CoChat

High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation

Poree, Jonathan, Posada, Daniel, Hodzic, Amir, Tournoux, Francois, Cloutier, Guy, Garcia, Damien · 2016 · IEEE Transactions on Medical Imaging
Cited by 160

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

High-frame-rate ultrasonography based on coherent compounding of unfocused beams can potentially transform the assessment of cardiac function. As it requires successive waves to be combined coherently, this approach is sensitive to high-velocity tissue motion. We investigated coherent compounding of tilted diverging waves, emitted from a 2.5 MHz clinical phased array transducer. To cope with high myocardial velocities, a triangle transmit sequence of diverging waves is proposed, combined with tissue Doppler imaging to perform motion compensation (MoCo). The compound sequence with integrated MoCo was adjusted from simulations and was tested in vitro and in vivo. Realistic myocardial velocities were analyzed in an in vitro spinning disk with anechoic cysts. While a 8 dB decrease (no motion versus high motion) was observed without MoCo, the contrast-to-noise ratio of the cysts was preserved with the MoCo approach. With this method, we could provide high-quality in vivo B-mode cardiac images with tissue Doppler at 250 frames per second. Although the septum and the anterior mitral leaflet were poorly apparent without MoCo, they became well perceptible and well contrasted with MoCo. The septal and lateral mitral annulus velocities determined by tissue Doppler were concordant with those measured by pulsed-wave Doppler with a clinical scanner (r(2)=0.7,y=0.9 x+0.5,N=60) . To conclude, high-contrast echo cardiographic B-mode and tissue Doppler images can be obtained with diverging beams when motion compensation is integrated in the coherent compounding process.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2016.2523346

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 160

Metadata

Authors
Poree, J., Posada, D., Hodzic, A., Tournoux, F., Cloutier, G., & Garcia, D.
Venue
IEEE Transactions on Medical Imaging
Published
2016-07
Volume
35
Issue
7
Pages
1647-1657
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2344293268
Cited by
160
References
24
FWCI
17.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation. https://app.cochat.ai/papers/10.1109/tmi.2016.2523346
The paper
Poree, J., Posada, D., Hodzic, A., Tournoux, F., Cloutier, G., & Garcia, D. (2016). High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2016.2523346

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.