CoChat

Extraction of olive oil assisted by high-frequency ultrasound standing waves

Open access
Juliano, Pablo, Bainczyk, Fabian, Swiergon, Piotr, Supriyatna, Made Ian Maheswara, Guillaume, Claudia, Ravetti, Leandro, Canamasas, Pablo, Cravotto, Giancarlo, Xu, Xin-Qing · 2017 · Ultrasonics Sonochemistry
Cited by 87

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

High-frequency ultrasound standing waves (megasonics) have been demonstrated to enhance oil separation in the palm oil process at an industrial level. This work investigated the application of megasonics in the olive oil process on laboratory and pilot scale levels. Sound pressure level and cavitational yield distribution were characterised with hydrophones and luminol to determine associated physical and sonochemical effects inside the reactor. The effect of water addition (0%, 15%, and 30%), megasonic power levels (0%, 50%, and 100%), and malaxation time (10min, 30min, and 50min) was evaluated using response surface methodology (RSM) in a 700g batch extraction process. The RSM showed that the effect of the megasonic treatment (585kHz) in the presence of a reflector is more prominent at longer malaxation time (50min) and at higher water addition (30%) levels post-malaxation. Longer megasonic treatment of the malaxed paste (up to 15min; 220kJ/kg) increased oil extractability by up to 3.2%. When treating the malaxed paste with the same specific energy, higher oil extractability was obtained with longer treatments and low megasonic power levels in comparison to higher power levels and shorter times. Megasonic treatment of the paste before malaxation (585kHz, 10min, 146kJ/kg) and no water addition provided an increase in oil extractability of up to 3.8% with respect to the non-sonicated control. A double sonication intervention, before and after malaxation, using low (40kHz) and high (585kHz) frequency, respectively, provided up to 2.4% increase in oil extractability. A megasonic intervention post-malaxation (400 and 600kHz, 57-67min, 18-21kJ/kg) on a pilot scale using early-harvest olive fruits resulted in up to 1.7% extra oil extractability. Oil extracted under a high sonication frequency (free radical production regime) did not impact on olive oil quality parameters at reactor characterisation levels. Megasonic standing wave forces can enhance olive oil separation at various stages of the olive oil extraction process.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultsonch.2017.02.038

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 87

Metadata

Authors
Juliano, P., Bainczyk, F., Swiergon, P., Supriyatna, M. I. M., Guillaume, C., Ravetti, L., Canamasas, P., Cravotto, G., & Xu, X.-Q.
Venue
Ultrasonics Sonochemistry
Publisher
Elsevier BV
Published
2017-09
Volume
38
Pages
104-114
ISSN
1350-4177 (ISSN-L)
OpenAlex
W2592080967
Cited by
87
References
2
FWCI
3.95
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Extraction of olive oil assisted by high-frequency ultrasound standing waves. https://app.cochat.ai/papers/10.1016/j.ultsonch.2017.02.038
The paper
Juliano, P., Bainczyk, F., Swiergon, P., Supriyatna, M. I. M., Guillaume, C., Ravetti, L., Canamasas, P., Cravotto, G., & Xu, X.-Q. (2017). Extraction of olive oil assisted by high-frequency ultrasound standing waves. Ultrasonics Sonochemistry. https://doi.org/10.1016/j.ultsonch.2017.02.038

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.