The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Mode & mechanism of low intensity pulsed ultrasound (LIPUS) in fracture repair
Open accessAbstract
It has been 30years since the first level one clinical trial demonstrated low intensity pulsed ultrasound (LIPUS) could accelerate fracture repair. Since 1994 numerous investigations have been performed on the effect of LIPUS. The majority of these studies have used the same signal parameters comprised of an intensity of 30mW/cm(2) SATA, an ultrasound carrier frequency of 1.5MHz, pulsed at 1kHz with an exposure time of 20minutes per day. These studies show that a biological response is stimulated in the cell which produces bioactive molecules. The production of these molecules, linked with observations demonstrating the enhanced effects on mineralization by LIPUS, might be considered the general manner, or mode, of how LIPUS stimulates fractures to heal. We propose a mechanism for how the LIPUS signal can enhance fracture repair by combining the findings of numerous studies. The LIPUS signal is transmitted through tissue to the bone, where cells translate this mechanical signal to a biochemical response via integrin mechano-receptors. The cells enhance the production of cyclo-oxygenese 2 (COX-2) which in turn stimulates molecules to enhance fracture repair. The aim of this review is to present the state of the art data related to LIPUS effects and mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anthropometric Reference Data for Children and Adults: United States, 2003-2006: (623932009-001)
McDowell, M. A., Fryar, C. D., Ogden, C. L., & Flegal, K. M. (2008) · PsycEXTRA Dataset · doi:10.1037/e623932009-001 · Cited by 1,378
Cited by
A Review of Low-Intensity Pulsed Ultrasound for Therapeutic Applications
Jiang, X., Savchenko, O., Li, Y., Qi, S., Yang, T., Zhang, W., & Chen, J. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2889669 · Cited by 353
Methods to accelerate fracture healing – a narrative review from a clinical perspective
Ganse, B. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1384783 · Cited by 33
Murakami, R., Sanada, T., Inagawa, M., Yoshitomi, H., Honda, E., Fukai, A., & Iwaso, H. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04611-z · Cited by 6
Metadata
- Authors
- Harrison, A., Lin, S., Pounder, N., & Mikuni-Takagaki, Y.
- Venue
- Ultrasonics
- Publisher
- Elsevier BV
- Published
- 2016-08
- Volume
- 70
- Pages
- 45-52
- ISSN
- 0041-624X (ISSN-L)
- OpenAlex
- W2325082853
- Cited by
- 194
- References
- 1
- FWCI
- 11.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mode & mechanism of low intensity pulsed ultrasound (LIPUS) in fracture repair. https://app.cochat.ai/papers/10.1016/j.ultras.2016.03.016
- The paper
- Harrison, A., Lin, S., Pounder, N., & Mikuni-Takagaki, Y. (2016). Mode & mechanism of low intensity pulsed ultrasound (LIPUS) in fracture repair. Ultrasonics. https://doi.org/10.1016/j.ultras.2016.03.016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.