave-shaped electrode (Au-ISWE) electrochemical biosensor, BioChip Journal, 1

Metadata

Authors
Kim, J., Kim, M. Y., Han, Y., Lee, G. Y., Kim, D. H., Heo, Y. J., & Park, M.
Venue
Talanta
Publisher
Elsevier BV
Published
2024-12
Volume
280
Pages
126771
ISSN
0039-9140
Cited by
18
References
36
Language
en
Licence
Funders
  • National Research Foundation of Korea
  • Ministry of Science, ICT and Future Planning (RS-2023-00207801, RS-2024-00410438, RS-2024-00354312)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.