The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Adaptive Beamforming Applied to Medical Ultrasound Imaging
Abstract
We have applied the minimum variance (MV) adaptive beamformer to medical ultrasound imaging and shown significant improvement in image quality compared to delay-and-sum (DAS). We demonstrate reduced mainlobe width and suppression of sidelobes on both simulated and experimental RF data of closely spaced wire targets, which gives potential contrast and resolution enhancement in medical images. The method is applied to experimental RF data from a heart phantom, in which we show increased resolution and improved definition of the ventricular walls. A potential weakness of adaptive beamformers is sensitivity to errors in the assumed wavefield parameters. We look at two ways to increase robustness of the proposed method; spatial smoothing and diagonal loading. We show that both are controlled by a single parameter that can move the performance from that of a MV beamformer to that of a DAS beamformer. We evaluate the sensitivity to velocity errors and show that reliable amplitude estimates are achieved while the mainlobe width and sidelobe levels are still significantly lower than for the conventional beamformer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-resolution frequency-wavenumber spectrum analysis
Capon, J. (1969) · Proceedings of the IEEE · doi:10.1109/proc.1969.7278 · Cited by 6,374
Introduction to Spectral Analysis
(2005) · Technometrics · doi:10.1198/tech.2005.s841 · Cited by 1,933
Boone, K. G., & Holder, D. S. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520003 · Cited by 1,919
On spatial smoothing for direction-of-arrival estimation of coherent signals
Shan, T.-J., Wax, M., & Kailath, T. (1985) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1985.1164649 · Cited by 1,894
On robust Capon beamforming and diagonal loading
Li, J., Stoica, P., & Wang, Z. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2003.812831 · Cited by 1,439
Introduction To Spectral Analysis
(2008) · Springer Texts in Statistics · doi:10.1007/978-0-387-75959-3_13 · Cited by 559
Time-delay- and time-reversal-based robust capon beamformers for ultrasound imaging
Wang, Z., Li, J., & Wu, R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.857222 · Cited by 195
Focusing filters for wide-band direction finding
Sivanand, S., Yang, J., & Kaveh, M. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.80827 · Cited by 29
Cited by
A survey on deep learning in medical ultrasound imaging
Song, K., Feng, J., & Chen, D. (2024) · Frontiers in Physics · doi:10.3389/fphy.2024.1398393 · Cited by 59
Metadata
- Authors
- Synnevag, J. F., Austeng, A., & Holm, S.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2007-08
- Volume
- 54
- Issue
- 8
- Pages
- 1606-1613
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2167589082
- Cited by
- 592
- References
- 8
- FWCI
- 10.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive Beamforming Applied to Medical Ultrasound Imaging. https://app.cochat.ai/papers/10.1109/tuffc.2007.431
- The paper
- Synnevag, J. F., Austeng, A., & Holm, S. (2007). Adaptive Beamforming Applied to Medical Ultrasound Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/tuffc.2007.431
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.