Development of an electrochemical biosensor for non-invasive cholesterol monitoring via microneedle-based interstitial fluid extraction
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
In this study, we present the development of an innovative electrochemical biosensor integrated into a microneedle-based system for non-invasive and sensitive quantification of cholesterol levels in interstitial fluid (ISF). The biosensor employs a graphene-based electrode with a polyelectrolyte interlayer to immobilize cholesterol oxidase (ChOx), enabling selective cholesterol detection. Graphene oxide is electrochemically reduced to form a conductive layer, and PANI is chosen as the optimal polyelectrolyte for ChOx immobilization. The biosensor's performance is thoroughly evaluated, demonstrating excellent sensitivity, stability, and selectivity. Furthermore, the biosensor is successfully applied to skin-mimicking agarose gel and porcine skin, showcasing its potential for real-world interstitial fluid extraction and cholesterol monitoring. The integrated microneedle-based system offers a promising approach for non-invasive monitoring of cholesterol levels, with implications for personalized healthcare diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ferroptosis: a cell death connecting oxidative stress, inflammation and cardiovascular diseases
Yu, Y., Yan, Y., Niu, F., Wang, Y., Chen, X., Su, G., Liu, Y., Zhao, X., Qian, L., Liu, P., et al. (2021) · Cell Death Discovery · doi:10.1038/s41420-021-00579-w · Cited by 776
Chen, L., Tang, Y., Wang, K., Liu, C., & Luo, S. (2011) · Electrochemistry Communications · doi:10.1016/j.elecom.2010.11.033 · Cited by 761
Duan, Y., Gong, K., Xu, S., Zhang, F., Meng, X., & Han, J. (2022) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-022-01125-5 · Cited by 538
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Metabolomics and lipidomics in NAFLD: biomarkers and non-invasive diagnostic tests
Masoodi, M., Gastaldelli, A., Hyötyläinen, T., Arretxe, E., Alonso, C., Gaggini, M., Brosnan, J., Anstee, Q. M., Millet, O., Ortiz, P., et al. (2021) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-021-00502-9 · Cited by 451
Sampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Zhang, Y., Vittinghoff, E., Pletcher, M. J., Allen, N. B., Zeki Al Hazzouri, A., Yaffe, K., Balte, P. P., Alonso, A., Newman, A. B., Ives, D. G., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.03.529 · Cited by 239
Yao, Y., Chen, J., Guo, Y., Lv, T., Chen, Z., Li, N., Cao, S., Chen, B., & Chen, T. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113078 · Cited by 213
Dietary cholesterol: from physiology to cardiovascular risk
Lecerf, J.-M., & de Lorgeril, M. (2011) · British Journal of Nutrition · doi:10.1017/s0007114511000237 · Cited by 182
Liu, Y., Yu, Q., Luo, X., Yang, L., & Cui, Y. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00302-w · Cited by 182
Comparative Molecular Dynamics Study of Lipid Membranes Containing Cholesterol and Ergosterol
Czub, J., & Baginski, M. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.072801 · Cited by 170
Biocompatibility Considerations in the Design of Graphene Biomedical Materials
Bullock, C. J., & Bussy, C. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201900229 · Cited by 161
Hwang, H. J., Ryu, M. Y., Park, C. Y., Ahn, J. K., Park, H. G., Choi, C., Ha, S., Park, T. J., & Park, J. P. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.031 · Cited by 160
Lin, X., Ni, Y., & Serge Kokot, A. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.04.019 · Cited by 160
Saifullah, K. M., & Rad, Z. F. (2023) · Advanced Materials Interfaces · doi:10.1002/admi.202201763 · Cited by 148
Yang, B., Fang, X., & Kong, J. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000591 · Cited by 138
High-performance electrochemical biosensor for the detection of total cholesterol
Ahmadalinezhad, A., & Chen, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.011 · Cited by 128
Huang, Y. X., Tan, J., Cui, L., Zhou, Z., Zhou, S., Zhang, Z., Zheng, R., Xue, Y., Zhang, M., Li, S., et al. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.037 · Cited by 118
Recent Advances in Electrochemical and Optical Biosensors for Cancer Biomarker Detection
Son, M. H., Park, S. W., Sagong, H. Y., & Jung, Y. K. (2022) · BioChip Journal · doi:10.1007/s13206-022-00089-6 · Cited by 99
Cholesterol asymmetry in synaptic plasma membranes
Gibson Wood, W., Igbavboa, U., Müller, W. E., & Eckert, G. P. (2011) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2010.07017.x · Cited by 86
Recent Progress in Electrochemical Immunosensors
Kim, J. Y., & Park, M. (2021) · Biosensors · doi:10.3390/bios11100360 · Cited by 79
Self-citationMeasurement of Cholesterol: A Patient Perspective
Birtcher, K. K., & Ballantyne, C. M. (2004) · Circulation · doi:10.1161/01.cir.0000141564.89465.4e · Cited by 71
A responsive hydrogel-based microneedle system for minimally invasive glucose monitoring
Wang, Y., Liu, H., Yang, X., Shi, Z., Li, J., Xue, L., Liu, S., & Lei, Y. (2022) · Smart Materials in Medicine · doi:10.1016/j.smaim.2022.07.006 · Cited by 65
Why Is Very High Cholesterol Content Beneficial for the Eye Lens but Negative for Other Organs?
Widomska, J., & Subczynski, W. K. (2019) · Nutrients · doi:10.3390/nu11051083 · Cited by 49
High Cholesterol Disorders, Myocardial Infarction and Its Therapeutics
Upadhyay, R. K. (2023) · World Journal of Cardiovascular Diseases · doi:10.4236/wjcd.2023.138040 · Cited by 44
Lehner, B., Benz, D., Moshkalev, S. A., Meyer, A. S., Cotta, M. A., & Janissen, R. (2021) · ACS Applied Nano Materials · doi:10.1021/acsanm.1c01522 · Cited by 41
A highly sensitive biosensor based on Au NPs/rGO-PAMAM-Fc nanomaterials for detection of cholesterol
Zhu, J., Ye, Z., Fan, X., Wang, H., Wang, Z., & Chen, B. (2019) · International Journal of Nanomedicine · doi:10.2147/ijn.s184013 · Cited by 37
Biosensing Technologies for Chronic Diseases
Park, M., & Heo, Y. J. (2021) · BioChip Journal · doi:10.1007/s13206-021-00014-3 · Cited by 30
Self-citationElectrochemical biosensors for early detection of cancer
Choudhary, M., & Arora, K. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823424-2.00024-7 · Cited by 28
Non-invasive diagnosis and follow-up of non-alcoholic fatty liver disease
Boursier, J., Guillaume, M., Bouzbib, C., Lannes, A., Pais, R., Smatti, S., Cariou, B., Bureau, C., Ganne‐Carrié, N., Bourlière, M., et al. (2021) · Clinics and Research in Hepatology and Gastroenterology · doi:10.1016/j.clinre.2021.101769 · Cited by 26
Development of albumin monitoring system with hepatic hypoxia-on-a-chip
Kim, J. Y., Han, Y., Jeon, B. G., Nam, M. S., Kwon, S., Heo, Y. J., & Park, M. (2023) · Talanta · doi:10.1016/j.talanta.2023.124592 · Cited by 15
Self-citationZhang, K., Zhou, H., Hu, P., & Lü, Q. (2019) · RSC Advances · doi:10.1039/c9ra07082f · Cited by 14
Kim, M. Y., Choi, D., Park, T., Jose, J., Lee, K., & Park, M. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136272 · Cited by 6
Self-citationNantaphol, S., Chailapakul, O., & Siangproh, W. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.10.041
A disposable amperometric biosensor for determining total cholesterol in whole blood
Cheng, F. J., He, J., & Chen, Z. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.01.005
Optical sensing of pH using thin films of substituted polyanilines
Pringsheim, E., Terpetschnig, E., & Wolfbeis, O. S. (1997) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)00563-1
Research works printed but not linked: 6
- Ma, 2006, Cholesterol and human health, The Journal of American Science, 2, 46
- Friedel, 2023, Opportunities and challenges in the diagnostic utility of dermal interstitial fluid, Nat. Biomed. Eng., 1
- Jung, 2021, Microneedle for transdermal drug delivery: current trends and fabrication, Journal of pharmaceutical investigation, 1
- Rad, 2021, An overview of microneedle applications, materials, and fabrication methods, Beilstein J. Nanotechnol., 12, 1034
- Park, 2021, Biosensing technologies for chronic diseases, BioChip Journal, 1, 10.1007/s13206-021-00014-3 · DOI
- Tieu, 2023, Rapid and ultrasensitive detection of Staphylococcus aureus using a gold-interdigitated single-wave-shaped electrode (Au-ISWE) electrochemical biosensor, BioChip Journal, 1
Metadata
- Authors
- Kim, J., Kim, M. Y., Han, Y., Lee, G. Y., Kim, D. H., Heo, Y. J., & Park, M.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2024-12
- Volume
- 280
- Pages
- 126771
- ISSN
- 0039-9140
- Cited by
- 18
- References
- 36
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor)
- Funders
- National Research Foundation of Korea
- Ministry of Science, ICT and Future Planning (RS-2023-00207801, RS-2024-00410438, RS-2024-00354312)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.