Ultrasound in contemporary physiotherapy practice
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Review of Therapeutic Ultrasound: Biophysical Effects
Baker, K. G., Robertson, V. J., & Duck, F. A. (2001) · Physical Therapy · doi:10.1093/ptj/81.7.1351 · Cited by 636
(1965) · Annals of Internal Medicine · doi:10.7326/0003-4819-63-4-741_2 · Cited by 419
ter Haar, G. (1999) · European Journal of Ultrasound · doi:10.1016/s0929-8266(99)00013-0 · Cited by 327
Doan, N., Reher, P., Meghji, S., & Harris, M. (1999) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(99)90281-1 · Cited by 319
The effect of therapeutic ultrasound on calcium uptake in fibroblasts
Mortimer, A. J., & Dyson, M. (1988) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(88)90111-1 · Cited by 251 · cited 2×
“For example, the application of ultrasound induces the degranulation of mast cells, causing the release of arachidonic acid which itself is a precursor for the synthesis of prostaglandins and leukotreine – which act as inflammatory mediators [25,37,38].”
BackgroundElectrotherapy: Evidence-Based Practice
Kitchen, S. S. (2001) · Research Portal (King's College London) · Cited by 180
The role of electrotherapy in contemporary physiotherapy practice
Watson, T. (2000) · Manual Therapy · doi:10.1054/math.2000.0363 · Cited by 172 · cited 3×
“The best absorbing tissues in terms of clinical practice are those with high collagen content – ligament, tendon, fascia, joint capsule, scar tissue [3,20–23].”
BackgroundSelf-citationStonnington, H. H. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03330230079047 · Cited by 168
The biomechanical effects of low-intensity ultrasound on healing tendons
Enwemeka, C. S., Rodriguez, O., & Mendosa, S. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90044-d · Cited by 164 · cited 1×
“[49] demonstrated that low dose pulsed ultrasound increases protein synthesis and several research groups have demonstrated enhanced fibroplasia and collagen synthesis [46,50–54].”
BackgroundTherapeutic ultrasound for venous leg ulcers
Cullum, N. A., & Liu, Z. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001180.pub4 · Cited by 147
Cited by
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
A Review of Low-Intensity Pulsed Ultrasound for Therapeutic Applications
Jiang, X., Savchenko, O., Li, Y., Qi, S., Yang, T., Zhang, W., & Chen, J. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2889669 · Cited by 353
Orloff, L. A., Noel, J. E., Stack, B. C., Russell, M. D., Angelos, P., Baek, J. H., Brumund, K. T., Chiang, F., Cunnane, M. B., Davies, L., et al. (2022) · Head & Neck · doi:10.1002/hed.26960 · Cited by 315
Molecular self-assembly and patterning induced by sound waves. The case of gelation
Cravotto, G., & Cintas, P. (2009) · Chemical Society Reviews · doi:10.1039/b901840a · Cited by 265
Carpal Tunnel Syndrome. Part I: Effectiveness of Nonsurgical Treatments–A Systematic Review
Huisstede, B. M., Hoogvliet, P., Randsdorp, M. S., Glerum, S., van Middelkoop, M., & Koes, B. W. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.03.022 · Cited by 238
Ultrasound-responsive polymer-based drug delivery systems
Wei, P., Cornel, E. J., & Du, J. (2021) · Drug Delivery and Translational Research · doi:10.1007/s13346-021-00963-0 · Cited by 188
Clinical applications of low-intensity pulsed ultrasound and its potential role in urology
Xin, Z., Lin, G., Lei, H., Lue, T. F., & Guo, Y. (2016) · Translational Andrology and Urology · doi:10.21037/tau.2016.02.04 · Cited by 184
“As the energy within the sound wave is passed down into the tissues, it will cause oscillation of the particles (10).”
BackgroundInfluentialMoretti, F. A., Marcondes, F. B., Provenza, J. R., Fukuda, T. Y., de Vasconcelos, R. A., & Roizenblatt, S. (2012) · Physiotherapy Research International · doi:10.1002/pri.525 · Cited by 26
“Pulsed (ultrasound) US can promote tissue healing, favour microcirculation and vascular permeability, promote muscle relaxation (Srbely and Dickey, 2007), stimulate angiogenesis (Barzelai et al., 2006; Watson, 2008) and increase the metabolism and permeability of the cell membrane (Mortimer and Dyson, 1988), thereby j…”
Background
Metadata
- Authors
- Watson, T.
- Venue
- Ultrasonics
- Publisher
- Elsevier BV
- Published
- 2008-08
- Volume
- 48
- Issue
- 4
- Pages
- 321-329
- ISSN
- 0041-624X (ISSN-L)
- OpenAlex
- W2129753795
- Cited by
- 228
- References
- 29
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.