An evaluation of fixation methods: Spatial and compositional cellular changes observed by Raman imaging
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Although live cell imaging is desirable, it is not always feasible and in many situations cells are fixed in order to provide a ‘snapshot’ of the nature and distribution of molecules within a cell while minimising changes from cell movement, sample degradation etc. There is a wide range of fixation methods available that act via different mechanisms, and on different cell components. Each method has advantages and disadvantages and a choice of what fixation method to choose for a particular experiment needs to take these factors into consideration. Here we used Raman spectroscopic imaging of live cells, and compared with cells preserved with aldehyde, or organic solvent-based fixation methods to assess the chemical changes induced by each fixative, and their impact on the quality of images that can be obtained from fixed cells. Overall, aldehyde fixation methods performed significantly better than organic solvents with less severe loss of biochemical information. Aldehyde based fixatives show an altered biochemical content of the cells, attributed to adduct formation, but this can be minimised by optimising fixation temperature, or through removal of adduct formation by detergent-based permeabilization treatments as a second step (at the cost of the loss of other biochemical information). The results showed that organic solvents, on the other hand, lead to a severe loss of cell content, attributed to the loss of membrane integrity after the removal of lipids. Additionally, fixation with aldehydes prior to permeabilization with organic solvents does not provide adequate protection of cytoplasmic content. The use of Raman imaging is ideal for comparing groups of cells in terms of their molecular content, and the results show that aldehyde fixations methods are preferable for studies where the overall molecular content of the samples is important. Although there is no universal fixation method for every application, the results here allow us to provide a few general principles: where spectral similarity to live cells is important, fixation with paraformaldehyde at room temperature is preferable, at the cost of some blebbing and vacuole formation. Where preservation of cellular structure or biomolecular distribution is important, a mix of paraformaldehyde and glutaraldehyde would be more appropriate, but at the cost of some changes to spectral profile, particularly in DNA-related bands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reference database of Raman spectra of biological molecules
De Gelder, J., De Gussem, K., Vandenabeele, P., & Moens, L. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1734 · Cited by 1,425
Effect of Fixatives and Tissue Processing on the Content and Integrity of Nucleic Acids
Srinivasan, M., Sedmak, D., & Jewell, S. (2002) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64472-0 · Cited by 1,318
Fox, C. H., Johnson, F. B., Whiting, J., & Roller, P. P. (1985) · Journal of Histochemistry & Cytochemistry · doi:10.1177/33.8.3894502 · Cited by 1,087
Identification of Formaldehyde-induced Modifications in Proteins
Metz, B., Kersten, G. F. A., Hoogerhout, P., Brugghe, H. F., Timmermans, H. A. M., de Jong, A., Meiring, H., ten Hove, J., Hennink, W. E., Crommelin, D. J. A., et al. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m310752200 · Cited by 610
Chemical and physical basics of routine formaldehyde fixation
Thavarajah, R., Mudimbaimannar, V. K., Elizabeth, J., Rao, U. K., & Ranganathan, K. (2012) · Journal of Oral and Maxillofacial Pathology · doi:10.4103/0973-029x.102496 · Cited by 509
Formaldehyde, Formalin, Paraformaldehyde And Glutaraldehyde: What They Are And What They Do
Kiernan, J. A. (2000) · Microscopy Today · doi:10.1017/s1551929500057060 · Cited by 505
Evaluation of Non-Formalin Tissue Fixation for Molecular Profiling Studies
Gillespie, J. W., Best, C. J. M., Bichsel, V. E., Cole, K. A., Greenhut, S. F., Hewitt, S. M., Ahram, M., Gathright, Y. B., Merino, M. J., Strausberg, R. L., et al. (2002) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64864-x · Cited by 284
Permeabilization of Cell Membranes
Jamur, M. C., & Oliver, C. (2010) · Methods in Molecular Biology · doi:10.1007/978-1-59745-324-0_9 · Cited by 280
SnapShot: Timescales in Cell Biology
Shamir, M., Bar-On, Y., Phillips, R., & Milo, R. (2016) · Cell · doi:10.1016/j.cell.2016.02.058 · Cited by 257
Mason, J. T., & O'Leary, T. J. (1991) · Journal of Histochemistry & Cytochemistry · doi:10.1177/39.2.1987266 · Cited by 246
Cited by
The role of platelets in mediating a response to human influenza infection
Koupenova, M., Corkrey, H. A., Vitseva, O., Manni, G., Pang, C. J., Clancy, L., Yao, C., Rade, J., Levy, D., Wang, J. P., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09607-x · Cited by 275
Karlupia, N., Schalek, R. L., Wu, Y., Meirovitch, Y., Wei, D., Charney, A. W., Kopell, B. H., & Lichtman, J. W. (2023) · Biological Psychiatry · doi:10.1016/j.biopsych.2023.01.025 · Cited by 33
Metadata
- Authors
- Hobro, A. J., & Smith, N. I.
- Venue
- Vibrational Spectroscopy
- Publisher
- Elsevier BV
- Published
- 2017-07
- Volume
- 91
- Pages
- 31-45
- ISSN
- 0924-2031 (ISSN-L)
- OpenAlex
- W2539651361
- Cited by
- 194
- References
- 22
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.