The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Designs for a quantum electron microscope
Open accessAbstract
One of the astounding consequences of quantum mechanics is that it allows the detection of a target using an incident probe, with only a low probability of interaction of the probe and the target. This 'quantum weirdness' could be applied in the field of electron microscopy to generate images of beam-sensitive specimens with substantially reduced damage to the specimen. A reduction of beam-induced damage to specimens is especially of great importance if it can enable imaging of biological specimens with atomic resolution. Following a recent suggestion that interaction-free measurements are possible with electrons, we now analyze the difficulties of actually building an atomic resolution interaction-free electron microscope, or "quantum electron microscope". A quantum electron microscope would require a number of unique components not found in conventional transmission electron microscopes. These components include a coherent electron beam-splitter or two-state-coupler, and a resonator structure to allow each electron to interrogate the specimen multiple times, thus supporting high success probabilities for interaction-free detection of the specimen. Different system designs are presented here, which are based on four different choices of two-state-couplers: a thin crystal, a grating mirror, a standing light wave and an electro-dynamical pseudopotential. Challenges for the detailed electron optical design are identified as future directions for development. While it is concluded that it should be possible to build an atomic resolution quantum electron microscope, we have also identified a number of hurdles to the development of such a microscope and further theoretical investigations that will be required to enable a complete interpretation of the images produced by such a microscope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum dynamics of single trapped ions
Leibfried, D., Blatt, R., Monroe, C., & Wineland, D. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.281 · Cited by 2,739
The Zeno’s paradox in quantum theory
Misra, B., & Sudarshan, E. C. G. (1977) · Journal of Mathematical Physics · doi:10.1063/1.523304 · Cited by 2,722
Alushin, G. M., Lander, G. C., Kellogg, E. H., Zhang, R., Baker, D., & Nogales, E. (2014) · Cell · doi:10.1016/j.cell.2014.03.053 · Cited by 696
Quantum mechanical interaction-free measurements
Elitzur, A. C., & Vaidman, L. (1993) · Foundations of Physics · doi:10.1007/bf00736012 · Cited by 673
Interaction-free quantum measurements: A paradox?
Dicke, R. H. (1981) · American Journal of Physics · doi:10.1119/1.12592 · Cited by 231
Cited by
Metrology for the next generation of semiconductor devices
Orji, N. G., Badaroglu, M., Barnes, B. M., Beitia, C., Bunday, B. D., Celano, U., Kline, R. J., Neisser, M., Obeng, Y., & Vladar, A. E. (2018) · Nature Electronics · doi:10.1038/s41928-018-0150-9 · Cited by 501
Priebe, K. E., Rathje, C., Yalunin, S. V., Hohage, T., Feist, A., Schäfer, S., & Ropers, C. (2017) · Nature Photonics · doi:10.1038/s41566-017-0045-8 · Cited by 351
Electron-beam spectroscopy for nanophotonics
Polman, A., Kociak, M., & García de Abajo, F. J. (2019) · Nature Materials · doi:10.1038/s41563-019-0409-1 · Cited by 309
Frequency mixing property of electron cloud in a Penning trap at room temperature
Nandi, J., Sikdar, A. K., Das, P., & Ray, A. (2023) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2023.168647 · Cited by 4
Metadata
- Authors
- Kruit, P., Hobbs, R. G., Kim, C.-S., Yang, Y., Manfrinato, V. R., Hammer, J., Thomas, S., Weber, P., Klopfer, B., Kohstall, C., Juffmann, T., Kasevich, M. A., Hommelhoff, P., & Berggren, K. K.
- Venue
- Ultramicroscopy
- Publisher
- Elsevier BV
- Published
- 2016-05
- Volume
- 164
- Pages
- 31-45
- ISSN
- 0304-3991 (ISSN-L)
- OpenAlex
- W1784834300
- Cited by
- 160
- References
- 5
- FWCI
- 11.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Designs for a quantum electron microscope. https://app.cochat.ai/papers/10.1016/j.ultramic.2016.03.004
- The paper
- Kruit, P., Hobbs, R. G., Kim, C.-S., Yang, Y., Manfrinato, V. R., Hammer, J., Thomas, S., Weber, P., Klopfer, B., Kohstall, C., Juffmann, T., Kasevich, M. A., Hommelhoff, P., & Berggren, K. K. (2016). Designs for a quantum electron microscope. Ultramicroscopy. https://doi.org/10.1016/j.ultramic.2016.03.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.