The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Advances in on-line drinking water quality monitoring and early warning systems
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence as a potential monitoring tool for recycled water systems: A review
Henderson, R. K., Baker, A., Murphy, K. R., Hambly, A., Stuetz, R. M., & Khan, S. J. (2009) · Water Research · doi:10.1016/j.watres.2008.11.027 · Cited by 990
Molecular biology of bacterial bioluminescence
Meighen, E. A. (1991) · Microbiological Reviews · doi:10.1128/mmbr.55.1.123-142.1991 · Cited by 796
Krantz-Rülcker, C., Stenberg, M., Winquist, F., & Lundström, I. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)00873-4 · Cited by 277
Xie, C., Mace, J., Dinno, M. A., Li, Y. Q., Tang, W., Newton, R. J., & Gemperline, P. J. (2005) · Analytical Chemistry · doi:10.1021/ac0504971 · Cited by 233
Liang, J. L., Dziuban, E. J., Craun, G. F., Hill, V. R., Moore, M. R., Gelting, R. J., Calderon, R. L., Beach, M. J., & Roy, S. L. (2006) · PubMed · Cited by 231
Effects and Interactions in an Environmentally Relevant Mixture of Pharmaceuticals
Pomati, F., Orlandi, C., Clerici, M., Luciani, F., & Zuccato, E. (2008) · Toxicological Sciences · doi:10.1093/toxsci/kfm291 · Cited by 218
Detection of bacteria by surface-enhanced Raman spectroscopy
Sengupta, A., Mujacic, M., & Davis, E. J. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0711-z · Cited by 188
Carotenoid Analysis of Halophilic Archaea by Resonance Raman Spectroscopy
Marshall, C. P., Leuko, S., Coyle, C. M., Walter, M. R., Burns, B. P., & Neilan, B. A. (2007) · Astrobiology · doi:10.1089/ast.2006.0097 · Cited by 147
Self-citationWang, L., Wei, D., Wei, J., & Hu, H. (2006) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2006.07.001 · Cited by 68
HPLC-DAD and Q-TOF MS Techniques Identify Cause of Daphnia Biomonitor Alarms in the River Meuse
de Hoogh, C., Wagenvoort, A. J., Jonker, F., van Leerdam, J. A., & Hogenboom, A. C. (2006) · Environmental Science & Technology · doi:10.1021/es052035a · Cited by 54
Zurita, J. L., Jos, A. M., Cameán, A. M., Salguero, M., López-Artíguez, M., & Repetto, G. (2006) · Chemosphere · doi:10.1016/j.chemosphere.2006.10.027 · Cited by 29
Cited by
Analysis and Prediction of Water Quality Using LSTM Deep Neural Networks in IoT Environment
Liu, P., Wang, J., Sangaiah, A. K., Xie, Y., & Yin, X. (2019) · Sustainability · doi:10.3390/su11072058 · Cited by 369
Wlodkowic, D., & Karpiński, T. M. (2021) · Sensors · doi:10.3390/s21217028 · Cited by 28
“There have been several developments in innovative technologies aimed at the water industries’ needs for the continuous monitoring of the chemical and physical parameters of water, including automated water sampling and remote sensors distributed in water delivery networks [6,8].”
BackgroundInfluentialLaszka, A., Abbas, W., Vorobeychik, Y., & Koutsoukos, X. (2020) · Cyber-Physical Systems · doi:10.1080/23335777.2019.1624620 · Cited by 22
“There are ongoing efforts to develop efficient remote monitoring systems for pipeline monitoring (such as PIPENET deployed at Boston Water and Sewer Commission [57,58]), water quality monitoring [59–61], leak and burst detection [62,63], and other applications, for instance [64–66].”
Background
Metadata
- Authors
- Storey, M. V., van der Gaag, B., & Burns, B. P.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 45
- Issue
- 2
- Pages
- 741-747
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W2037785537
- Cited by
- 375
- References
- 11
- FWCI
- 25.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.