Effects of Ultrasound Frequency and Tissue Stiffness on the Histotripsy Intrinsic Threshold for Cavitation
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Previous work has demonstrated a cavitation cloud can be formed by a single pulse with one high amplitude negative cycle, when the negative pressure amplitude directly exceeds a pressure threshold intrinsic to the medium. We hypothesize that the intrinsic threshold in water-based tissues is determined by the properties of the water inside the tissue and changes in tissue stiffness or ultrasound frequency will have a minimal impact on the histotripsy intrinsic threshold. To test this hypothesis, the histotripsy intrinsic threshold was investigated both experimentally and theoretically. The probability of cavitation was measured by subjecting tissue phantoms with adjustable mechanical properties and ex vivo tissues to a histotripsy pulse of 1–2 cycles produced by 345 kHz, 500 kHz, 1.5 MHz, and 3 MHz histotripsy transducers. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured vs. pressure amplitude. The results demonstrated that the intrinsic threshold (the negative pressure at which probability=0.5) is independent of stiffness for Young’s moduli (E) < 1 MPa with only a small increase (~2–3 MPa) in the intrinsic threshold for tendon (E=380 MPa). Additionally, results for all samples showed only a small increase of ~2–3 MPa when the frequency was increased from 345 kHz to 3 MHz. The intrinsic threshold was measured to be between 24.7–30.6 MPa for all samples and frequencies tested in this study. Overall, the results of this study indicate that the intrinsic threshold to initiate a histotripsy bubble cloud is not significantly impacted by tissue stiffness or ultrasound frequency in hundreds of kHz to MHz range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leighton, T. G. (2012) · Cited by 2,284
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Bubble oscillations of large amplitude
Keller, J. B., & Miksis, M. (1980) · The Journal of the Acoustical Society of America · doi:10.1121/1.384720 · Cited by 1,346
Confidence interval estimation of interaction
Hosmer, D. W., & Lemeshow, S. (1992) · Epidemiology · doi:10.1097/00001648-199209000-00012 · Cited by 1,239 · cited 1×
“The standard errors for pint were estimated by a covariance matrix using the delta method (Hosmer and Lemeshow 1992).”
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Documenta Geigy; scientific tables.
(1963) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1963.03700140139041 · Cited by 778
The composition of body tissues
Woodard, H. Q., & White, D. R. (1986) · The British Journal of Radiology · doi:10.1259/0007-1285-59-708-1209 · Cited by 764 · cited 2×
“…a tissue mechanical property metric for this study and are provided in Table 1 (Diem and Lentner 1970; Duck 1990; International Commission on Radiological Protection [ICRP] 1975; International Commission on Radiological Units [ICRU] 1989; Staubli et al. 1999; Woodard and White 1986; Yamada 1973).”
Fisher, J. C. (1948) · Journal of Applied Physics · doi:10.1063/1.1698012 · Cited by 537 · cited 2×
“…a is the surface energy, kb is Boltzmann’s constant, T is temperature in Kelvin, G0 is a pre-factor, Vf is the focal volume for a given frequency and tf is the time the focal volume is above a given pressure (Arvengas et al. 2011a, 2011b; Fisher 1948; Herbert et al. 2006; Pettersen et al. 1994).”
Agarose gel stiffness determines rate of DRG neurite extension in 3D cultures
Balgude, A. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00350-1 · Cited by 518 · cited 1×
“The mechanical properties of the agarose phantoms were measured using a parallel-plate AR-G2 rheometer (TA Instruments, New Castle, DE, USA) on a Peltier stage, similar to previous studies (Balgude et al. 2001; Ulrich et al. 2010).”
Caupin, F., & Herbert, E. (2006) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2006.10.015 · Cited by 471 · cited 2×
“…methods have measured approximately the same threshold for inertial cavitation associated with these nuclei in the range 24 to 33 MPa in distilled water (Briggs 1950; Caupin and Herbert 2006; Greenspan and Tschiegg 1982; Herbert et al. 2006; Maxwell et al. 2013; Sankin and Teslenko 2003).”
Cited by
Histotripsy: the first noninvasive, non-ionizing, non-thermal ablation technique based on ultrasound
Xu, Z., Hall, T. L., Vlaisavljevich, E., & Lee, F. T. (2021) · International Journal of Hyperthermia · doi:10.1080/02656736.2021.1905189 · Cited by 371
Self-citation
Metadata
- Authors
- Vlaisavljevich, E., Lin, K.-W., Maxwell, A., Warnez, M. T., Mancia, L., Singh, R., Putnam, A. J., Fowlkes, B., Johnsen, E., Cain, C., & Xu, Z.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 41
- Issue
- 6
- Pages
- 1651-1667
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W2028549018
- Cited by
- 184
- References
- 25
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Ultrasound Frequency and Tissue Stiffness on the Histotripsy Intrinsic Threshold for Cavitation. https://app.cochat.ai/papers/10.1016/j.ultrasmedbio.2015.01.028
- The paper
- Vlaisavljevich, E., Lin, K.-W., Maxwell, A., Warnez, M. T., Mancia, L., Singh, R., Putnam, A. J., Fowlkes, B., Johnsen, E., Cain, C., & Xu, Z. (2015). Effects of Ultrasound Frequency and Tissue Stiffness on the Histotripsy Intrinsic Threshold for Cavitation. Ultrasound in Medicine & Biology. https://doi.org/10.1016/j.ultrasmedbio.2015.01.028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.