Abstract
It has been 30years since the first level one clinical trial demonstrated low intensity pulsed ultrasound (LIPUS) could accelerate fracture repair. Since 1994 numerous investigations have been performed on the effect of LIPUS. The majority of these studies have used the same signal parameters comprised of an intensity of 30mW/cm(2) SATA, an ultrasound carrier frequency of 1.5MHz, pulsed at 1kHz with an exposure time of 20minutes per day. These studies show that a biological response is stimulated in the cell which produces bioactive molecules. The production of these molecules, linked with observations demonstrating the enhanced effects on mineralization by LIPUS, might be considered the general manner, or mode, of how LIPUS stimulates fractures to heal. We propose a mechanism for how the LIPUS signal can enhance fracture repair by combining the findings of numerous studies. The LIPUS signal is transmitted through tissue to the bone, where cells translate this mechanical signal to a biochemical response via integrin mechano-receptors. The cells enhance the production of cyclo-oxygenese 2 (COX-2) which in turn stimulates molecules to enhance fracture repair. The aim of this review is to present the state of the art data related to LIPUS effects and mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Oxford English Dictionary and Its Philosophy
Simpson, J. (2013) · Philosophy & Technology · doi:10.1007/s13347-013-0118-7 · Cited by 2,064
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Anthropometric Reference Data for Children and Adults: United States, 2003-2006: (623932009-001)
McDowell, M. A., Fryar, C. D., Ogden, C. L., & Flegal, K. M. (2008) · PsycEXTRA Dataset · doi:10.1037/e623932009-001 · Cited by 1,378
Sensing and reacting to microbes through the inflammasomes
Franchi, L., Muñoz-Planillo, R., & Núñez, G. (2012) · Nature Immunology · doi:10.1038/ni.2231 · Cited by 1,012
Acceleration of tibial fracture-healing by non-invasive, low-intensity pulsed ultrasound.
Heckman, J. D., Ryaby, J. P., McCabe, J., Frey, J. J., & Kilcoyne, R. F. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199401000-00004 · Cited by 956
Musculoskeletal Conditions in the United States
Praemer, A., Furner, S. E., & Rice, D. P. (1992) · Medical Entomology and Zoology · Cited by 930
Production of a standard closed fracture in laboratory animal bone
Bonnarens, F., & Einhorn, T. A. (1984) · Journal of Orthopaedic Research · doi:10.1002/jor.1100020115 · Cited by 888
KRISTIANSEN, T. K., RYABY, J. P., McCABE, J., FREY, J. J., & ROE, L. R. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199707000-00002 · Cited by 586
Cyclo-Oxygenase 2 Function Is Essential for Bone Fracture Healing
Simon, A. M., Manigrasso, M. B., & O'Connor, J. P. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.6.963 · Cited by 530
Giannoudis, P. V., MacDonald, D. A., Matthews, S. J., Smith, R. M., Furlong, A. J., & De Boer, P. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b5.0820655 · Cited by 411
Inhibition of fracture healing
Gaston, M. S., & Simpson, A. H. R. W. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b12.19671 · Cited by 380
Azuma, Y., Ito, M., Harada, Y., Takagi, H., Ohta, T., & Jingushi, S. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.4.671 · Cited by 369
Ehrbar, M., Djonov, V. G., Schnell, C., Tschanz, S. A., Martiny-Baron, G., Schenk, U., Wood, J., Burri, P. H., Hubbell, J. A., & Zisch, A. H. (2004) · Circulation Research · doi:10.1161/01.res.0000126411.29641.08 · Cited by 357
Low intensity ultrasound treatment increases strength in a rat femoral fracture model
Wang, S., Lewallen, D. G., Bolander, M. E., Chao, E. Y. S., Ilstrup, D. M., & Greenleaf, J. F. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120106 · Cited by 323
Assessment of Compromised Fracture Healing
Bishop, J. A., Palanca, A. A., Bellino, M. J., & Lowenberg, D. W. (2012) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/jaaos-20-05-273 · Cited by 304
Low-Intensity Pulsed Ultrasound in the Treatment of Nonunions
Nolte, P. A., van der Krans, A., Patka, P., Janssen, I. M. C., Ryaby, J. P., & Albers, G. H. R. (2001) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200110000-00012 · Cited by 302
Otsuru, S., Tamai, K., Yamazaki, T., Yoshikawa, H., & Kaneda, Y. (2008) · Stem Cells · doi:10.1634/stemcells.2007-0515 · Cited by 275
Molecular Mechanisms of Low Intensity Pulsed Ultrasound in Human Skin Fibroblasts
Zhou, S., Schmelz, A., Seufferlein, T., Li, Y., Zhao, J., & Bachem, M. G. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m404786200 · Cited by 270
Stimulation of bone repair with ultrasound: A review of the possible mechanic effects
Padilla, F., Puts, R., Vico, L., & Raum, K. (2014) · Ultrasonics · doi:10.1016/j.ultras.2014.01.004 · Cited by 234
Nicotine on the Revascularization of Bone Graft: An Experimental Study in Rabbits
Daftari, T. K., Whitesides, T. E., Heller, J. G., Goodrich, A. C., McCarey, B. E., & Hutton, W. C. (1994) · Spine · doi:10.1097/00007632-199404150-00007 · Cited by 218
Ultrasound stimulates nitric oxide and prostaglandin e 2 production by human osteoblasts
Reher, P., Harris, M., Whiteman, M., Hai, H. K., & Meghji, S. (2002) · Bone · doi:10.1016/s8756-3282(02)00789-5 · Cited by 192
The economics of treating tibia fractures. The cost of delayed unions.
Jd, H., & Sarasohn-Kahn, J. (1997) · PubMed · Cited by 185
Tang, C.-H., Yang, R.-S., Huang, T.-H., Lu, D.-Y., Chuang, W.-J., Huang, T.-F., & Fu, W.-M. (2006) · Molecular Pharmacology · doi:10.1124/mol.105.022160 · Cited by 180
Distinct Anabolic Response of Osteoblast to Low-Intensity Pulsed Ultrasound
Naruse, K., Miyauchi, A., Itoman, M., & Mikuni-Takagaki, Y. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.2.360 · Cited by 173
Self-citationPounder, N. M., & Harrison, A. J. (2008) · Ultrasonics · doi:10.1016/j.ultras.2008.02.005 · Cited by 170
Self-citationReduced COX-2 Expression in Aged Mice Is Associated With Impaired Fracture Healing
Naik, A. A., Xie, C., Zuscik, M. J., Kingsley, P., Schwarz, E. M., Awad, H., Guldberg, R., Drissi, H., Puzas, J. E., Boyce, B., et al. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081002 · Cited by 161
Angle, S. R., Sena, K., Sumner, D. R., & Virdi, A. S. (2010) · Ultrasonics · doi:10.1016/j.ultras.2010.09.004 · Cited by 155
Schofer, M. D., Block, J. E., Aigner, J., & Schmelz, A. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-229 · Cited by 128
Watabe, H., Furuhama, T., Tani‐Ishii, N., & Mikuni‐Takagaki, Y. (2011) · Experimental Cell Research · doi:10.1016/j.yexcr.2011.07.015 · Cited by 126
Self-citationDiabetes, Diabetic Complications, and Fracture Risk
Oei, L., Rivadeneira, F., Zillikens, M. C., & Oei, E. H. G. (2015) · Current Osteoporosis Reports · doi:10.1007/s11914-015-0260-5 · Cited by 125
Bandow, K., Nishikawa, Y., Ohnishi, T., Kakimoto, K., Soejima, K., Iwabuchi, S., Kuroe, K., & Matsuguchi, T. (2006) · Journal of Cellular Physiology · doi:10.1002/jcp.20944 · Cited by 120
Wei, F., Leung, K., Li, G., Qin, J., Chow, S. K., Huang, S., Sun, M.-H., Qin, L., & Cheung, W. (2014) · PLoS ONE · doi:10.1371/journal.pone.0106722 · Cited by 107
Pulsed Low Intensity Ultrasound Enhances Mineralisation in Preosteoblast Cells
Unsworth, J., Kaneez, S., Harris, S., Ridgway, J. N., Fenwick, S., Chenery, D. H., & Harrison, A. J. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.12.003 · Cited by 82
Self-citationLong-term follow-up of fracture nonunions treated with PEMFs.
Garland, D. E., Moses, B., & Salyer, W. A. (1991) · PubMed · Cited by 81
Suzuki, A., Takayama, T., Suzuki, N., Kojima, T., Ota, N., Asano, S., & Ito, K. (2009) · Journal of Oral Science · doi:10.2334/josnusd.51.29 · Cited by 69
Kumagai, K., Takeuchi, R., Ishikawa, H. T., Yamaguchi, Y., Fujisawa, T., Kuniya, T., Takagawa, S., Muschler, G. F., & Saito, T. (2012) · Journal of Orthopaedic Research® · doi:10.1002/jor.22103 · Cited by 60
Involvement of adenosine 5′-triphosphate in ultrasound-induced fracture repair
Hayton, M. J., Dillon, J. P., Glynn, D., Curran, J. M., Gallagher, J. A., & Buckley, K. M. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.04.017 · Cited by 55
Naruse, K., Sekiya, H., Harada, Y., Iwabuchi, S., Kozai, Y., Kawamata, R., Kashima, I., Uchida, K., Urabe, K., Seto, K., et al. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.04.011 · Cited by 55
Self-citationThe effects of low‐intensity pulsed ultrasound upon diabetic fracture healing
Coords, M., Breitbart, E. A., Paglia, D. N., Kappy, N. S., Gandhi, A., Cottrell, J. A., Cedeno, N., Pounder, N. M., O'Connor, J. P., & Lin, S. S. (2010) · Journal of Orthopaedic Research® · doi:10.1002/jor.21223 · Cited by 55
Self-citationTherapeutic Ultrasound Bypasses Canonical Syndecan-4 Signaling to Activate Rac1
Mahoney, C. M., Morgan, M. R., Harrison, A. J., Humphries, M. J., & Bass, M. D. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m804281200 · Cited by 48
Self-citationHasegawa, T., Miwa, M., Sakai, Y., Niikura, T., Kurosaka, M., & Komori, T. (2009) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.91b2.20827 · Cited by 41
SDF-1:CXCR4 Axis Is Fundamental for Tissue Preservation and Repair
Penn, M. S. (2010) · American Journal Of Pathology · doi:10.2353/ajpath.2010.100803 · Cited by 39
Leung, K., Lee, W.-S., Cheung, W., & Qin, L. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000137557.59228.4d · Cited by 26
Alterations of fracture healing in the diabetic condition.
Kagel, E. M., & Einhorn, T. A. (1996) · PubMed Central · Cited by 24
Saini, V., Yadav, S., & McCormick, S. M. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0156-6 · Cited by 21
Specification of acoustic output level and measurement uncertainty in ultrasonic exposimetry
Ziskin, M. C. (2003) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1226546 · Cited by 21
Cited by
A Review of Low-Intensity Pulsed Ultrasound for Therapeutic Applications
Jiang, X., Savchenko, O., Li, Y., Qi, S., Yang, T., Zhang, W., & Chen, J. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2889669 · Cited by 353
Methods to accelerate fracture healing – a narrative review from a clinical perspective
Ganse, B. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1384783 · Cited by 33
Murakami, R., Sanada, T., Inagawa, M., Yoshitomi, H., Honda, E., Fukai, A., & Iwaso, H. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04611-z · Cited by 6
Metadata
- Authors
- Harrison, A., Lin, S., Pounder, N., & Mikuni-Takagaki, Y.
- Venue
- Ultrasonics
- Publisher
- Elsevier BV
- Published
- 2016-08
- Volume
- 70
- Pages
- 45-52
- ISSN
- 0041-624X (ISSN-L)
- OpenAlex
- W2325082853
- Cited by
- 194
- References
- 46
- FWCI
- 11.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.