The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Recent advances in potentiometric biosensors
Abstract
Abstract Potentiometry based on ion-selective electrodes (ISEs) has been injected with new vigor and gone through a renaissance with the improvements in the detection limits and selectivities of ISEs, the introduction of new materials, new sensing concepts (from conventional potentiometry to dynamic electrochemistry approaches), and deeper theoretical understanding and modelling of the potentiometric responses of ISEs. The new breakthroughs encourage innovations in ion sensing and biosensing applications. Moreover, with the introduction of new bioreceptors, such as enzymes, antibodies, aptamers, peptides, versatile sensing protocols have been designed for a broad range of different target molecules by using ISEs as powerful transducers. This paper reviews the recent trends in potentiometric biosensors. Their applications in biosensing of metal ions, small molecules, DNA, proteins, bacteria and toxicities have been discussed. This review provides the outlook of the potentiometric biosensing based on the integration of potentiometric ISEs with new materials and emerging techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“The integration of different kind of ISEs with wearable sensor arrays represents a next-generation platform for healthcare, diagnostics and environmental monitoring [59].”
BackgroundCarrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics
Bakker, E., Bühlmann, P., & Pretsch, E. (1997) · Chemical Reviews · doi:10.1021/cr940394a · Cited by 2,369
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
An integrated semiconductor device enabling non-optical genome sequencing
Rothberg, J. M., Hinz, W., Rearick, T. M., Schultz, J., Mileski, W., Davey, M., Leamon, J. H., Johnson, K., Milgrew, M. J., Edwards, M., et al. (2011) · Nature · doi:10.1038/nature10242 · Cited by 2,172
Bühlmann, P., Pretsch, E., & Bakker, E. (1998) · Chemical Reviews · doi:10.1021/cr970113+ · Cited by 1,859
Biosensors: sense and sensibility
Turner, A. P. F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35528d · Cited by 1,654
Bobacka, J., Ivaska, A., & Lewenstam, A. (2008) · Chemical Reviews · doi:10.1021/cr068100w · Cited by 975
Electrochemical Sensors and Biosensors
Kimmel, D. W., LeBlanc, G., Meschievitz, M. E., & Cliffel, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac202878q · Cited by 947
Aptamer in Bioanalytical Applications
Iliuk, A. B., Hu, L., & Tao, W. A. (2011) · Analytical Chemistry · doi:10.1021/ac201057w · Cited by 762
Rational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Recent advances in ZnO nanostructures and thin films for biosensor applications: Review
Arya, S. K., Saha, S., Ramirez-Vick, J. E., Gupta, V., Bhansali, S., & Singh, S. P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.048 · Cited by 579
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Simultaneous DNA amplification and detection using a pH-sensing semiconductor system
Toumazou, C., Shepherd, L. M., Reed, S. C., Chen, G. I., Patel, A., Garner, D. M., Wang, C.-J. A., Ou, C.-P., Amin-Desai, K., Athanasiou, P., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2520 · Cited by 356
Zdrachek, E., & Bakker, E. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04681 · Cited by 338
Bakker, E., & Pretsch, E. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200605068 · Cited by 336
Wearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes
Lindner, E., & Gyurcsányi, R. E. (2009) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-008-0608-1 · Cited by 320
Universal mobile electrochemical detector designed for use in resource-limited applications
Nemiroski, A., Christodouleas, D. C., Hennek, J. W., Kumar, A. A., Maxwell, E. J., Fernández-Abedul, M. T., & Whitesides, G. M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405679111 · Cited by 285
A Textile‐Based Stretchable Multi‐Ion Potentiometric Sensor
Parrilla, M., Cánovas, R., Jeerapan, I., Andrade, F. J., & Wang, J. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600092 · Cited by 269 · cited 1×
“By using the tattoo-based platform and tailor-made stretchable materials, Wang's group have designed a number of tattoo-based potentiometric ion-selective sensors and wearable multi-ion potentiometric sensor [58].”
MethodBereza-Malcolm, L. T., Mann, G., & Franks, A. E. (2015) · ACS Synthetic Biology · doi:10.1021/sb500286r · Cited by 219
Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection
Parrilla, M., Cuartero, M., Padrell Sánchez, S., Rajabi, M., Roxhed, N., Niklaus, F., & Crespo, G. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04877 · Cited by 209
Zelada-Guillén, G. A., Sebastián-Avila, J. L., Blondeau, P., Riu, J., & Rius, F. X. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.021 · Cited by 207
Applications of nanomaterials in potentiometric sensors
Yin, T., & Qin, W. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.009 · Cited by 206
Self-citationResponse Mechanism of Polymer Membrane-Based Potentiometric Polyion Sensors
Fu, B., Bakker, E., Yun, J. H., Yang, V. C., & Meyerhoff, M. E. (1994) · Analytical Chemistry · doi:10.1021/ac00086a009 · Cited by 170
Solid-state reference electrodes for potentiometric sensors
Guth, U., Gerlach, F., Decker, M., Oelßner, W., & Vonau, W. (2009) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-008-0574-7 · Cited by 164
Selection and analytical applications of aptamers binding microbial pathogens
Hamula, C. L. A., Zhang, H., Li, F., Wang, Z., Le, X. C., & Li, X. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.08.006 · Cited by 128
Lindner, E., & Pendley, B. D. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.11.022 · Cited by 119
Potentiometric Urea Biosensor Based on an Immobilised Fullerene-Urease Bio-Conjugate
Saeedfar, K., Heng, L. Y., Ling, T. L., et al. (2013) · Sensors · doi:10.3390/s131216851 · Cited by 115
Electrochemical L-Lactic Acid Sensor Based on Immobilized ZnO Nanorods with Lactate Oxidase
Ibupoto, Z. H., Ali, S. M. U., Khun, K., & Willander, M. (2012) · Sensors · doi:10.3390/s120302456 · Cited by 112
New Signal Readout Principle for Solid-Contact Ion-Selective Electrodes
Mattinen, U., Hupa, E., Yrjänä, V., & Bobacka, J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04800 · Cited by 112
Electroanalysis with Membrane Electrodes and Liquid–Liquid Interfaces
Bakker, E. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04034 · Cited by 110
Han, T., Mattinen, U., & Bobacka, J. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01649 · Cited by 102
Nanostructured materials in potentiometry
Düzgün, A., Zelada‐Guillén, G. A., Crespo, G. A., Macho, S., Riu, J., & Rius, F. X. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3974-3 · Cited by 97
Novel Ion‐to‐Electron Transduction Principle for Solid‐Contact ISEs
Hupa, E., Mattinen, U., & Bobacka, J. (2015) · Electroanalysis · doi:10.1002/elan.201400596 · Cited by 97
He, N., Papp, S., Lindfors, T., Höfler, L., Latonen, R., & Gyurcsányi, R. E. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04885 · Cited by 96
Malon, A., Vigassy, T., Bakker, E., & Pretsch, E. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0625780 · Cited by 94
Bakker, E., & Pretsch, E. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.04.007 · Cited by 92
Zou, X. U., Zhen, X. V., Cheong, J. H., & Bühlmann, P. (2014) · Analytical Chemistry · doi:10.1021/ac501625z · Cited by 90
Liang, R., Ding, J., Gao, S., & Qin, W. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201701892 · Cited by 86
Self-citationPapp, S., Bojtár, M., Gyurcsányi, R. E., & Lindfors, T. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01587 · Cited by 83
Ibupoto, Z. H., Jamal, N., Khun, K., & Willander, M. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.03.083 · Cited by 82
Electrogenerated Chemiluminescence for Potentiometric Sensors
Crespo, G. A., Mistlberger, G., & Bakker, E. (2011) · Journal of the American Chemical Society · doi:10.1021/ja210600k · Cited by 79
Biologically Coupled Gate Field-Effect Transistors Meet in Vitro Diagnostics
Sakata, T. (2019) · ACS Omega · doi:10.1021/acsomega.9b01629 · Cited by 79
Potentiometric Aptasensing of Listeria monocytogenes Using Protamine as an Indicator
Ding, J., Lei, J., Ma, X., Gong, J., & Qin, W. (2014) · Analytical Chemistry · doi:10.1021/ac502335g · Cited by 75
Self-citationDevelopment of an Electrochemical Metal-Ion Biosensor Using Self-Assembled Peptide Nanofibrils
Viguier, B., Zór, K., Kasotakis, E., et al. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am200149h · Cited by 74
Mattinen, U., & Bobacka, J. (2014) · Analytical Chemistry · doi:10.1021/ac501464s · Cited by 73
Polyurethane Ionophore-Based Thin Layer Membranes for Voltammetric Ion Activity Sensing
Cuartero, M., Crespo, G. A., & Bakker, E. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01085 · Cited by 72
Indirect Determination of Mercury Ion by Inhibition of a Glucose Biosensor Based on ZnO Nanorods
Chey, C. O., Ibupoto, Z. H., Khun, K., et al. (2012) · Sensors · doi:10.3390/s121115063 · Cited by 70
Cytotoxicity Study of Ionophore-Based Membranes: Toward On-Body and in Vivo Ion Sensing
Cánovas, R., Sánchez, S. P., Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01322 · Cited by 68
Jiang, X., Wang, P., Liang, R., & Qin, W. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00039 · Cited by 66
Self-citationA label-free electrical detection of exosomal microRNAs using microelectrode array
Goda, T., Masuno, K., Nishida, J., Kosaka, N., Ochiya, T., Matsumoto, A., & Miyahara, Y. (2012) · Chemical Communications · doi:10.1039/c2cc36111f · Cited by 63
Can Calibration-Free Sensors Be Realized?
Bakker, E. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00247 · Cited by 63
Lindner, E., Guziński, M., Khan, T. A., & Pendley, B. D. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01651 · Cited by 60
Kałuża, D., Jaworska, E., Mazur, M., Maksymiuk, K., & Michalska, A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01286 · Cited by 53
Proton-ELISA: Electrochemical immunoassay on a dual-gated ISFET array
Juang, D. S., Lin, C.-H., Huo, Y., Tang, C., Cheng, C.-R., Wu, H.-S., Huang, S.-F., Kalnitsky, A., & Lin, C.-C. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.012 · Cited by 51
Label-Free Potentiometry for Detecting DNA Hybridization Using Peptide Nucleic Acid and DNA Probes
Goda, T., Singi, A., Maeda, Y., Matsumoto, A., Torimura, M., Aoki, H., & Miyahara, Y. (2013) · Sensors · doi:10.3390/s130202267 · Cited by 49
Redox Buffer Capacity of Ion-Selective Electrode Solid Contacts Doped with Organometallic Complexes
Zhen, X. V., Rousseau, C. R., & Bühlmann, P. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02595 · Cited by 47
Zhao, G., Liang, R., Wang, F., Ding, J., & Qin, W. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.09.125 · Cited by 47
Self-citationJiang, T., Qi, L., & Qin, W. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03974 · Cited by 45
Self-citationLv, E., Ding, J., & Qin, W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03809 · Cited by 44
Self-citationElectrogenerated Chemiluminescence for Chronopotentiometric Sensors
Gao, W., Jeanneret, S., Yuan, D., Cherubini, T. J., Wang, L., Xie, X., & Bakker, E. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00787 · Cited by 41
Chemical Modification of Polymer Ion‐Selective Membrane Electrode Surfaces
Pawlak, M., & Bakker, E. (2014) · Electroanalysis · doi:10.1002/elan.201300449 · Cited by 39
Application of nanoparticles in the potentiometric ion selective electrodes
Kakhki, R. M. (2013) · Russian Journal of Electrochemistry · doi:10.1134/s1023193513050078 · Cited by 38
Electrochemically Switchable Polymeric Membrane Ion-Selective Electrodes
Zdrachek, E. A., & Bakker, E. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01282 · Cited by 38
ZnO Nanostructure-Based Intracellular Sensor
Asif, M. H., Danielsson, B. R. G., & Willander, M. (2015) · Sensors · doi:10.3390/s150511787 · Cited by 32
Development of Galactose Biosensor Based on Functionalized ZnO Nanorods with Galactose Oxidase
Khun, K., Ibupoto, Z. H., Nur, O., & Willander, M. (2012) · Journal of Sensors · doi:10.1155/2012/696247 · Cited by 31
Ding, J., Yu, N., Wang, X., & Qin, W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03522 · Cited by 29
Self-citationGoda, T., Higashi, D., Matsumoto, A., Hoshi, T., Sawaguchi, T., & Miyahara, Y. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.067 · Cited by 27
Analytical quality solid-state composite reference electrode manufactured by injection moulding
Granholm, K., Mousavi, Z., Sokalski, T., & Lewenstam, A. (2013) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-013-2294-x · Cited by 24
Al‐Ghobashy, M. A., Nadim, A. H., El‐Sayed, G. M., & Nebsen, M. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01315 · Cited by 23
All-solid-state electrochemical platform for potentiometric measurements
Mousavi, Z., Granholm, K., Sokalski, T., & Lewenstam, A. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.06.067 · Cited by 21
Toczyłowska‐Mamińska, R., Lewenstam, A., & Dołowy, K. (2013) · Analytical Chemistry · doi:10.1021/ac403808f · Cited by 16
Wang, X., & Qin, W. (2012) · Chemical Communications · doi:10.1039/c2cc31020a · Cited by 14
Self-citationA chronopotentiometric flow injection system for aptasensing of E. coli O157
Lei, J., Ding, J., & Qin, W. (2015) · Analytical Methods · doi:10.1039/c4ay02662d · Cited by 8
Self-citationKarakuş, E., Pekyardımcı, Ş., & Kiliç, E. (2013) · Applied Biochemistry and Microbiology · doi:10.1134/s0003683813020051 · Cited by 7
Cited by
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
A critical review on the use of potentiometric based biosensors for biomarkers detection
Karimi-Maleh, H., Orooji, Y., Karimi, F., Alizadeh, M., Baghayeri, M., Rouhi, J., Tajik, S., Beitollahi, H., Agarwal, S., Gupta, V. K., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113252 · Cited by 473
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Biosensor nanoengineering: Design, operation, and implementation for biomolecular analysis
Purohit, B., Vernekar, P. R., Shetti, N. P., & Chandra, P. (2020) · Sensors International · doi:10.1016/j.sintl.2020.100040 · Cited by 421
Recent advances in molecularly imprinted polymer-based electrochemical sensors
Li, Y., Luo, L., Kong, Y., Li, Y., Wang, Q., Wang, M., Li, Y., Davenport, A., & Li, B. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116018 · Cited by 308
Metadata
- Authors
- Ding, J., & Qin, W.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 124
- Pages
- 115803
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2996893167
- Cited by
- 322
- References
- 75
- FWCI
- 20.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.