Delay-and-sum (DAS) is the most widespread digital beamformer in high-frame-rate ultrasound imaging. Its implementation is simple and compatible with real-time applications. In this viewpoint article, we describe the fundamentals of DAS beamforming. The underlying theory and numerical approach are detailed so that users can be aware of its functioning and limitations. In particular, we discuss the importance of the f-number and speed of sound on image quality, and propose one solution to set their values from a physical viewpoint. We suggest determining the f-number from the directivity of the transducer elements and the speed of sound from the phase dispersion of the delayed signals. Simplified Matlab codes are provided for the sake of clarity and openness. The effect of the f-number and speed of sound on the lateral resolution and contrast-to-noise ratio was investigated in vitro and in vivo. If not properly preset, these two factors had a substantial negative impact on standard metrics of image quality (namely CNR and FWHM). When beamforming with DAS in vitro or in vivo, it is recommended to optimize these parameters in order to use it wisely and prevent image degradation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814
Diagnostic Ultrasound Imaging: Inside Out
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07261-7 · Cited by 1,093
Diagnostic ultrasound Imaging : Inside out
(2005) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-2005-861725 · Cited by 761
Adaptive Beamforming Applied to Medical Ultrasound Imaging
Synnevag, J. F., Austeng, A., & Holm, S. (2007) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.431 · Cited by 592
Sparse Matrices in MATLAB: Design and Implementation
Gilbert, J. R., Moler, C., & Schreiber, R. (1992) · SIAM Journal on Matrix Analysis and Applications · doi:10.1137/0613024 · Cited by 591
Camacho, J., Parrilla, M., & Fritsch, C. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1128 · Cited by 525
Banerjee, M., Cui, X., Li, Z., Yu, H., Cai, L., Jia, X., He, D., Wang, C., Gao, T., & Xie, Z. (2018) · Scientific Reports · doi:10.1038/s41598-018-29995-2 · Cited by 506
Destrempes, F., & Cloutier, G. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.04.001 · Cited by 196
Principles of Digital Image Processing: Core Algorithms
Burger, W., & Burge, M. J. (2009) · Undergraduate Topics in Computer Science · doi:10.1007/978-1-84800-195-4 · Cited by 191
Deep Neural Networks for Ultrasound Beamforming
Luchies, A. C., & Byram, B. C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2809641 · Cited by 182
Robust sound speed estimation for ultrasound-based hepatic steatosis assessment
Imbault, M., Faccinetto, A., Osmanski, B.-F., Tissier, A., Deffieux, T., Gennisson, J.-L., Vilgrain, V., & Tanter, M. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6226 · Cited by 181
High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation
Poree, J., Posada, D., Hodzic, A., Tournoux, F., Cloutier, G., & Garcia, D. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2523346 · Cited by 160
Self-citationExperimental study of high frame rate imaging with limited diffraction beams
Lu, J.-Y. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.646914 · Cited by 159
Kyriakou, A., Neufeld, E., Werner, B., Paulides, M. M., Székely, G. J., & Kuster, N. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.861519 · Cited by 155
Ultrasound Open Platforms for Next-Generation Imaging Technique Development
Boni, E., Yu, A. C. H., Freear, S., Jensen, J. A., & Tortoli, P. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2844560 · Cited by 154
High-Quality Plane Wave Compounding Using Convolutional Neural Networks
Gasse, M., Millioz, F., Roux, E., Garcia, D., Liebgott, H., & Friboulet, D. (2017) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2017.2736890 · Cited by 130
Self-citationLeast-Squares Multi-Angle Doppler Estimators for Plane-Wave Vector Flow Imaging
Yiu, B. Y. S., & Yu, A. C. H. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2582514 · Cited by 124
Sound speed correction in ultrasound imaging
Napolitano, D., Chou, C.-H., McLaughlin, G. W., Ji, T.-L., Mo, L., DeBusschere, D., & Steins, R. (2006) · Ultrasonics · doi:10.1016/j.ultras.2006.06.061 · Cited by 115
2017 IEEE International Ultrasonics Symposium (IUS)
(2017) · doi:10.1109/ius36762.2017 · Cited by 110
Sanabria, S. J., Özkan, E., Rominger, M. B., et al. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aae2fb · Cited by 105
Yu, J., Lavery, L., & Kim, K. (2018) · Scientific Reports · doi:10.1038/s41598-018-32235-2 · Cited by 98
Principles of an experimental large aperture seismic array (LASA)
Green, P. E., Jr., Frosch, R. A., & Romney, C. F. (1965) · Proceedings of the IEEE · doi:10.1109/proc.1965.4453 · Cited by 88
Preissner, M., Murrie, R. P., Pinar, I. P., Werdiger, F., Carnibella, R. P., Zosky, G. R., Fouras, A., & Dubsky, S. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aab8d2 · Cited by 76
A Dual Tissue-Doppler Optical-Flow Method for Speckle Tracking Echocardiography at High Frame Rate
Porée, J., Baudet, M., Tournoux, F., Cloutier, G., & Garcia, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2811483 · Cited by 46
Self-citationMeshfree simulations of ultrasound vector flow imaging using smoothed particle hydrodynamics
Shahriari, S., & Garcia, D. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aae3c3 · Cited by 43
Self-citationColor and Vector Flow Imaging in Parallel Ultrasound With Sub-Nyquist Sampling
Madiena, C., Faurie, J., Porée, J., et al. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2817885 · Cited by 37
Analytical modeling of the instantaneous maximal transvalvular pressure gradient in aortic stenosis
Garcia, D., Kadem, L., Savéry, D., Pîbarot, P., & Durand, L. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.10.013 · Cited by 29
Self-citationHandbook of Speckle Filtering and Tracking in Cardiovascular Ultrasound Imaging and Video
(2018) · Institution of Engineering and Technology eBooks · doi:10.1049/pbhe013e · Cited by 26
Optimization techniques for sparse matrix–vector multiplication on GPUs
Maggioni, M., & Berger-Wolf, T. Y. (2016) · Journal of Parallel and Distributed Computing · doi:10.1016/j.jpdc.2016.03.011 · Cited by 25
Zubajlo, R. E., Benjamin, A., Grajo, J. R., Kaliannan, K., Kang, J. X., Bhan, A. K., Thomenius, K. E., Anthony, B., Dhyani, M., & Samir, A. E. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.07.020 · Cited by 24
Cited by
A survey on deep learning in medical ultrasound imaging
Song, K., Feng, J., & Chen, D. (2024) · Frontiers in Physics · doi:10.3389/fphy.2024.1398393 · Cited by 59
Metadata
- Authors
- Perrot, V., Polichetti, M., Varray, F., & Garcia, D.
- Venue
- Ultrasonics
- Publisher
- Elsevier BV
- Published
- 2021-03
- Volume
- 111
- Pages
- 106309
- ISSN
- 0041-624X (ISSN-L)
- OpenAlex
- W3044863663
- Cited by
- 377
- References
- 30
- FWCI
- 15.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.