Frequency mixing property of electron cloud in a Penning trap at room temperature
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The axial frequency of the stored electron cloud depends on the applied voltages between the ring and end-cap electrodes according to the given formula.
“The axial frequency ( ωz ) of the stored electron cloud depends on the applied voltages ( U0 = V R - V E ) between the ring and end-cap electrodes [1, 9, 42]:”
From Development and Characterization of a Cryogenic Tuned Amplifier for Penning Trap Applications (2025) · cites this paper as [42]
Cites
High-accuracy mass spectrometry with stored ions
Blaum, K. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.011 · Cited by 685 · see citing works
Ion-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413 · see citing works
Principles of the stored ion calorimeter
Wineland, D. J., & Dehmelt, H. G. (1975) · Journal of Applied Physics · doi:10.1063/1.321602 · Cited by 328 · see citing works
Open-endcap Penning traps for high precision experiments
Gabrielse, G., Haarsma, L., & Rolston, S. L. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85027-x · Cited by 288 · see citing works
Long-Time Containment of a Pure Electron Plasma
Malmberg, J. H., & Driscoll, C. F. (1980) · Physical Review Letters · doi:10.1103/physrevlett.44.654 · Cited by 193 · see citing works
Cylindrical Penning traps with orthogonalized anharmonicity compensation
Gabrielse, G., & Mackintosh, F. C. (1984) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(84)85061-2 · Cited by 167 · see citing works
Designs for a quantum electron microscope
Kruit, P., Hobbs, R. G., Kim, C.-S., Yang, Y., Manfrinato, V. R., Hammer, J., Thomas, S., Weber, P., Klopfer, B. B., Kohstall, C., et al. (2016) · Ultramicroscopy · doi:10.1016/j.ultramic.2016.03.004 · Cited by 161 · see citing works
Wineland, D. J., Ekstrom, P. A., & DEHMELT, H. G. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.1279 · Cited by 150 · see citing works
Observation of transport to thermal equilibrium in pure electron plasmas
Driscoll, C. F., Malmberg, J. H., & Fine, K. S. (1988) · Physical Review Letters · doi:10.1103/physrevlett.60.1290 · Cited by 123 · see citing works
A 16-parts-per-trillion measurement of the antiproton-to-proton charge–mass ratio
Borchert, M. J., Devlin, J. A., Erlewein, S., Fleck, M., Harrington, J. A., Higuchi, T., Latacz, B. M., Voelksen, F., Wursten, E., Abbass, F., et al. (2022) · Nature · doi:10.1038/s41586-021-04203-w · Cited by 84 · see citing works
Investigation of the fine structure of antihydrogen
Ahmadi, M., Alves, B. X. R., Baker, C. J., Bertsche, W. A., Capra, A., Carruth, C., Cesar, C. L., Charlton, M., Cohen, S., Collister, R., et al. (2020) · Nature · doi:10.1038/s41586-020-2006-5 · Cited by 76 · see citing works
The electron mass from g -factor measurements on hydrogen-like carbon 12 C 5+
Köhler, F., Sturm, S., Kracke, A., Werth, G., Quint, W., & Blaum, K. (2015) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/48/14/144032 · Cited by 70 · see citing works
Measurement of the bound-electron g-factor difference in coupled ions
Sailer, T., Debierre, V., Harman, Z., Heiße, F., König, C. M., Morgner, J., Tu, B., Volotka, A. V., Keitel, C. H., Blaum, K., et al. (2022) · Nature · doi:10.1038/s41586-022-04807-w · Cited by 66 · see citing works
Absolute measurement of the total number of ions stored in an RF quadrupole trap
Gaboriaud, M. N., Desaintfuscien, M., & Major, F. G. (1981) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(81)85022-x · Cited by 60 · see citing works
g Factor of Boronlike Argon Ar4013+
Arapoglou, I., Egl, A., Höcker, M., Sailer, T., Tu, B., Weigel, A., Wolf, R. N., Cakir, H., Yerokhin, V. A., Oreshkina, N. S., et al. (2019) · Physical Review Letters · doi:10.1103/physrevlett.122.253001 · Cited by 58 · see citing works
Extraction of the electron mass from g -factor measurements on light hydrogenlike ions
Zatorski, J., Sikora, B., Karshenboim, S. G., Sturm, S., Köhler-Langes, F., Blaum, K., Keitel, C. H., & Harman, Z. (2017) · Physical Review A · doi:10.1103/physreva.96.012502 · Cited by 51 · see citing works
g Factor of Lithiumlike Silicon: New Challenge to Bound-State QED
Glazov, D. A., Köhler-Langes, F., Volotka, A. V., Blaum, K., Heiße, F., Plunien, G., Quint, W., Rau, S., Шабаев, В. М., Sturm, S., et al. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.173001 · Cited by 43 · see citing works
Microwave Guiding of Electrons on a Chip
Hoffrogge, J., Fröhlich, R., Kasevich, M. A., & Hommelhoff, P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.193001 · Cited by 38 · see citing works
Electronic Detection of Collective Modes of an Ultracold Plasma
Twedt, K. A., & Rolston, S. L. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.065003 · Cited by 34 · see citing works
Trapping Electrons in a Room-Temperature Microwave Paul Trap
Matthiesen, C., Yu, Q., Guo, J., Alonso, A., & Häffner, H. (2021) · Physical Review X · doi:10.1103/physrevx.11.011019 · Cited by 33 · see citing works
Rischka, A., Cakir, H., Door, M., Filianin, P., Harman, Z., Huang, W. J., Indelicato, P., Keitel, C. H., König, C. M., Kromer, K., et al. (2020) · Physical Review Letters · doi:10.1103/physrevlett.124.113001 · Cited by 27 · see citing works
Resistive and sympathetic cooling of highly-charged-ion clouds in a Penning trap
Vogel, M., Häffner, H., Hermanspahn, K., Stahl, S., Steinmann, J., & Quint, W. (2014) · Physical Review A · doi:10.1103/physreva.90.043412 · Cited by 26 · see citing works
Trapping Electrons in a Room-Temperature Microwave Paul Trap
Matthiesen, C., Yu, Q., Guo, J., Alonso, A., & Häffner, H. (2021) · eScholarship (California Digital Library) · Cited by 24 · see citing works
Examining the N = 28 shell closure through high-precision mass measurements of Ar 46 – 48
Mougeot, M., Atanasov, D., Barbieri, C., Blaum, K., Breitenfeld, M., de Roubin, A., Duguet, T., George, S., Herfurth, F., Herlert, A., et al. (2020) · Physical Review C · doi:10.1103/physrevc.102.014301 · Cited by 19 · see citing works
Resistive cooling of highly charged ions in a Penning trap to a fluidlike state
Ebrahimi, M. S., Guo, Z. M., Vogel, M., Wiesel, M., Birkl, G., & Quint, W. (2018) · Physical Review A · doi:10.1103/physreva.98.023423 · Cited by 15 · see citing works
High-precision mass measurement of doubly magic $$^{208}$$Pb
Kromer, K., Lyu, C., Door, M., Filianin, P., Harman, Z., Herkenhoff, J., Huang, W. J., Keitel, C. H., Lange, D., Novikov, Y. N., et al. (2022) · The European Physical Journal A · doi:10.1140/epja/s10050-022-00860-1 · Cited by 13 · see citing works
Paasche, P., Valenzuela, T., Biswas, D., Angelescu, C., & Werth, G. (2002) · The European Physical Journal D · doi:10.1140/epjd/e20020033 · Cited by 13 · see citing works
Cooling and self-excitation of a one-electron oscillator
D’Urso, B. (2003) · Cited by 11 · see citing works
Fluid and kinetic nonlinearities of near-acoustic plasma waves
Affolter, M., Anderegg, F., Dubin, D. H. E., Valentini, F., & Driscoll, C. F. (2019) · Physics of Plasmas · doi:10.1063/1.5129529 · Cited by 8 · see citing works
Design of a dynamically orthogonalized Penning trap with higher order anharmonicity compensation
Sikdar, A. K., Ray, A., Das, P., & Reza, A. (2013) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2013.01.062 · Cited by 7 · see citing works
Self-citationDesign of a helical resonator with improved figure of merit
Nandi, J., Sikdar, A. K., Das, P., & Ray, A. (2022) · Review of Scientific Instruments · doi:10.1063/5.0065422 · Cited by 5 · see citing works
Self-citationPlasma Heating due to Cyclic Diffusion across a Separatrix
Anderegg, F., Affolter, M., Dubin, D. H. E., & Driscoll, C. F. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.105002 · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Zuo, Z., Xiao, X., Gao, M., & Rao, C. (2025) · Renewable Energy · doi:10.1016/j.renene.2025.123055 · Cited by 10 · see citing works
Temporal evolution of electron cloud in a cylindrical Penning trap at room temperature
Nandi, J., Sikdar, A. K., Kumar, A., Alam, S., Das, P., & Ray, A. (2024) · Review of Scientific Instruments · doi:10.1063/5.0194917 · Cited by 2 · see citing works
Self-citationDevelopment and Characterization of a Cryogenic Tuned Amplifier for Penning Trap Applications
Chaddha, N., Sikdar, A. K., Nandi, J., Vyshnav, C. H., Chatterjee, M., Das, P., & Ray, A. (2025) · Journal of Low Temperature Physics · doi:10.1007/s10909-025-03309-z
Self-citationQuality factor enhancement of detection electronics of Penning trap at cryogenic temperature
Nandi, J., Sikdar, A. K., Chaddha, N., Das, P., & Ray, A. (2024) · Indian Journal of Cryogenics · doi:10.5958/2349-2120.2024.00003.8
Self-citation
- Authors
- Nandi, J., Sikdar, A. K., Das, P., & Ray, A.
- Affiliations
- Variable Energy Cyclotron Centre (IN)
- Corresponding author
- Sikdar, A.K.
- Venue
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Publisher
- Elsevier BV
- Published
- 2023-11
- Volume
- 1056
- Pages
- 168647
- ISSN
- 0168-9002 (ISSN-L)
- OpenAlex
- W4386258496
- Cited by
- 4
- References
- 32
- Citations by year
- 2025: 2 · 2024: 2
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment (publishedVersion)
- Funders
- Science and Engineering Research Board (CRG/2020/003237)
- Department of Science and Technology
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Particle accelerators and beam dynamics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle Detector Development and Performance
- Keywords
- Penning trap, electron cloud, frequency mixing, direct feedthrough, resonant absorption, room temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review