Peri-procedural anticoagulation in patients undergoing ablation for atrial fibrillation
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Radiofrequency catheter ablation is being used with increasing frequency as a strategy to manage atrial fibrillation. Patients undergoing this procedure are at increased short-term risk of thromboembolism for several days and up to 4 weeks or longer after their ablation, and anticoagulation management surrounding the ablation procedure remains controversial. Although no conclusive recommendations can be made, published guidelines and data support therapeutic anticoagulation with warfarin for 3 weeks prior and intravenous heparin during the ablation. Warfarin may either be continued through the ablation or stopped 2–5 days prior. If the latter approach is chosen, a pre-ablation bridging strategy of enoxaparin 1 mg/kg twice daily is reasonable in selected patients unless the patient’s bleeding risk dictates using a lower dose regimen (0.5 mg/kg twice daily) or avoiding bridging altogether. Fewer data are available for post-ablation management strategies, and current practice patterns are based largely on single-center experiences in smaller, non-randomized studies. For lower risk patients (CHADS2 0–1), either warfarin or aspirin may be utilized without bridging. In higher thromboembolic risk patients (CHADS2 ≥ 2), either enoxaparin (1 mg/kg twice daily) or heparin may be started within the first 12–24 h post-procedure. For patients with bleeding risk factors, enoxaparin may be subsequently reduced to 0.5 mg/kg until the INR is therapeutic, although the efficacy of this lower dosing regimen has not been well studied. In accordance with national guidelines, warfarin should be continued post-ablation for a minimum of 2 months and then indefinitely in patients with a CHADS2 score ≥ 2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Gage, B. F., Yan, Y., Milligan, P. E., Waterman, A. D., Culverhouse, R., Rich, M. W., & Radford, M. J. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.04.017 · Cited by 1,008
Kearon, C., Ginsberg, J. S., Kovacs, M. J., Anderson, D. R., Wells, P., Julian, J. A., MacKinnon, B., Weitz, J. I., Crowther, M. A., Dolan, S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035422 · Cited by 751
Gage, B. F., van Walraven, C., Pearce, L., Hart, R. G., Koudstaal, P. J., Boode, B. S. P., & Petersen, P. (2004) · Circulation · doi:10.1161/01.cir.0000145172.55640.93 · Cited by 749 · cited 1×
“In AF patients with a CHADS2 score of 0-1 –where the risk of stroke may be lower – warfarin is more controversial, given its narrow therapeutic window and risk of major or life-threatening bleeding, and either warfarin or aspirin are recommended for chronic anticoagulation, according to patient and provider preference…”
Hindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H. (2005) · Circulation · doi:10.1161/circulationaha.104.518837 · Cited by 506 · cited 1×
“Based on the high rate of asymptomatic AF after ablation [48] as well as the increased failure rates in patients with long-standing AF and/or those who have undergone multiple procedures [32,35,46], the duration of anticoagulation should be based largely on a patient's TE risk factors (i.”
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Metadata
- Authors
- Vazquez, S. R., Johnson, S. A., & Rondina, M. T.
- Venue
- Thrombosis Research
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 126
- Issue
- 2
- Pages
- e69-e77
- ISSN
- 0049-3848 (ISSN-L)
- OpenAlex
- W1976787568
- Cited by
- 39
- References
- 5
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.