Electrode passivation, faradaic efficiency, and performance enhancement strategies in electrocoagulation—a review
The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
Abstract
Treating water and wastewater is energy-intensive, and traditional methods that require large amounts of chemicals are often still used. Electrocoagulation (EC), an electrochemical treatment technology, has been proposed as a more economically and environmentally sustainable alternative. In EC, sacrificial metal electrodes are used to produce coagulant in-situ, which offers many benefits over conventional chemical coagulation. However, material precipitation on the electrodes during long term operation induces a passivating effect that decreases treatment performance and increases power requirements. Overcoming this problem is considered to be the greatest challenge facing the development of EC. In this critical review, the studies that have examined the nature of electrode passivation, and its effect on treatment performance are considered. A fundamental approach is used to examine the association between passivation and faradaic efficiency, a surrogate for EC performance. In addition, the strategies that have been proposed to remove or avoid passivation are reviewed, including aggressive ion addition, AC current operation, polarity reversal, ultrasonication, and mechanical cleaning of the electrodes. It is concluded that the success of implementing each method is dependent on critical operating parameters, and careful consideration should be taken when designing an EC system based on the phenomena discussed in this article. In conclusion, this review provides insight into passivation mechanisms, delivers guidelines for sustaining high treatment performance, and offers an outlook for the future development of EC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical technologies in wastewater treatment
Chen, G. (2004) · Separation and Purification Technology · doi:10.1016/j.seppur.2003.10.006 · Cited by 3,016
Standard Potentials in Aqueous Solution
Bard, A. J., Parsons, R., & Jordan, J. (2017) · Routledge eBooks · doi:10.1201/9780203738764 · Cited by 2,311
Standard Potentials in Aqueous Solution.
Trasatti, S. (1987) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(87)80040-5 · Cited by 1,633
Rickard, D., & Luther, G. W. (2007) · Chemical Reviews · doi:10.1021/cr0503658 · Cited by 1,599
Electrocoagulation (EC) — science and applications
Mollah, M. Y. A., Schennach, R., Parga, J. R., & Cocke, D. L. (2001) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(01)00176-5 · Cited by 1,506
Fundamentals, present and future perspectives of electrocoagulation
MOLLAH, M., MORKOVSKY, P., GOMES, J., KESMEZ, M., PARGA, J., & COCKE, D. (2004) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2004.08.009 · Cited by 1,334
A comprehensive review of electrocoagulation for water treatment: Potentials and challenges
Moussa, D. T., El-Naas, M. H., Nasser, M., & Al-Marri, M. J. (2017) · Journal of Environmental Management · doi:10.1016/j.jenvman.2016.10.032 · Cited by 963
Separation of pollutants from restaurant wastewater by electrocoagulation
Chen, X., Chen, G., & Yue, P. L. (2000) · Separation and Purification Technology · doi:10.1016/s1383-5866(99)00072-6 · Cited by 845
Garcia-Segura, S., Eiband, M. M. S. G., de Melo, J. V., & Martínez-Huitle, C. A. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.07.047 · Cited by 740
The future for electrocoagulation as a localised water treatment technology
Holt, P. K., Barton, G. W., & Mitchell, C. A. (2005) · Chemosphere · doi:10.1016/j.chemosphere.2004.10.023 · Cited by 737
Cited by
Removal of heavy metal ions from wastewater: a comprehensive and critical review
Qasem, N. A. A., Mohammed, R. H., & Lawal, D. U. (2021) · npj Clean Water · doi:10.1038/s41545-021-00127-0 · Cited by 2,225
Electrochemical Methods for Water Purification, Ion Separations, and Energy Conversion
Alkhadra, M. A., Su, X., Suss, M. E., Tian, H., Guyes, E. N., Shocron, A. N., Conforti, K. M., de Souza, J. P., Kim, N., Tedesco, M., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00396 · Cited by 661
A state-of-the-art review of the electrocoagulation technology for wastewater treatment
Boinpally, S., Kolla, A., Kainthola, J., Kodali, R., & Vemuri, J. (2023) · Water Cycle · doi:10.1016/j.watcyc.2023.01.001 · Cited by 304
Metadata
- Authors
- Ingelsson, M., Yasri, N., & Roberts, E. P. L.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 187
- Pages
- 116433
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W3087448652
- Cited by
- 342
- References
- 94
- FWCI
- 10.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.