The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Recent advances in potentiometric biosensors
Abstract
Abstract Potentiometry based on ion-selective electrodes (ISEs) has been injected with new vigor and gone through a renaissance with the improvements in the detection limits and selectivities of ISEs, the introduction of new materials, new sensing concepts (from conventional potentiometry to dynamic electrochemistry approaches), and deeper theoretical understanding and modelling of the potentiometric responses of ISEs. The new breakthroughs encourage innovations in ion sensing and biosensing applications. Moreover, with the introduction of new bioreceptors, such as enzymes, antibodies, aptamers, peptides, versatile sensing protocols have been designed for a broad range of different target molecules by using ISEs as powerful transducers. This paper reviews the recent trends in potentiometric biosensors. Their applications in biosensing of metal ions, small molecules, DNA, proteins, bacteria and toxicities have been discussed. This review provides the outlook of the potentiometric biosensing based on the integration of potentiometric ISEs with new materials and emerging techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“The integration of different kind of ISEs with wearable sensor arrays represents a next-generation platform for healthcare, diagnostics and environmental monitoring [59].”
BackgroundCarrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics
Bakker, E., Bühlmann, P., & Pretsch, E. (1997) · Chemical Reviews · doi:10.1021/cr940394a · Cited by 2,369
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
An integrated semiconductor device enabling non-optical genome sequencing
Rothberg, J. M., Hinz, W., Rearick, T. M., Schultz, J., Mileski, W., Davey, M., Leamon, J. H., Johnson, K., Milgrew, M. J., Edwards, M., et al. (2011) · Nature · doi:10.1038/nature10242 · Cited by 2,172
Bühlmann, P., Pretsch, E., & Bakker, E. (1998) · Chemical Reviews · doi:10.1021/cr970113+ · Cited by 1,859
Biosensors: sense and sensibility
Turner, A. P. F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35528d · Cited by 1,654
Bobacka, J., Ivaska, A., & Lewenstam, A. (2008) · Chemical Reviews · doi:10.1021/cr068100w · Cited by 975
Electrochemical Sensors and Biosensors
Kimmel, D. W., LeBlanc, G., Meschievitz, M. E., & Cliffel, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac202878q · Cited by 947
Aptamer in Bioanalytical Applications
Iliuk, A. B., Hu, L., & Tao, W. A. (2011) · Analytical Chemistry · doi:10.1021/ac201057w · Cited by 762
Rational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Metadata
- Authors
- Ding, J., & Qin, W.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 124
- Pages
- 115803
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2996893167
- Cited by
- 322
- References
- 75
- FWCI
- 20.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent advances in potentiometric biosensors. https://app.cochat.ai/papers/10.1016/j.trac.2019.115803
- The paper
- Ding, J., & Qin, W. (2020). Recent advances in potentiometric biosensors. TrAC Trends in Analytical Chemistry. https://doi.org/10.1016/j.trac.2019.115803
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.