The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Point-of-care technologies for molecular diagnostics using a drop of blood
Open accessAbstract
Molecular diagnostics is critical for prevention, identification, and treatment of disease. Traditional technologies for molecular diagnostics using blood are limited to laboratory use because they rely on sample purification and sophisticated instruments, are labor- and time-intensive and expensive, and require highly trained operators. This review discusses the frontiers of point-of-care diagnostic technologies using a drop of blood obtained from a finger-prick. These technologies, including emerging biotechnologies, nanotechnologies, and microfluidics, hold the potential for rapid, accurate, and inexpensive disease diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
High-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Microchip-based immunomagnetic detection of circulating tumor cells
Hoshino, K., Huang, Y.-Y., Lane, N., Huebschman, M., Uhr, J. W., Frenkel, E. P., & Zhang, X. (2011) · Lab on a Chip · doi:10.1039/c1lc20270g · Cited by 400
Self-citation
Cited by
Point-of-Care Diagnostics: Recent Developments in a Connected Age
Nayak, S., Blumenfeld, N. R., Laksanasopin, T., & Sia, S. K. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04630 · Cited by 508
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Point of care testing: The impact of nanotechnology
Syedmoradi, L., Daneshpour, M., Alvandipour, M., Gomez, F. A., Hajghassem, H., & Omidfar, K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.084 · Cited by 367
Stress Biomarkers in Biological Fluids and Their Point-of-Use Detection
Steckl, A. J., & Ray, P. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00726 · Cited by 319
Plasmon-Based Colorimetric Nanosensors for Ultrasensitive Molecular Diagnostics
Tang, L., & Li, J. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00282 · Cited by 299
Metadata
- Authors
- Song, Y., Huang, Y.-Y., Liu, X., Zhang, X., Ferrari, M., & Qin, L.
- Venue
- Trends in Biotechnology
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 32
- Issue
- 3
- Pages
- 132-139
- ISSN
- 0167-7799 (ISSN-L)
- OpenAlex
- W1989437429
- Cited by
- 228
- References
- 4
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Point-of-care technologies for molecular diagnostics using a drop of blood. https://app.cochat.ai/papers/10.1016/j.tibtech.2014.01.003
- The paper
- Song, Y., Huang, Y.-Y., Liu, X., Zhang, X., Ferrari, M., & Qin, L. (2014). Point-of-care technologies for molecular diagnostics using a drop of blood. Trends in Biotechnology. https://doi.org/10.1016/j.tibtech.2014.01.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.