Noninvasive Thrombolysis Using Pulsed Ultrasound Cavitation Therapy – Histotripsy
Open accessAbstract
Clinically available thrombolysis techniques are limited by either slow reperfusion (drugs) or invasiveness (catheters), and carry significant risks of bleeding. In this study, the feasibility of using histotripsy as an efficient and non-invasive thrombolysis technique was investigated. Histotripsy fractionates soft tissue through controlled cavitation using focused, short, high-intensity ultrasound pulses. In-vitro blood clots formed from fresh canine blood were treated by histotripsy. The treatment was applied using a focused 1-MHz transducer, with 5-cycle pulses at a pulse repetition rate of 1 kHz. Acoustic pressures varying from 2 – 12 MPa peak negative pressure were tested. Our results show that histotripsy can perform effective thrombolysis with ultrasound energy alone. Histotripsy thrombolysis only occurred at peak negative pressure ≥6 MPa when initiation of a cavitating bubble cloud was detected using acoustic backscatter monitoring. Blood clots weighing 330 mg were completely broken down by histotripsy in 1.5 – 5 minutes. The clot was fractionated to debris with >96% weight smaller than 5 μm diameter. Histotripsy thrombolysis treatment remained effective under a fast, pulsating flow (a circulatory model) as well as in static saline. Additionally, we observed that fluid flow generated by a cavitation cloud can attract, trap, and further break down clot fragments. This phenomenon may provide a non-invasive method to filter and eliminate hazardous emboli during thrombolysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robbins pathologic basis of disease
Cotran, R. S., Kumar, V., & Collins, T. (1989) · Medical Entomology and Zoology · Cited by 1,944
Mewissen, M. W., Seabrook, G. R., Meissner, M. H., Cynamon, J., Labropoulos, N., & Haughton, S. H. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap4739 · Cited by 905
Robbins Pathologic Basis of Disease
Morrison, A. B. (1999) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.282.18.1776-a · Cited by 668
Kyrle, P. A., & Eichinger, S. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71880-8 · Cited by 616
Roberts, W. W., Hall, T. L., Ives, K., Wolf, J. S., Fowlkes, J. B., & Cain, C. A. (2006) · Journal of Urology · doi:10.1016/s0022-5347(05)00141-2 · Cited by 362
Self-citationBjarnason, H., Kruse, J. R., Asinger, D. A., Nazarian, G. K., Dietz, C. A., Caldwell, M. D., Key, N. S., Hirsch, A. T., & Hunter, D. W. (1997) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(97)70581-5 · Cited by 320
Treatment of Deep-Vein Thrombosis
Bates, S. M., & Ginsberg, J. S. (2004) · New England Journal of Medicine · doi:10.1056/nejmcp031676 · Cited by 265
Yu, X., Song, S.-K., Chen, J., Scott, M. J., Fuhrhop, R. J., Hall, C. S., Gaffney, P. J., Wickline, S. A., & Lanza, G. M. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200012)44:6<867::aid-mrm7>3.0.co;2-p · Cited by 238
In vivo whole-field blood velocity measurement techniques
Vennemann, P., Lindken, R., & Westerweel, J. (2007) · Experiments in Fluids · doi:10.1007/s00348-007-0276-4 · Cited by 173
Ultrasound Imaging–Guided Noninvasive Ultrasound Thrombolysis
Rosenschein, U., Furman, V., Kerner, E., Fabian, I., Bernheim, J., & Eshel, Y. (2000) · Circulation · doi:10.1161/01.cir.102.2.238 · Cited by 150
Cited by
Histotripsy: the first noninvasive, non-ionizing, non-thermal ablation technique based on ultrasound
Xu, Z., Hall, T. L., Vlaisavljevich, E., & Lee, F. T. (2021) · International Journal of Hyperthermia · doi:10.1080/02656736.2021.1905189 · Cited by 371
Self-citationUltrasound-Responsive Cavitation Nuclei for Therapy and Drug Delivery
Kooiman, K., Roovers, S., Langeveld, S. A. G., Kleven, R. T., Dewitte, H., O'Reilly, M. A., Escoffre, J.-M., Bouakaz, A., Verweij, M. D., Hynynen, K., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.01.002 · Cited by 359
Histotripsy methods in mechanical disintegration of tissue: Towards clinical applications
Khokhlova, V. A., Fowlkes, J. B., Roberts, W. W., Schade, G. R., Xu, Z., Khokhlova, T. D., Hall, T. L., Maxwell, A. D., Wang, Y.-N., & Cain, C. A. (2015) · International Journal of Hyperthermia · doi:10.3109/02656736.2015.1007538 · Cited by 317
Self-citationHigh intensity focused ultrasound: The fundamentals, clinical applications and research trends
Elhelf, I. A. S., Albahar, H., Shah, U., Oto, A., Cressman, E., & Almekkawy, M. (2018) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2018.03.001 · Cited by 264
Activating Drugs with Sound: Mechanisms Behind Sonodynamic Therapy and the Role of Nanomedicine
Choi, V., Rajora, M. A., & Zheng, G. (2020) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.0c00029 · Cited by 237
Metadata
- Authors
- Maxwell, A. D., Cain, C. A., Duryea, A. P., Yuan, L., Gurm, H. S., & Xu, Z.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2009-12
- Volume
- 35
- Issue
- 12
- Pages
- 1982-1994
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W1988392804
- Cited by
- 252
- References
- 20
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Thrombolysis Using Pulsed Ultrasound Cavitation Therapy – Histotripsy. https://app.cochat.ai/papers/10.1016/j.ultrasmedbio.2009.07.001
- The paper
- Maxwell, A. D., Cain, C. A., Duryea, A. P., Yuan, L., Gurm, H. S., & Xu, Z. (2009). Noninvasive Thrombolysis Using Pulsed Ultrasound Cavitation Therapy – Histotripsy. Ultrasound in Medicine & Biology. https://doi.org/10.1016/j.ultrasmedbio.2009.07.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.