Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Training Midwives to Perform Basic Obstetric Point-of-Care Ultrasound in Rural Areas Using a Tablet Platform and Mobile Phone Transmission Technology—A WFUMB COE Project

Open access

Abstract

Point-of-care ultrasound (POCUS) has become a topical subject and can be applied in a variety of ways with differing outcomes. The cost of all diagnostic procedures including obstetric ultrasound examinations is a major factor in the developing world and POCUS is only useful if it can be equated to good outcomes at a lower cost than a routine obstetric examination. The aim of this study was to assess a number of processes including accuracy of images and reports generated by midwives, performance of a tablet-sized ultrasound scanner, training of midwives to complete ultrasounds, teleradiology solution transmissions of images via internet, review of images by a radiologist, communication between midwife and radiologist, use of this technique to identify high-risk patients and improvement of the education and teleradiology model components. The midwives had no previous experience in ultrasound. They were stationed in rural locations where POCUS was available for the first time. After scanning the patients, an interim report was generated by the midwives and sent electronically together with all images to the main hospital for validation. Unique software was used to send lossless images by mobile phone using a modem. Transmission times were short and quality of images transmitted was excellent. All reports were validated by two experienced radiologists in our department and returned to the centers using the same transmission software. The transmission times, quality of scans, quality of reports and other parameters were recorded and monitored. Analysis showed excellent correlation between provisional and validated reports. Reporting accuracy of scans performed by the midwives was 99.63%. Overall flow turnaround time (from patient presentation to validated report) was initially 35 min but reduced to 25 min. The unique mobile phone transmission was faultless and there was no degradation of image quality. We found excellent correlation between final outcomes of the pregnancies and diagnoses on the basis of reports generated by the midwives. Only 1 discrepancy was found in the midwives' reports. Scan results versus actual outcomes revealed 2 discrepancies in the 20 patients identified as high risk. In conclusion, we found that it is valuable to train midwives in POCUS to use an ultrasound tablet device and transmit images and reports via the internet to radiologists for review of accuracy. This focus on the identification of high-risk patients can be valuable in a remote healthcare facility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultrasmedbio.2017.05.024

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 VISIQ ultrasound machine with transducer (Philips Ultrasound, Inc., Bothell, WA).
Fig. 1 VISIQ ultrasound machine with transducer (Philips Ultrasound, Inc., Bothell, WA).CC-BY-NC-ND · From the PDF
Fig. 2 Study process.
Fig. 2 Study process.CC-BY-NC-ND · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 127

Metadata

Authors
Vinayak, S., Sande, J., Nisenbaum, H., & Nolsøe, C. P.
Affiliations
  • Aga Khan University Hospital Nairobi (KE)
  • Penn Presbyterian Medical Center (US)
  • University of Copenhagen (DK)
Corresponding author
Vinayak, Sudhir
Venue
Ultrasound in Medicine & Biology
Publisher
Elsevier BV
Published
2017-10
Volume
43
Issue
10
Pages
2125-2132
ISSN
0301-5629 (ISSN-L)
OpenAlex
W2735074909
Cited by
123
References
15
Citations by year
2026: 5 · 2025: 10 · 2024: 39 · 2023: 11 · 2022: 19 · 2021: 15 · 2020: 7 · 2019: 9 · 2018: 7
FWCI
5.98
Type
journal article
Language
en
Open access
Licence
Locations
  • Ultrasound in Medicine & Biology (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, cc-by-nc-nd)
  • eCommons - AKU (Aga Khan University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
point-of-care ultrasound, midwifery education, rural health care, teleradiology, high-risk pregnancy identification, telemedicine, developing countries
MeSH terms
Female, Humans, Kenya, Midwifery, Pilot Projects, Pregnancy, Ultrasonography, Point-of-Care Systems, Cell Phone, Rural Nursing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Training Midwives to Perform Basic Obstetric Point-of-Care Ultrasound in Rural Areas Using a Tablet Platform and Mobile Phone Transmission Technology—A WFUMB COE Project. https://app.cochat.ai/papers/10.1016/j.ultrasmedbio.2017.05.024
The paper
Vinayak, S., Sande, J., Nisenbaum, H., & Nolsøe, C. P. (2017). Training Midwives to Perform Basic Obstetric Point-of-Care Ultrasound in Rural Areas Using a Tablet Platform and Mobile Phone Transmission Technology—A WFUMB COE Project. Ultrasound in Medicine & Biology. https://doi.org/10.1016/j.ultrasmedbio.2017.05.024

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.