The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Cryo-Electron Microscopy Methodology: Current Aspects and Future Directions
Open accessAbstract
Cryo-electron microscopy (cryo-EM) has emerged as a powerful structure determination technique. Its most prolific branch is single particle analysis (SPA), a method being used in a growing number of laboratories worldwide to determine high-resolution protein structures. Cryo-electron tomography (cryo-ET) is another powerful approach that enables visualization of protein complexes in their native cellular environment. Despite the wide-ranging success of cryo-EM, there are many methodological aspects that could be improved. Those include sample preparation, sample screening, data acquisition, image processing, and structure validation. Future developments will increase the reliability and throughput of the technique and reduce the cost and skill level barrier for its adoption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kühlbrandt, W. (2014) · Science · doi:10.1126/science.1251652 · Cited by 1,325
Electron crystallography of ultrathin 3D protein crystals: atomic model with charges
Yonekura, K., Kato, K., Ogasawara, M., Tomita, M., & Toyoshima, C. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1500724112 · Cited by 190
Visual proteomics of the human pathogen Leptospira interrogans
Beck, M., Malmström, J. A., Lange, V., Schmidt, A., Deutsch, E. W., & Aebersold, R. (2009) · Nature Methods · doi:10.1038/nmeth.1390 · Cited by 156
Inner lumen proteins stabilize doublet microtubules in cilia and flagella
Owa, M., Uchihashi, T., Yanagisawa, H.-A., Yamano, T., Iguchi, H., Fukuzawa, H., Wakabayashi, K.-I., Ando, T., & Kikkawa, M. (2019) · Nature Communications · doi:10.1038/s41467-019-09051-x · Cited by 140
Self-citation
Cited by
Single-particle cryo-EM at atomic resolution
Nakane, T., Kotecha, A., Sente, A., McMullan, G., Masiulis, S., Brown, P. M. G. E., Grigoras, I. T., Malinauskaite, L., Malinauskas, T., Miehling, J., et al. (2020) · Nature · doi:10.1038/s41586-020-2829-0 · Cited by 868
Zivanov, J., Nakane, T., & Scheres, S. H. W. (2020) · IUCrJ · doi:10.1107/s2052252520000081 · Cited by 781
Multi-particle cryo-EM refinement with M visualizes ribosome-antibiotic complex at 3.5 Å in cells
Tegunov, D., Xue, L., Dienemann, C., Cramer, P., & Mahamid, J. (2021) · Nature Methods · doi:10.1038/s41592-020-01054-7 · Cited by 509
Cryo-EM single-particle structure refinement and map calculation using Servalcat
Yamashita, K., Palmer, C. M., Burnley, T., & Murshudov, G. N. (2021) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798321009475 · Cited by 333
Cryo-EM and artificial intelligence visualize endogenous protein community members
Skalidis, I., Kyrilis, F. L., Tüting, C., Hamdi, F., Chojnowski, G., & Kastritis, P. L. (2022) · Structure · doi:10.1016/j.str.2022.01.001 · Cited by 61
Metadata
- Authors
- Danev, R., Yanagisawa, H., & Kikkawa, M.
- Venue
- Trends in Biochemical Sciences
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 44
- Issue
- 10
- Pages
- 837-848
- ISSN
- 0968-0004 (ISSN-L)
- OpenAlex
- W2944108200
- Cited by
- 229
- References
- 4
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cryo-Electron Microscopy Methodology: Current Aspects and Future Directions. https://app.cochat.ai/papers/10.1016/j.tibs.2019.04.008
- The paper
- Danev, R., Yanagisawa, H., & Kikkawa, M. (2019). Cryo-Electron Microscopy Methodology: Current Aspects and Future Directions. Trends in Biochemical Sciences. https://doi.org/10.1016/j.tibs.2019.04.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.