Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 362

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Pulsed Cavitational Ultrasound: A Noninvasive Technology for Controlled Tissue Ablation (Histotripsy) in the Rabbit Kidney

Roberts, William W., Hall, Timothy L., Ives, Kimberly, Wolf, J. Stuart, Fowlkes, J. Brian, Cain, Charles A.·2006·Journal of Urology

Abstract

PURPOSE: The optimal minimally invasive treatment for small renal masses continues to evolve. Current ablative technologies rely on thermal mechanisms for tissue destruction. However, the creation of precise lesions is limited by inhomogeneous heating/cooling due to tissue variability, perfusion effects and tissue charring. We hypothesized that nonthermal mechanical effects of ultrasound (cavitation) can be used to progressively homogenize tissue in controlled fashion with predictable results. MATERIALS AND METHODS: We developed a focused annular array ultrasound system capable of delivering high intensity (greater than 20 kW/cm) short pulses (20 microseconds) of energy to a target volume. This system operates at a repetition frequency of 100 Hz, resulting in a low time averaged power output (approximately 5 W total acoustic output). Following approval from the institutional animal care committee a series of transcutaneous ablations were performed in the normal kidneys of 10 rabbits. RESULTS: Lesions created with a small number of pulses (10 or 100) produced scattered areas of damage characterized by focal hemorrhage and small areas of cellular injury in the targeted volume. Lesions created with greater numbers of pulses (1,000 or 10,000) demonstrated complete destruction of the targeted volume. Gross examination revealed that lesions contained a liquefied core with smooth walls and sharply demarcated boundaries. Histological examination demonstrated extensive areas of acellular debris surrounded by a narrow margin of cellular injury. CONCLUSIONS: This pulsed cavitational ultrasound system is capable of transcutaneous nonthermal destruction of renal tissue. Refinement of this technology for noninvasive ablation of small renal masses is currently under way.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-5347(05)00141-2

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 362

Metadata

Authors
Roberts, W. W., Hall, T. L., Ives, K., Wolf, J. S., Fowlkes, J. B., & Cain, C. A.
Venue
Journal of Urology
Published
2006-02
Volume
175
Issue
2
Pages
734-738
ISSN
  • 0022-5347 (ISSN-L)
  • 1527-3792
OpenAlex
W1983395182
Cited by
362
References
10
FWCI
10.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulsed Cavitational Ultrasound: A Noninvasive Technology for Controlled Tissue Ablation (Histotripsy) in the Rabbit Kidney. https://app.cochat.ai/papers/10.1016/s0022-5347(05)00141-2
The paper
Roberts, W. W., Hall, T. L., Ives, K., Wolf, J. S., Fowlkes, J. B., & Cain, C. A. (2006). Pulsed Cavitational Ultrasound: A Noninvasive Technology for Controlled Tissue Ablation (Histotripsy) in the Rabbit Kidney. Journal of Urology. https://doi.org/10.1016/s0022-5347(05)00141-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.